Gebruiksaanwijzing /service van het product ShowerArc 26396001 van de fabrikant Hans Grohe
Ga naar pagina of 32
ShowerArc 26396001 Installation Instructions / W arranty.
2 ShowerArc 26396001 Minimum ceiling height – 90 1/2”.
3 For best results, Hansgrohe recommends that this unit be installed by a licensed, professional plumber . Please read over these instructions thor- oughly before beginning installation. Make sure that you have all tools and sup- plies needed to complete the installation.
4 Installation in 90º corner: Instructions begin on page 5 W all-to-wall installation Requires 26397000 installation kit (included): Instructions begin on page 13.
5 Only one set of supplies is required – do not install two sets of supplies . Installation in 90º corner The thermostatic mixing valve may be installed on either wall.
6 Installation in 90º Corner Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4.
7 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8.
8 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 9 10 11 12 6 mm.
9 13 14 15 16.
10 1 2 17 18 19 20 6 mm.
11 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 21 22 23 24 6 mm.
12 T urn to page 22 to continue the installation. Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage.
13 The thermostatic mixing valve may be installed on either wall. The diagram shows both possible positions for the installation. Only one set of supplies is required – do not install two sets of supplies .
14 W all-to-W all Installation Seal the wall around the supplies with waterproof sealant. Failure to seal the wall can lead to possible water damage. 1 2 3 4.
15 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. 5 6 7 8.
16 Seal the wall around the anchors with waterproof sealant. Failure to seal the wall can lead to possible water damage. Be careful not to drill into water lines! 1 2 6 mm 12 9 10 11.
17 Install the 26397000 mounting set 13 14 15 16.
18 XX 90 XX = 17 18 19 20.
19 6 mm SW 3 mm M6x8 1 2 24 21 22 23.
20 Install the 26397000 mounting set M6x60 1. 2. 3. SW 3 mm M6x8 25 26 27 6 mm 28 Seal the wall around the an- chors with waterproof sealant. Failure to seal the wall can lead to possible water damage.
21 T urn to page 22 to continue the installation. SW 3 mm M6x8 29.
22 Install the Cover , Escutcheon, and Handle Install the Showerhead and Handshower 2 1.
23 Reset the High T emperature Limit Stop Loosen the handle screw with a 3 mm Allen wrench. Remove the retainer clip and stop ring from the stem. T ur n the stop unit to the handshower position. T ur n the temperature control stem until the output water is the desired high temperature -- usually 110º.
24 T ur n the stop unit to the off position. Install the stop ring so that the tooth is against the stop. Install the clip. Install the handle. T ighten the handle screw with a 3 mm Allen wrench.
25 Justify the Handle T ur n the diverter handle to the handshower position. T ur n the temperature control knob until the output water is 100ºF . T ur n the diverter handle to the off position. Loosen the handle screw with a 3 mm Allen wrench. Remove the handle.
26 User Instructions Using the Handshower T ur n the function lever to until the desired spray mode has been obtained. T ur n the temperature control knob to change the tem- perature. T ur n it clockwise to make the water cooler , counter-clockwise to make the water warmer .
27 If necessar y , pour about 3/4” of a commercial scale remover , such as Lime-A way or CLR, into a shallow dish. Soak the spray face for the amount of time shown in the label instructions. Rinse the spray face with clear water . Reinstall the handshower .
28 Replacement Parts 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 17 25.
29 1 wall flange 96768000 2 escutcheon 96767000 3 branch connection 97496000 4 branch connection 97497000 5 shower hose 28276000 6 handshower 28504001 7 handshower holder 28321000 8 body spray 9760300.
30 Problem Possible Cause Solution Unit outputs both hot and cold water , but it does not mix not a product defect -- the hot and cold supplies are reversed correct the plumbing W ater temperature doe.
31 Limited Lifetime Consumer W arranty This product has been manufactured and tested to the highest quality standards by Hansgrohe, Inc. (“Hansgrohe”). This warranty is limited to Hansgrohe products which are purchased by a consumer in the United States after March 1, 1996, and installed in either the United States or Canada.
Hansgrohe, Inc. • 1490 Bluegrass Lakes Parkway • Alpharetta, GA 30004 T el. 770-360-9880 • Fax 770-360-9887 www .hansgrohe-usa.com US - Installation Instructions • Part No.
Een belangrijk punt na aankoop van elk apparaat Hans Grohe ShowerArc 26396001 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hans Grohe ShowerArc 26396001 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hans Grohe ShowerArc 26396001 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hans Grohe ShowerArc 26396001 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hans Grohe ShowerArc 26396001 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hans Grohe ShowerArc 26396001 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hans Grohe ShowerArc 26396001 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hans Grohe ShowerArc 26396001 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.