R1 P61A-2 ! Pellet ! S tove ! Owners ! Manual SA VE ! THESE ! INSTRUCTIONS. Inst allation ! & ! Operating ! Manual R5 ìCe ! manuel ! est ! disponible ! en ! FranÁais ! sur ! demandeî SAFETY ! NOTICE PLEASE ! READ ! THIS ! ENTIRE ! MANUAL ! BEFORE ! YOU ! INST ALL ! AND ! USE ! YOUR ! NEW ! ROOM ! HEA TER.
2 P61A !! Pellet ! Stove Fig. ! 1.
3 P61A ! Pellet ! Stove T esting ! Lable 2 Assembly ! & ! Installation 4 Installation 5 V enting !!!!!!!!!! 6 Automatic ! Operation 1 2 ESP ! Control 1 6 Maintenance 1 7 T rouble ! Shooting 2 2 Fe.
4 P61A !! Pellet ! Stove !!!!! ! ! Assembly ! and ! Installation Unpacking The ! P61 ! is ! bolted ! to ! the ! skid ! to ! prevent ! movement during ! shipping. To ! free ! the ! stove ! from ! the ! skid ! you ! must ! remove the ! hold-down ! bolts ! in ! the ! rear ! of ! the ! pedestal ! base.
5 P61A ! Pellet ! Stove Installing Place ! the ! stove ! on ! a ! noncombustible ! floor ! protector that ! extends ! 6 ! inches ! to ! the ! front, ! 6 ! inches ! to ! the ! sides and ! 1 ! inch ! to ! the ! rear ! of ! the ! stove. ! The ! minimum ! floor protector ! material ! is ! 24 ! gauge ! sheet ! metal.
6 P61A !! Pellet ! Stove V enting Requirement s ! for ! T erminating ! the ! V enting W ARNING: ! V enting ! terminals ! must ! not ! be ! re- cessed ! into ! a ! wall ! or ! siding. NOTE: ! Only ! PL ! vent ! pipe ! wall ! pass-throughs and ! fire ! stops ! should ! be ! used ! when ! venting ! through combustible ! materials.
7 P61A ! Pellet ! Stove V enting A ! combustion ! blower ! is ! used ! to ! extract ! the ! com- bustion ! gases ! from ! the ! firebox. ! This ! causes ! a ! negative pressure ! in ! the ! firebox ! and ! a ! positive ! pressure ! in ! the venting ! system ! as ! shown ! in ! fig.
8 P61A !! Pellet ! Stove #2 ! Preferred ! method This ! method ! also ! provides ! excellent ! venting ! for normal ! operation ! but ! requires ! the ! stove ! to ! be ! installed farther ! from ! the ! wall.
9 P61A ! Pellet ! Stove #4 ! Installing ! into ! an ! existing chimney ! ( ! US ! only ! ) This ! method ! provides ! excellent ! venting ! for ! normal operation. !! This ! method ! also ! provides ! natural ! draft ! in the ! event ! of ! a ! power ! failure.
10 P61A !! Pellet ! Stove #6 ! Installing ! into ! an ! existing fireplace ! chimney ! ( ! US ! and Canada ! ) This ! method ! provides ! excellent ! venting ! for ! normal operation. !! This ! method ! also ! provides ! natural ! draft ! in the ! event ! of ! a ! power ! failure.
11 P61A ! Pellet ! Stove #8 ! Installing ! through ! the ! ceiling ! vent Through ! the ! ceiling ! vent, ! follow ! PLvent manufacturers ! recommendations ! when ! using ! wall ! and ceiling ! pass ! through. Fig. ! 14 No ! insulation ! or other ! combustible materials ! are allowed ! within ! 3" of ! the ! PL ! vent ! pipe.
12 P61A !! Pellet ! Stove The ! P61A ! pellet ! stove ! is ! more ! than ! just ! automatic ! ignition, ! it ! is ! also ! automatic ! temperature ! control. The ! automatic ! system ! will ! allow ! the ! fire ! size ! to ! be ! adjusted ! to ! match ! the ! heating ! needs ! and ! even ! put the ! fire ! out ! if ! necessary .
13 P61A ! Pellet ! Stove Starting ! First ! Fire Ignitor ! Switch ! to"AUTO"(up ! position) Make ! sure ! the ! unit ! is ! plugged ! into ! a ! 120 V AC, ! 60 ! HZ ! electrical ! source. ! The ! power ! light should ! be ! the ! only ! light ! lit.
14 P61A !! Pellet ! Stove The ! P61A ! Pellet ! Stove ! is ! capable ! of ! manual ! operation. ! This ! also ! allows ! the ! operator ! to manually ! control ! operation ! during ! an ! emergency ! (i.e. ! ignitor ! failure, ! when ! using ! a ! 502H ! battery backup, ! or ! when ! using ! certain ! generators.
15 P61A ! Pellet ! Stove P61A-2 !! MANUAL !! ST ART !! UP Starting ! First ! Fire Ignitor ! Switch ! to"MANUAL" (down ! position) Make ! sure ! the ! unit ! is ! plugged ! into ! a 120 ! V AC, ! 60 ! HZ ! electrical ! source. ! The power ! light ! should ! be ! the ! only ! light ! lit.
16 P61A !! Pellet ! Stove O O P61A-2 !! AUTOMA TIC ! IGNITION !! ESP !! CONTROL Feed ! adjuster Sets ! the ! maximum ! feed rate T est Runs ! all ! motors ! at ! full speed ! for ! one ! minute to ! check ! operation.
17 P61A ! Pellet ! Stove These ! units ! are ! pre-tested ! at ! the ! factory ! with ! exactly 120 ! V olts ! A.C., ! 60 ! Hz. ! They ! are ! checked ! and ! adjusted !! for firebox ! tightness, ! gasket ! leakage, ! motor ! operation ! and ! ignitor operation.
18 P61A !! Pellet ! Stove The ! room ! sensor ! is ! a ! small ! temperature ! sen- sor ! on ! the ! end ! of ! a ! 60" ! gray ! wire. ! This ! sensor ! is installed ! much ! like ! a ! standard ! wall ! thermostat.
19 P61A ! Pellet ! Stove Removing ! Ashes: When ! approximatly ! 1 ! ton ! of ! pellets ! has ! been burned ! it ! will ! be ! necessary ! to ! empty ! the ! ash ! pan. Ashes ! should ! be ! placed ! in ! a ! metal ! container with ! a ! tight ! fitting ! lid.
20 P61A !! Pellet ! Stove Latch ! "closed ! "with blower ! cover ! in ! place. Burn ! pot ! clean-out ! is closed. Latch ! "open ! "with ! blower cover ! partly ! removed. Burn ! pot ! clean-out ! is open. Exposed !! blower ! wheel and ! flue ! opening, NOTE: ! ESP ! probe ! is visible.
21 P61A ! Pellet ! Stove Burn ! Pot ! Cleaning ! and ! Maintenance 1. !! Scrape ! the ! top ! holed ! surface ! and ! sides ! of ! the ! burn pot.(Fig !! 34) ! It ! is ! not ! necessary ! to ! completely ! remove all ! material ! from ! the ! burn ! pot.
22 P61A !! Pellet ! Stove !! FEEDER ! DOES ! NOT ! FEED 1. ! No ! pellets ! in ! hopper . 2. ! Firebox ! draft ! may ! be ! too ! low ! for ! low ! draft ! pressure switch ! in ! feeder ! circuit ! to ! operate. ! Check ! for ! closed doors , ! loose ! or ! missing ! gasket ! on ! doors ! or ! hopper ! lid, faulty ! pressure ! switch.
23 P61A ! Pellet ! Stove W eight 24 9 ! lbs. Blower 13 5 ! cfm Feed ! Rate .75 ! to ! 7.5 ! lbs. ! per ! hr . Hopper ! Capacity 7 2 ! lbs. Fuel W o od ! Pellets Flue ! Size 3 ! inch Outside ! Air ! Size 2 ! 3/8 ! I.D. ! inch Fuse ! Rating 5 ! amp 32.375" 9" 23.
24 P61A !! Pellet ! Stove Door ! Options Optional ! T rim To ! install, ! lay ! the ! frame ! face ! down ! on ! a ! sof t surface. !! Fasten ! door ! frame ! by ! inserting ! the ! 4 threaded ! post s ! on ! the ! frame ! through ! the ! door .
25 P61A ! Pellet ! Stove OPTIONS Side ! Heat ! Shields Side ! heat ! shields ! are ! available ! to ! reduce the ! clearance ! to ! combustible ! materials. Hopper ! Extension The ! hopper ! extension ! allows ! you ! to put ! more ! pellet ! fuel ! in ! the ! hopper ! and ! extends burn ! time ! on ! one ! load ! of ! pellets.
26 P61A !! Pellet ! Stove P61A-2 ! Wiring ! Diagram.
27 P61A ! Pellet ! Stove Description Part ! Number Hopper ! Gasket(6 ! ft.) 0-88-00248 Ash ! Pan ! Assembly 1-10-05800 Burn ! Pot ! Weldment 1-10-05802 Right ! Rear ! Shield 2-00-06468-1 Left ! Rear !.
28 P61A !! Pellet ! Stove Harman ! S tove ! Company ! warrants ! its ! products ! to ! be ! free ! from ! defects ! in ! material ! or ! workmanship, ! in ! normal ! use and ! service, ! for ! a ! per.
Een belangrijk punt na aankoop van elk apparaat Harman Stove Company P61A-2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Harman Stove Company P61A-2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Harman Stove Company P61A-2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Harman Stove Company P61A-2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Harman Stove Company P61A-2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Harman Stove Company P61A-2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Harman Stove Company P61A-2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Harman Stove Company P61A-2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.