Gebruiksaanwijzing /service van het product AP24BC250-3 van de fabrikant American Panel
Ga naar pagina of 43
R E V . E Cooler is Better! TM USER’S MANUAL BLAST CHILLERS (SHOCK FREEZERS) MODEL AP24BC250-3 MODEL AP24BCF300-3 MODEL AP40BC350-3 MODEL AP40BCF450-3 American Panel Corporation 5800 S.E. 78th Street, Ocala, Florida 34472-3412 Phone: (352) 245-7055 Fax: (352) 245-0726 E-mail: service@americanpanel.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 1 INDEX INTRODUCTION 3 CONTROLLER FEATU RES 3 OPERATING MODES 3 AUTOMATIC MODE 3 MANUAL MODE 4 OPERATING CYCLES 4 PRINTER (OPTIONAL) 4 PC .
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 2 MANUAL SOFT CYCLE PARAME TERS PROGRAMMING 22 MANUAL HARD CYCLE PARAMETERS PROGRA MMIN G 23 MANUAL SHOCK CYC LE PARAMETERS PROGRA MMING 24 3. RECIPE NAME PROGRAMMING 25 OPERATION 26 1. AUTOMATIC MODE - SOFT CHILL 26 2.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 3 INTRODUCTION Blast Chiller Models AP24BC250-3 and AP40BC350-3 are used to rapidly chill cooked foods to temperatures suitable for refrigerated storage. They are capable of lowering the core temperature of most foods from 160 o F to 40 o F in 90 minutes.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 4 MANUAL MODE Operating time is set manually, by the operator, for the meal that has been chosen. Air temperature is controlled by the air probe. If the food probes have been inserted into the food they will provide temperature readouts only.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 5 INSTALLATION OF REMOTE UNITS REQUIREMENTS TO BE MET DURI NG INSTALLATION (8 STEPS) COMPRESSOR FIG. 1 1. Inclination of the piping. FIG. 2 2. Fastening of brackets on insulated piping. FIG.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 6 INSTALLATION AT DIFFERENT LEVELS If the remote condensing unit is installed at a higher level than the cabinet (FIG. 6) insert a siph on in the return line at every 6 ft. of difference in height.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 7 INSTALLATION WARNINGS READ ALL OF THE INSTRUCTIO NS IN THIS MANUAL BEFOR E YOU ATTEMPT TO INSTALL THE EQUIPMENT. ALWAYS DISCONNECT THE UNIT FROM THE POWER SOURCE B EFORE PERFORMIN G ANY SERVICE OR MAINTENANCE .
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 8 ELECTRICAL AND REFRIGERATION SPECIFICATIONS CABINET REMOTE CONSENSER MODEL VOLTAGE AMPS POWER SUPPLY CORD BTU/H AT 14°F EVAP. TEMP. & 105°F COND. TEMP. TYPE AP24BC250-3 208/3/60 8 14-4 25,000 MEDIUM TEMP.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 9 l. Make sure that the fans inside the cabinet rotate clockwise. m. Make sure that the cabinet has been leveled. SPACES AROUND THE CABINET • At least 15" clear space is required above the unit for service.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 10 USING THE HURRICHILL™ TECHNOLOGY BLAST CHILLING All cooked food rapidly loses its quality and aroma if it is not served promptly. Natural bacteria growth, the main reason why food becomes stale, takes place at an exponential rate between 140°F and 40°F.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 11 PANNING AND LOADING PANNING 1. Standard pan depth is 2-1/2”. Other depths can be used but are not reco mmended as their use would require an increase in the cycle time. 2. Stainless steel or aluminum pans are recommended, as plastic containers will increa se the chilling time.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 12 CONTROL PANEL FOR MODELS AP24 & AP40 BLAST CHILLERS / SHOCK FREEZERS.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 13 KEYBOARD KEYS ON/OFF & START/STOP CYCLE KEYS ON/OFF SOFT CYCLE START/STOP HARD CYCLE SHOCK CYCLE PROGRAMMING KEYS AUTOMATIC CYCLE U.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 14 PROGRAMMING 1. INITIAL PROGRAMMING NOTE: Initial programming is preset at the factory. Use this section only if changes are desired. If no changes are to be made, skip to Page 17 ( 2. Programming the cycles ).
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 15 g. To set the d ay, press or then press . 03(day) Blinks h. To set the h our, press or (be sure to continue to press the buttons until the hour and " AM" or " PM" show correctly) then press .
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 16 : The low food alarm temperature should be left at 35 o F. However, to make a change o. To change the temperature, press or then press . 35 Blinks p. To change to YES or NO , press or then press .
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 17 For YES, the display will show: The printer baud rate should be left at 1200. However, to make a change: x. To change the baud rate, press or then press . 1200 Blin ks y. To change the timing, press or then press .
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 18 AUTOMATIC SOFT CYCLE PARAMETERS PROGRAMMING The LED for "A" will be "ON" . The LED'S for cycles will be blinking. c. Press . The LED for "SOFT" will be steady "ON" .
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 19 then press . * 0 o F for shock freezers (AP24BCF3 00-3, AP40BCF450-3) 10 o F for blast chillers (A P24BC250-3, AP40BC350-3) k.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 20 A fter about 2 seconds the display will automatically change to: The LED for "A" will be "ON" . The LED'S for cycles will be blinking. r. Press the button (for shock freezers only).
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 21 y. To change the time, press or then press . 00:30 Blinks The display will show: PARAM.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 22 ee. To change the time, press or then press . 05 Blinks The display will show: PARAM. PROGRA MMING HEATED PROBE CYCLE HEATING TIME 05 SEC PARAM.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 23 The display will show: PARAM. PROGRA MMING MANUAL SOFT CYCLE PROGRAMMING COMPLETE MANUAL HARD CYCLE PARA METERS PROGRAMMING A fter about 2 seconds the display will automatically change to: The LED for "M" will be "ON" .
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 24 tt. To change the temperature, press or then press . 35 Blinks uu. To change the temperature, press or then press . 42 Blinks The display will show: PARAM. PROGRA MMING MANUAL HARD CYCLE HOLDING LOW TEMP.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 25 The display will show: A fter about 2 seconds the display will automatically change to: PARAM.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 26 OPERATION 1. AUTOMATIC MODE - SOFT CHILL a. With the display reading "OFF" , press the ( “ON/OFF” ) button. b. To select th e soft cycle, press the appropriate button . The LED for "SOFT" will be steady "ON" .
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 27 alt alt The display will show: ernating with ernating with h. Press the (" START/STOP" ) button to start the cycle. PRESS START Blinks The display will show briefly: Then the display will show: READY TO START PRESS START 03.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 28 F INSTEAD OF AUTOMATIC you wish to select a MANUAL cycle, perform steps 1.a, 1.b, 1.c, 1.d, 1.e, 1f and 1.g (above), except in step 1.c press button instead of button . The in tho LED for "MANUAL" will then be steady "ON".
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 29 ow steps 1 or 2 (above), EXCEPT in step 1.b (above) press To perform a hard chill cycle, foll instead of . . SHOCK FREEZE CYCLE w steps 1 or 2 (above), EXCEPT in step 1.b (above) press 4 To perform a shock freeze cycle, follo instead of .
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 30 aporator fan for 5 minutes with the door open. rost cycle, press the The defrost cycle runs the ev a. To perform a def ( "DEFROST" ) button. b. Open the door. OPERATING MODE CHOOSE OPERATING CYCLE c.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 31 To select the heated food probe, press a. ("HEATED PROBE"). If the food probe temperature is over 30 o F, the display will sh.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 32 With the display reading "OFF" , press the a. ( “PRINT” ) button. b. To start printing, press the ( "START/STOP") button. OFF PRINT EVENTS MEMORY READINGS LEFT 249 After a few seconds the display will show: nd the printer will be printing.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 33 LOADING A ROLL OF PAPER atterns to pop the front edge up. Lift off he light will go off. 3. Unroll several inches of paper. he slot connecting the paper partment. It can be slid in about 1/4” before it stops.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 34 2. f the printer cover. Push down on one or letely off. move the r t the ribbon cartridge if there is already paper in the printer.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 35 or correct and efficient operation of the blast ch iller, it is necessary that the condenser be kept ely and come into contact with the whole of its surface. OTE: If additional refrigerant should be needed, be certain to use the ct e an mount as shown on the nameplate.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 36.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 37.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 38.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 39 COMPUTER CONNECTION.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 40 PARTS LIST PART # DESCRIPTION 990059 PRINTER 990060 RELAY 10 A FINDER (UV) 990074 TRANSFORMER 208V/24V/12V 990075 TRANSFORMER F OR PRIN.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 41 STANDARD WARRANTY AMERICAN PANEL CORP. 5800 S.E. 78th Street, Ocala, Florida 34472-3412 American Panel Corporation products are warrant.
AP24BC250-3, AP24BCF300-3, AP40BC350-3, AP4 0BCF4 50-3 Manual 42 ORDERING PRINTER SUPPLIES (RIBBON & PAPER) Replacement paper and ribbons for the optional printe r for your blast chiller can be ordered from a local distributor of Weigh-Tronix supplies.
Een belangrijk punt na aankoop van elk apparaat American Panel AP24BC250-3 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen American Panel AP24BC250-3 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens American Panel AP24BC250-3 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding American Panel AP24BC250-3 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over American Panel AP24BC250-3 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van American Panel AP24BC250-3 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de American Panel AP24BC250-3 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met American Panel AP24BC250-3 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.