1 R1 SAFETY NOTICE PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INST ALL AND USE YOUR HEA TING APPLIANCE. F AILURE TO FOLLOW INSTRUCTIONS MA Y RESUL T IN PROPERTY DAMAGE, BODIL Y INJUR Y , OR EVEN DEA TH.
2 T able of Contents Packing List 3 Installation 5 Mounting Blower & Filter Box 7 Wiring 8 Duct Work 1 1 Operation 1 1 Safety T ips 13 Chimney T roubleshooting 13 Maintenance 14 Specications.
3 Packing List - SF2600 Blue Angel Oil Burner Burner Gasket Automatic Draft Control Blower (2) Blower Brackets Filter Box Kit (3 pieces) + Filter Fan Control / High Limit 3-Speed Fan Switch (not on SF.
4 Packing List for SF1500, SF2500 & SF3500 Blower Mounting Plate w/ 2= 5/16X3/4 bolts ( SF3500 Only) Automatic Draft Control Blower (2) Blower Brackets Filter Box Kit (3 pieces) + Filter Fan Contr.
5 T o ensure a safe installation, it is recommended that this furnace be installed by a qualied installer . The sheet metal top and sides can be easily removed to reduce the chance of dents or scratches on the painted surfaces. T oremovethesheetmetal,rstliftoffthetop section.
6 Bolt the auto- matic draft control to the bottom door . Be sure to hold the unit straight while tighten- ing. After the auto- matic draft control is mounted, the two wires must be strung throughtheexible conduitandtwottings supplied.
7 SF2600. ThisgurerepresentsthemodelSF2600furnace.It’sintentionisto represent the approximate location of the various controls. This draw- ing may also be used as a reference for wiring and control spacing. Pleasenotethatthisdrawingisforreferenceonly .
8 Furnace Installation - Wiring Wiring Beforebeginninganywiring,studytheappropriatewiringdiagramforyourunit. Alsoreferbacktog - ures C or D for an example of what the completed job will look like.
9 SF3500 Wiring Diagram SF3500 Wiring Diagram.
10 SF2600 Wiring Diagram SF2600 Wiring Diagram.
1 1 Duct W ork and Operating Instructions Duct Work. Thisgureshowsatypicalduct system layout. Be sure the entire sys- tem is properly sized to provide the cor- rect static pressure for optimum blower performance. Have any new duct sys- tem designed by a HV AC professional.
12 SF 2600 - Oil Operation as Backup - The SF 2600 offers a unique option to the homeowner . Theability tohave anefcient oilbackup heatsource built right into a wood/coal furnace. The operation of the oil burner as a backup system is as simple as setting a thermostat.
13 The amount of shaking is critical. T oo much will disrupt the rebedandtoolittlewillrestricttheairow . The properamount normallyoccurs when redcoals rst start to drop through the grates into the ash pan.
14 Maintenance The spiral chamber is basically self-cleaning. However , if there is a draft problem and you have been burning wood for a long time with little heat demand, the spiral chamber may need cleaning. Soft coal will also require more frequent cleaning.
Specications SF1500 SF2500 SF2600 SF3500 Complete Complete Complete Complete Heating Capacity- square ft. 2200 3200 3200 4200 Approximate BTU Input 90,000 120,000 120,000 170,000 Blower Size 1000 c.
16 Special Instructions Hot W ater Out Cold W ater In Pressure Relief V alve Existing W ater Heater Rear Of Furnace Automatic Air V alve Pressure Relief V alve (Must be within 2 feet of coil) 10 Feet .
17 Special Instructions 1 2 3 3 4 5 6 7 8 Hot Water Out Cold Water In T emp. / Pressure Relief V alve Aquastat, close on rise. Optional Automatic Air V alve Pressure Relief V alve - Must be within 2 ft.
18 SF2600 Burner Set Up 7” 12½” 7¾” 12⅞” SF2600 Oil Burner Setup Nozzle 80 Degree Solid Cone Off Cycle Damper Setting (B) No.1 (as low as it goes Flamelock Setting (A) No. 1 Combustion Air (C) No. 1 to 1¼ Draft - (Inches of water column) .
W arranties are not transferable. Harman Stove Company warrants its products to be free from defects in material and workmanship, in normal use and service, for ve (5) years from the date of sales invoice.
20.
Een belangrijk punt na aankoop van elk apparaat Harman Stove Company SF 3500A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Harman Stove Company SF 3500A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Harman Stove Company SF 3500A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Harman Stove Company SF 3500A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Harman Stove Company SF 3500A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Harman Stove Company SF 3500A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Harman Stove Company SF 3500A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Harman Stove Company SF 3500A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.