FOR Y OUR SAFETY • Do not stor e or use g asoline or other f lammab le va pour s and liquids in the vicinity of this or an y other a ppliance. • Installa tion and ser vice m ust be perf or med b y a qualif ied installer , ser vice a g enc y or the g as supplier .
1” 1” ALCOVE INST ALLA TION LOCA TION Generally , the location selected should be as close to the wall as practical and as centralized with the piping system as possible.
– 2 – 1. COLD W A TER INLET 2. HOT W A TER OUTLET 3. GAS SUPPL Y MANUAL SHUT -OFF V AL VE 4. SEDIMENT TRAP 5. UNION - GROUND JOINT TYPE 6. FLOOR DRAIN 7. TEMPERA TURE & PRESSURE RELIEF V AL VE 8. GAS CONTROL 9. W A TER SUPPL Y T O METER 10. W A TER SUPPL Y T O HOME 1 1.
– 3 – Figure 3 - V ent Location Limit ations For a second or more direct vent unit, the dist ance between vent terminals must have a minimum of 1 foot. INSPECT SHIPMENT –– There may be hidden damage caused by transit. Check to be cert ain all p art s of the venting system, as shown in Figures 3A through 3M, are present.
SLOPE Figure 3 J Check the vent pipe’ s level or slope again, and adjust if required. – 4 – Figure 3 F Bend the 3 1/8” and 6” corrugated pipe all together toward the water heater ’ s flue connection.
– 5 – Inlet gas pressure to the appliance must not exceed the gas pressures marked on the rating plate; 7” W .C. for natural gas, 14” W .C. for L.P . gas. The minimum supply pressure for the purpose of input adjustment is 1” above manifold pressure.
– 6 – W ARNING Do not attempt to operate this water heater with the cold water inlet valve closed. Manually operate the T emperature and Pressure Relief valve at least once a year .
VI) LIGHTING AFTER INST ALLA TION W ARNING: T O A VOID POSSIBLE INJURY , FIRE AND EXPLOSION,READ THESE PRECAUTIONS BEFORE A TTEMPTING T O LIGHT OR RE- LIGHT THE PILOT . CHECK THA T THE HEA TER IS FILLED WITH W A TER AND THE VENTING SYSTEM IS UNOBSTRUCTED.
– 8 – LIGHTING INSTR UCTIONS FOR HEA TER WITH “R OBER TSHA W 220R” GAS CONTR OLS W ARNING: Should overheating occur or the gas supply fail to shut of f, turn of f the manual gas valve to the appliance. 1. ST OP! Read all safety labels on the water heater before operation.
– 9 – W ARNING If the water heater needs to be relit; 1. Open the inner door for at least 10 minutes and force some fresh air into the combustion chamber to clear any gas from the water heater and vent system. 2 Check the vent terminal for blockage.
– 10 – MAINTENANCE INSTRUCTIONS - GENERAL HOUSEKEEPING As a precaution against fire, and to maint ain an adequate flow of combustion air to the heater: • keep the appliance area clear and free f.
– 1 1 – CONTROL If the heater or the controls have been subjected to flooding, shut of f the gas at the manual shut-of f valve to the heater and call your gas comp any . The heater operates under a fully automatic control. Once the desired water temperature has been selected, the gas control will maint ain that temperature within close limit s.
See Rating Label Serial Number prefix for W arranty Code. Reduced warranty period applies to Newfoundland. W arranty Code: P R S T U V W Y S tandard W arranty Y ears: 3 5 6 7 8 9 10 12 Reduced W arran.
Een belangrijk punt na aankoop van elk apparaat GSW PART NO.70999 REV.G (03-12) (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen GSW PART NO.70999 REV.G (03-12) heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens GSW PART NO.70999 REV.G (03-12) vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding GSW PART NO.70999 REV.G (03-12) leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over GSW PART NO.70999 REV.G (03-12) krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van GSW PART NO.70999 REV.G (03-12) bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de GSW PART NO.70999 REV.G (03-12) kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met GSW PART NO.70999 REV.G (03-12) . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.