Installation and Operating Instructions This manual describes the installation and operating procedures for the American Dynamics AD2096A Alarm Interface Unit.
The software/firmware furnished with this equipment is confidential to and is copyrighted by SENSORMATIC ELECTRONICS CORPORATION. It is not to be copied or disclosed in any manner without the express written consent of SENSORMATIC. The software/firmware is furnished to the purchaser under a license for use on a single system.
The installation of this product should be made by qualified service personnel and should conform to all local codes. QA301D ! W W W W A A A A R R R R N N N N II I I N N N N G G G G To reduce the risk of fire or shock hazard, do not expose this product to rain or moisture.
.
CONTENTS Page DESCRIPTION .............................................................................. 1 FEA TURES .................................................................................... 1 INST ALLA TION ................................
.
DESCRIPTION The AD2096A Alarm Interface Unit (AIU) is used with American Dynamics Matrix Switching Systems to provide automatic callup of a camera to a monitor when a specific alarm switch/contact input is activated. Each AD2096A AIU is set up to identify the matrix system video input and preset scenes with which it will be associated.
SETUP Three 8-position DIP switches are used for AD2096A setup. The first two switches, S1 and S2, are located on the rear panel (see Figure 1, page 1). The top switch, S1, identifies the block of 64 alarm contacts (out of a possible 1024) which are connected to the AD2096A.
CONNECTIONS Alarm Inputs Eleven 12-pin connectors are provided on the rear panel of the AD2096A for alarm inputs. A mating screw-terminal connector, below, is supplied for each rear panel connector. Each connector is labeled with an alarm number (1 - 64), an "A", and a ground symbol.
OPERATION Power Sources Power is supplied via the appended 3-wire power cord. Power consumption is approximately eight watts. The AD2096A is configured for 120VAC, 50/60Hz, primary power source. Operating power voltages must be held within the 105V and 125V range.
T ypical System Connections.
.
ABCDEFGH ON OFF ON OFF SELECT ALARM POWER C O M INPUT OUTPUT ABCDEFGH N N C O C M 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 25 26 27 28 2.
ABCDEFGH ON OFF ON OFF SELECT ALARM POWER C O M INPUT OUTPUT ABCDEFGH N N C O C M 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 25 26 27 28 2.
AD1996 AD2096A AUX START RELAY OUTPUT SELECTS ALARM GROUP # 1-64, 65-128, 129-192 etc.... NORMALLY OPEN/CLOSED POSITION FOR ALARM INPUTS 1-8, 9-16, 17-24 etc.
C-5 TYPICAL SYSTEM CONNECTIONS AD2096A TO AD2150/2350 AD2150/2350 RS232 PORTS MONITORS 12 3 4 5 123 ALARMS RELAY KEYBOARDS 23 4 5 CAMERAS CODE 120V 60Hz BWS BWS BWS BWS 2468 1 0 1 2 1 4 1 6 1 8 2 0 2 2 2 4 2 6 2 8 3 0 3 2 13579 1 1 1 3 1 5 1 7 1 9 2 1 2 3 2 5 2 7 2 9 3 1 AD2096A SELECTS ALARM GROUP # 1-64, 65-128, 129-192 etc.
TYPICAL SYSTEM CONNECTIONS Cascading Multiple AD2096A Units AD2096A AD2096A 6003-0047-02 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 TERMINAL BOX 2113-0019-01 BROWN (GRD) GREEN RED GREEN BROWN (GRD) RED TERMINAL .
241 AD2010 Switching Bay PORTS 120V 60Hz DATA LINE 12 PROG MON 12 34 56 78 9 1 0 AD1996 1 AD2010DBVL Module 12 3 4 5 6 7 8 12 3 4 5 6 7 8 DATA LINE IN OUT SYNC 120 VAC 50/60 Hz 1 17 33 49 65 81 97 113.
Index.
.
I-2 INDEX AD2096A Alarm Input Connections . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Alarm Relay Output Connection . . . . . . . . . . . . . . . . . . . . . 3 Alarm Response Operation . . . . . . . . . . . . . . . . . . . . . . . . . 4 Baud Rate Setup .
.
DECL ARA TION OF CONFORMITY According to ISO/IEC G uide 22 and EN45014 Manufacturer’s N ame: Sensormatic Electr oni cs Corporation Manufacturer’s A ddress: 1 Blue Hill Plaza 2 nd Floor Pearl River.
Sensormatic Video Systems Division One Blue Hill Plaza Pearl River, New York 10965 (845) 624-7600 Technical Support Center: 1-800-442-2225 FAX: 845-624-7685 8000-1819-01, Rev A December, 2000 Printed .
Een belangrijk punt na aankoop van elk apparaat American Dynamics AD2096A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen American Dynamics AD2096A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens American Dynamics AD2096A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding American Dynamics AD2096A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over American Dynamics AD2096A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van American Dynamics AD2096A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de American Dynamics AD2096A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met American Dynamics AD2096A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.