American Dr yer Corpor ation 88 Currant Road Fall River MA 02720-4781 T elephone: (508) 678-9000 / Fax: (508) 678-9447 e-mail: techsupport@amdry .com www .
ML-55 Phase 7 We have tried to make this manual as complete as possible and hope you will find it useful. ADC reserves the right to make changes from time to time, without notice or obligation, in prices, specifications, colors, and material, and to change or discontinue models.
T ab le o f Contents __________ Safety Precautions ....................................... 2 Specifications/Component Identification ..... 3 S pecifications ...................................................................... 3 Component Identification .
2 American Dryer Corp. 113345-9 S AFETY P RECA UTIONS __________ Warning For your safety, the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury, or loss of life. The dryer must never be operated with any of the back guards, outer tops, or service panels removed.
113345-9 www.amdry.com 3 MAXIMUM CAPACITY (DRY WEIGHT) 55 lb 25 kg TUMBLER DIAMETER 37” 94 cm TUMBLER DEPTH 30” 76.2 cm TUMBLER VOLUME 18.67 cu ft 0.528 cu m TUMBLER/DRIVE MOTOR 3/4 hp 0.56 kW DOOR OPENING (DIAMETER) 31-3/8” 79.7 cm WATER CONNECTION 3/4-11.
4 American Dryer Corp. 113345-9 Component Identification _____________ Dryer Front View Illus. No. Description 1 Controls 2 Control (top access) Door Assembly 3 Main Door Assembly 4 Lint Compartment Area (lint screen located behind door) 5 Data Label and Installation Label Dryer Rear View Illus.
113345-9 www.amdry.com 5 ! ! ! ! Unpacking/Setting Up _________________ Remove protective shipping material (i.e., plastic wrap, and/ or optional shipping box) from dryer. Important Dryer must be transported and handled in an upright position at all times.
6 American Dryer Corp. 113345-9 ! ! ! ! ! Note Component failure due to dry cleaning solvent fumes will void the warranty. Exhaust Requirements _________________ General Exhaust Ductwork Information Exhaust ductwork should be designed and installed by a qualified professional.
113345-9 www.amdry.com 7 ! ! ! ! Important Do not use screens, louvers, or caps on the outside opening of the exhaust ductwork. Single Dryer Venting When possible, it is suggested to provide a separate exhaust duct for each dryer.
8 American Dryer Corp. 113345-9 ! ! ! ! ! ! Important For extended ductwork runs, the cross section area of the ductwork can only be increased to an extent. When the ductwork approaches the maximum limits noted in this manual, a professional heating, ventilating, and air-conditioning (HVAC) firm should be consulted for proper venting information.
113345-9 www.amdry.com 9 For added personal safety, when possible, it is suggested that a separate ground wire (no. 18 minimum) be connected from the ground connection of the dryer to a grounded cold water pipe. Do not ground to a gas pipe or hot water pipe.
10 American Dryer Corp. 113345-9 Single-Phase Electrical Lead Connections Black + Positive White or Red + Neutral or L2 Green + Ground ! For 110V Applications For 208-230/240V Applications A ground lug is provided in the rear electrical box to connect your service ground.
113345-9 www.amdry.com 11 ! Type of Gas Manifold Pressure* In-Line Pressure Natural 3.5 inches W.C. 6.0-12.0 inches W.C. 8.7 mb 14.92 - 29.9 mb Liquid Propane 10.
12 American Dryer Corp. 113345-9 TYPE OF GAS Btu/hr Rating kcal/hr Rating Natural Liquid Propane Qty. D.M.S.* Part No. Qty. D.M.S.* Part No. 160,000 40,320 3 #29 140820 3 #48 140804 Liquid Propane Conversion Kit Part Number 881598 Shaded area is stated in metric equivalent * Drill Measurement Size (D.
113345-9 www.amdry.com 13 Operating Steam Pressure Maximum 125 psig* 861.84 kPa Heat Input (Normal Load) 4.2 Bhp Consumption (Approximate) 144.7 lbs/hr 65.7 kg/hr Shaded areas are stated in metric equivalents *The minimum operating pressure is 100 psig (689.
14 American Dryer Corp. 113345-9 Steam Damper Air Piston (Flow Control) Operation Adjustment Although the steam damper operation was tested and adjusted prior to shipping at 80 psi (5.52 bar), steam damper operation must be checked before the dryer is put into operation.
113345-9 www.amdry.com 15 ! ! ! ! Preparation For Operation/Start-Up ___ The following items should be checked before attempting to operate the dryer: • Read all “ CAUTION,” “WARNING ,” and “ DIRECTION ” labels attached to the dryer. • Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label.
16 American Dryer Corp. 113345-9 ! ! ! ! Check the electric service phase sequence (3-phase [3ø] models only). While the dryer is operating, check to see if the blower wheel (impellor/fan) is rotating in the proper direction. Looking from the front, the blower wheel (impellor/fan) should spin in the clockwise (CW) direction.
113345-9 www.amdry.com 17 W ARRANTY I NFORMA TION _______ Returning Warranty Card _____________ Before any dryer leaves the ADC factory test area, a warranty card is placed on the back side of the main door glass.
18 American Dryer Corp. 113345-9 R OUTINE M AINTENANCE ________ Cleaning ______________________________ A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer, as well as throughout the ductwork system.
113345-9 www.amdry.com 19 P ROCEDURE FOR F UNCTIONAL C HECK OF R EPLACEMENT C OMPONENTS _________________ Microprocessor Controller (Computer) Board _________________________________ Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer.
20 American Dryer Corp. 113345-9 M ANU AL R ESET B URNER H I -L IMIT I NSTRUCTIONS ________________ Phase 7 ________________________________ This dryer was manufactured with a manual reset burner Hi-Limit thermostat, which is monitored by the Phase 7 computer.
113345-9 www.amdry.com 21 Installation _____________________________ Requirements The F.S.S. must be supplied with a minimum water pipe size of 1/2” and be provided with 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) of pressure. For use of optional manual bypass, a second source with the same piping and pressure requirements is required.
22 American Dryer Corp. 113345-9 Typical Water Supply Optional Manual Bypass Provisions are made in the dryer’s F.S.S. for the installation of an optional manual bypass.
113345-9 www.amdry.com 23 System Reset _________________________ After the microprocessor determines that the situation is under control and shuts the water being injected into the basket (tumbler) off, the microprocessor display will read “ F .S.S.
ADC 113345 9 - 12/01/04-6.
Een belangrijk punt na aankoop van elk apparaat American Dryer Corp. ML-55II (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen American Dryer Corp. ML-55II heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens American Dryer Corp. ML-55II vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding American Dryer Corp. ML-55II leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over American Dryer Corp. ML-55II krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van American Dryer Corp. ML-55II bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de American Dryer Corp. ML-55II kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met American Dryer Corp. ML-55II . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.