Gebruiksaanwijzing /service van het product PIER-36TR-IPI van de fabrikant Heat & Glo LifeStyle
Ga naar pagina of 85
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 1 Models: ST -36TR-IPI ST -36TRLP-IPI PIER-36TR-IPI PIER-36TRLP-IPI • DO NOT store or use gasoline or other fl am- mable vapors and liquids in the vicinity of this or any other appliance.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 2 Listing Label Information/Location Model Name: ___________________________________________ Date purchased/installed: ___.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 3 Safety Alert Key: • DANGER! Indicates a hazardous situation which, if not avoided will result in death or serious injury . • W ARNING! Indicates a hazardous situation which, if not avoided could result in death or serious injury .
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 4 = Contains updated information. 13 Finishing A. Splatter Guard . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57 B. Mantel and Wall Projections . . .
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 5 B. Limited Lifetime W arranty 4021-645C 12-29-10 Page 1 of 2 Hearth & Home T echnologies Inc.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 6 B. Limited Lifetime W arranty (continued) 4021-645C 12-29-10 Page 2 of 2 W ARRANTY CONDITIONS: 7KLVZDUUDQWR.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 7 B. T empered Glass Speci fi cations Hearth & Home T echnologies appliances manufactured with tempered glass may be installed in hazardous loca- tions such as bathtub enclosures as de fi ned by the Con- sumer Product Safety Commission (CPSC).
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 8 H. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment install.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 9 2 2 Operat ing Instruc tions Figure 2.1 General Operating Parts B. Y our Fireplace W ARNING! DO NOT operate fi replace before read- ing and understanding operating instructions.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 10 D. Clear Space W ARNING! DO NOT place combustible objects in front of the fi replace or block louvers. High temperatures may start a fi re. See Figure 2.3. Avoid placing candles and other heat-sensitive objects on mantel or hearth.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 1 1 I. Lighting Instructions (IPI) The IPI system may be operated with two D-cell batteries. T o prolong battery life, remove them when using the transformer . 1. This appliance is equipped with an ignition device which automatically lights the burner.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 12 Initial Break-in Procedure • The fireplace should be run three to four hours continuously on high. • T urn the fi replace of f and allow it to completely cool. • Remove fi xed glass assembly .
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 13 Glass Cleaning Frequency: Seasonally By: Homeowner T ools Needed : Protective gloves, glass cleaner , drop cloth and a stable work surface. CAUTION! Handle fi xed glass assembly with care.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 14 B. Maintenance T asks-Quali fi ed Service T echnician The following tasks must be performed by a quali fi ed ser- vice technician.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 15 Figure 3.4 IPI Pilot Flame Patterns Burner Ignition and Operation Frequency: Annually By: Quali fi ed Service T echnician T ools needed: Protective gloves, vacuum cleaner , whisk broom, fl ashlight, voltmeter , indexed drill bit set, and a manometer .
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 16 A. T ypical Appliance System NOTICE: Illustrations and photos re fl ect typical installations and are for design purposes only . Illustrations/diagrams are not drawn to scale.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 17 B. Design and Installation Considerations Heat & Glo direct vent gas appliances are designed to operate with all combustion air siphoned from outside of the building and all exhaust gases expelled to the outside.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 18 5 5 F raming and Clearances A. Selecting Appliance Location When selecting a location for the appliance it is important to consider the required clearances to walls (see Figure 5.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 19 C A B D B. Constructing the Appliance Chase A chase is a vertical box-like structure built to enclose the gas appliance and/or its vent system. In cooler climates the vent should be enclosed inside the chase.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 20 C A B D Figure 5.3 Clearances to Combustibles PIER-36TR-IPI G F I I E H * Adjust framing dimensions for interior sheath.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 21 Note: All measurements in inches. MEASUREMENT S FROM TOP EDGE OF T HE OPENING 5 10 11 12 2-1/2 13 14 15 16 17 18 19 32 TO CEILI NG 9 10 11 12 8 7 6 5 4 3 25 18 See-Through Combustible Mantel PIER Combustible Mantel Note: All measurements in inches.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 22 TOP VIEW 3-1/4 in. Min. 2-3/4 in. Min. 1/2 in. Min. Unlimited 1 in. Max. FIREPLACE OPENING Note: Clearance from opening to perpendicular wall. Figure 5.10 Non-Combustible Zone Figure 5.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 23 A. V ent T ermination Minimum Clearances Roof Pitch H (Min.) Ft. Flat to 6/12...........................................................1.0* Over 6/12 to 7/12 ...........
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 24 Figure 6.3 Minimum Clearances for T ermination O N P R Q X = AIR SUPPL Y INLET A = 12 inches................. clearances above grade, veranda, porch, deck or balcony B = 12 inches.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 25 B. Continue Adding V ent Components T o Install the Heat Shield: 1. Determine if the heat shield is required. Do so by measuring the vertical distance between the top horizontal surface of the elbow to any combustible surface above.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 26 A. Approved Pipe This appliance is approved for use with Hearth & Home T echnologies a DVP venting system. Refer to Section 16B for vent component information. DO NOT mix pipe, fi ttings or joining methods from differ- ent manufacturers.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 27 T o replace the fi rst starter elbow with two 45° elbows, refer to Figure 7.3. All other 90° elbows can be replaced with two 45° elbows. General Rules: • A maximum of three 90° elbows (or six 45° elbows) may be used in any vent con fi guration.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 28 H 1 V 1 Figure 7.4 Figure 7.5 One Elbow T wo Elbows INST ALLED HORIZONT ALL Y H 1 H 2 V 1 1. T op V ent - Horizontal T ermination - (continued) V 1 Minimum H 1 Maximum Elbow only 1-1/2 ft.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 29 Figure 7.6 1. T op V ent - Horizontal T ermination - (continued) Three Elbows V 1 Minimum H 1 Maximum V 2 Minimum H 2 Maximum V 1 + V 2 Minimum H 1 + H 2 Maximum Elbow only 1 ft.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 30 Refractory Panel T o access the exhaust opening, remove the refractory panel and exhaust baffle. T o remove refractory panel, remove the two screws on top. To remove the exhaust baffle, remove the three screws securing it.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 31 Figure 7.10 4. Center the exhaust restrictor in the open end of the ex- haust outlet and secure through the slots on the exhaust restrictor with the 2-1/4 in. self tapping screws provided in the appliance manual bag.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 32 V 1 H 1 Maximum V 2 V 1 + V 2 Minimum One Elbow 2-1/2 ft. 762 mm * * * 2 ft. 607 mm 6 ft. 1.8 m * * * 4 ft. 1.2 m 12 ft. 3.7 m * * * 6 ft. 1.8 m 18 ft. 5.5 m V 1 + V 2 + H 1 = 50 ft (15.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 33 3. Rear V ent - Horizontal T ermination Figure 7.13 Figure 7.14 No Elbow One 45° Elbow H 1 = 16 in. (406 mm) Maximum H 1 H 1 DO NOT use a 45º elbow in corner installations.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 34 INSTALLED HORIZONTALLY H 3 H 2 V 1 H 1 3. Rear V ent - Horizontal T ermination - (continued) T wo Elbows Figure 7.15 Figure 7.16 Three Elbows H 2 V 1 H 1 H 1 Maximum V 1 Minimum H 2 Maximum H 1 + H 2 Maximum 1 ft.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 35 4. Rear V ent - V ertical T ermination One Elbow Figure 7.17 T wo Elbows Figure 7.18 V 1 H 1 INST ALLED HORIZONT ALL Y H 2 V 2 H 1 V 1 Minimum H 1 Maximum 1 ft. 305 mm 3 ft.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 36 4. Rear V ent - V ertical T ermination - (continued) Three Elbows Figure 7.19 Three Elbows Figure 7.20 INST ALLED HORIZONT ALL Y H 3 H 2 V 1 H 1 V 2 V 1 H 2 H 1 H 1 H 2 H 3 V 1 Minimum H 1 + H 2 + H 3 Maximum *** 8 ft.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 37 A. Pipe Clearances to Combustibles W ARNING! Risk of Fire! Maintain air space clearance to vent.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 38 C. V ertical Penetration Framing Figure 8.3 Figure 8.4 Installing the Attic Shield 3 F ASTENERS PER SIDE INSTALL ATTIC .
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 39 D. Install Attic Insulation Shield W ARNING! Fire Risk. DO NOT allow loose materials or insulation to touch vent. Hearth & Home T echnologies Inc. requires the use of an attic shield.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 40 CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp. NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 41 B. Rear V ent NOTICE: Once appliance is set up for top or rear venting, it CANNOT be changed at a later time. NOTICE: Once the vent cap has been removed it CANNOT be reattached.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 42 C. Securing and Leveling the Appliance W ARNING! Risk of Fire! Prevent contact with: • Sagging or loose insulation • Insulation backing or plastic • Framing and other combustible materials Block openings into the chase to prevent entry of blown- in insulation.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 43 1 0 10 Inst alling V ent Pi p e ( DVP and S LP P ip e ) A. Assemble V ent Sections (DVP Pipe Only) Attach V ent to the Firebox Assembly Note: The end of the pipe sec tions wi t h the lanced tabs wi ll face toward the appliance.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 44 B. Assemble V ent Sections (SLP Pipe Only) T o attach the fi rst vent component to the starting collars of the appliance: • Attach a DVP-2SL adapter to the starting collar of the appliance.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 45 120º Figure 10.8 Securing V ertical Pipe Sections 120º Figure 10.9 Securing Horizontal Pipe Sections E. Disassemble V ent Sections • Rotate either section (see Figure 10.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 46 F . Install Decorative Ceiling Components (SLP only) A decorative ceiling thimble can be installed on a fl at ceil- ing through which the vent passes. The decorative ceiling thimble is used to cover the fi restop.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 47 G. Install Metal Roof Flashing • See minimum vent heights for various pitched roofs (Figure 10.14) to determine the length of pipe to extend through the roof. • Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 48 SCREWS CAULK STORM COLLAR (1 of 3) Figure 10.18 Figure 10.18 TERMINA TION CAP I.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 49 Cap Speci fi cation Chart (depth without using additional pipe sections) 36 inch Multisided Series DVP-TRAPK1 T op V ent Depth DVP-TRAP1 Rear V ent Depth DVP-TRAPK2 T op V ent Depth DVP-TRAP2 Rear V ent Depth 2-7/8 in to 4-3/4 in 3-1/8 in.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 50 A. Fuel Conversion • Make sure the appliance is compatible with available gas types. • Conversions must be made by a qualified service technician using Hearth & Home T echnologies speci fi ed and approved parts.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 51 A. Wiring Requirements NOTICE: This appliance must be electrically wired and grounded in accordance with local codes or , in the absence of local codes, with National Electric Code ANSI/NFP A 70-latest edition or the Canadian Electric Code CSA C22.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 52 E. WSK-ML T Multifunction W all Switch The WSK-ML T multifunctional wall switch is designed to control fl ame height, blower speed and auxilary func- tions on your gas fi replace.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 53 Wiring the W all Switch • Install the provided control wire from the fi replace to the switch location. (Control wire for Heatilator products is supplied with the fi replace).
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 54 GAS CONTROL VA LV E V ARIABLE REGULA TOR FLAME CONTROL SOLENOID W ASHER V ARIABLE REGULA TOR V ARIABLE REGULA TOR W ASHER PLUNGER JAM NUT NUT SCREW KNOB SOLENOID Figure 12.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 55 I. Setting Flame Height/Manifold Pressure (T o be done by a quali fi ed service technician.) Upon initial power-up of this device, valve pressure must be set for fl ame adjustment.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 56 Cold Climate Button • Button Press: T urns on Climate Control • Button Press: T urns off Climate Control This allows the pilot fl ame to stay lit when activated. A bene fi t of this is reduced condensation on the glass at start-up in colder climate conditions.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 57 1 3 13 Fi nishing A. Splatter Guard The splatter guard is a piece of corrugated material used to protect the appliance during the installation process be- fore fi nishing work on the whole hearth is complete.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 58 Step 5. Fold bottom fl ap along score line as indicated in Figure 13.6 and tuck into valve access area of appliance. Splatter guard should fi t securely on front of unit.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 59 Note: All measurements in inches. MEASUREMENT S FROM TOP EDGE OF T HE OPENING 5 10 11 12 2-1/2 13 14 15 16 17 18 19 32 TO CEILI NG 9 10 11 12 8 7 6 5 4 3 25 18 Note: All measurements in inches.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 60 Figure 13.16 Combustible Mantel Leg or W all Projections (Acceptable on both sides of opening) TOP VIEW 2-3/4 in. Min. 1/2 in. Min. Unlimited 1 in. Max. FIREPLACE OPENING Note: Clearance from opening to perpendicular wall.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 61 Figure 13.19 Overlap Fit Door Figure 13.18 Folio Door and Aero Figure 13.20 Inside Fit Door DOOR FIT FINISH MA TERIAL MAXIMUM THICKNESS SEE FIGURE Aero Inside Any 13.18 Folio Inside Any 13.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 62 Figure 13.22 Pier Door Finishing 33-5/8 in. 37-1/4 in. FINISHING MA TERIAL.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 63 E. Elevated Hearth Systems Use the table below to identify the hearth system that will be used. The table will also help identify ef fects on the various dimensions. Some hearth systems will elevate the appliance off the fl oor at a given dimension.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 64 A. Remove Fixed Glass Assembly See Section 14G. B. Remove the Shipping Materials Remove shipping materials from inside or underneath the fi rebox.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 65 W ARNING! Risk of Explosion! Follow ember placement instructions in manual. DO NOT place embers directly over burner ports. Replace ember material annually . Improperly placed embers interfere with proper burner operation.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 66 F . Install the Log Assembly 2005-937F 9/08 Log Set Assembly: LOGS-MSR Models: PIER-HV , ST -HV , LCOR-HV , RCOR-HV ST -36TR, PIER-36TR, TWILIGHT -II-B CAUTION: Logs are fragile! Carefully remove the logs from the packaging.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 67 STEP 4. LOG #3 (SRV2005-702): Position log #3 as shown by leaning it against log # 2 and resting the other end on the peak of the burner . DO NOT cover any port holes. STEP 5.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 68 STEP 7. LOG #6 (SR V2005-705): Locate the notch on log #6 and place it against the front right grate tine. Set the other end of the log so it rests on the fl at area of log #1.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 69 I. Air Shutter Setting This appliance has an adjustable air shutter (which con- trols the primary air) factory set for the minimum vertical vent run.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 70 1 5 15 T roubleshooting With proper installation, operation, and maintenance your gas appliance will provide years of trouble-free service.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 71 IntelliFire Ignition System - (continued) Symptom Possible Cause Corrective Action 4.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 72 1 6 16 Reference Materials A. Appliance Dimension Diagram Dimensions are actual appliance dimensions. Use for reference only. For framing dimensions and clearances refer to Section 5.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 73 Figure 16.2 Pier Dimensions B C FRONT VIEW RIGHT VIEW LEFT VIEW A P L Ø K D M O N E ELECTRICAL ACCESS GAS LINE ACCESS .
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 74 B. V ent Components Diagrams Figure 16.3 DVP vent components 10-1/2 in. (267 mm) 10-7/8 in. (276 mm) 45 ° 7-3/8 in. (187 mm) 11-3/8 in. (289 mm) 1-1/4 in. (32 mm) 9-1/4 in.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 75 DVP-HPC1 DVP-HPC2 DVP-TRAP1 DVP-TRAP2 DVP-TRAPK2 DVP-TRAPK1 DVP-TRAP Horizontal T ermination Cap 15-1/8 in. (384 mm) 12 in. (305 mm) 8 in. (203 mm) Max Effective Length Note: Heat shields MUST overlap by a minimum of 1-1/2 in.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 76 13-1/4 in. (367 mm) 24-5/8 in. (625 mm) 27-1/2 in. (127 mm) RF6M Roof Flashing Multi-pak 31 in. (787 mm) 24-5/8 in. (625 mm) 13-1/4 in. (367 mm) RF12M Roof Flashing Multi-pak BEK Trap Ca p Brick Extension 13-3/4 in.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 77 DVP-TB1 BasementVent Cap 12 in. (305 mm) 1-1/2 in. (38 mm) 7-3/8 in. (187 mm) 14 in. (356 mm) 17-3/4 in. (451 mm) 10-1/2 in. (267 mm) 3-7/8 in. (98 mm) DVP-TV VerticalTermination Cap 7-1/4 in.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 78 B. V ent Components Diagrams (continued) Figure 16.7 V ent Components 13 in. (330 mm) 15 in. (381 mm) 8-1/8 in. (206 mm) DVP-HRC-SS Optional Wire Harness DESCRIPTION P ART NUMBER 10 ft.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 79 B. V ent Components Diagrams (continued) Figure 16.8 SLP Series V ent Components EFFECTIVE HEIGHT/ LENGTH 8-3/4 in. 222 mm 6-1/2 in. 165 mm 6-5/8 in. 168 mm 6 in. 152 mm 6-1/2 in.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 80 SLK-SNKD Snorkel T ermination Cap SLP-TVHW V ertical T ermination Cap SLP-FLEX-TRAP Horizontal T ermination Kit SLP-CCS-BK Cathedral Ceiling Support Box-Black SLP-DCF-BK Ceiling Firestop Black SLP-WT -BK W all Thimble-Black B.
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 81 C. Service Parts ST -36TR-IPI Beginning Manufacturing Date: Nov . 2008 Ending Manufacturing Date:______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 82 C. Service Parts PIER-36TR-IPI Beginning Manufacturing Date: Nov . 2008 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 83 PIER-36TR, ST -36TR-IPI C. Service Parts Beginning Manufacturing Date: Nov . 2008 Ending Manufacturing Date: ______ IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 84 C. Service Parts List ST -36TR-IPI, PIER-36TR-IPI IMPORT ANT : THIS IS DA TED INFORMA TION. When requesting service or replacement parts for your appliance please provide model number and serial number .
Heat & Glo • ST -36TR-IPI, PIER-36TR-IPI • 2176-900 Rev . F • 8/1 1 85 Heat & Glo, a brand of Hearth & Home T echnologies Inc. 7571 215 th Street West, Lakeville, MN 55044 www .heatnglo.com D. Contact Information Please contact your Heat & Glo dealer with any questions or concerns.
Een belangrijk punt na aankoop van elk apparaat Heat & Glo LifeStyle PIER-36TR-IPI (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Heat & Glo LifeStyle PIER-36TR-IPI heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Heat & Glo LifeStyle PIER-36TR-IPI vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Heat & Glo LifeStyle PIER-36TR-IPI leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Heat & Glo LifeStyle PIER-36TR-IPI krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Heat & Glo LifeStyle PIER-36TR-IPI bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Heat & Glo LifeStyle PIER-36TR-IPI kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Heat & Glo LifeStyle PIER-36TR-IPI . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.