This parts list is current as of the above revision date.



MODEL NUMBER EXPLANATION G L D H - 6 0 E 3 B 1 2 3 4 5 6 7 (1) GAS (2) 90% EFFICIENCY (3) DOWNFLOW/HORIZONTAL CONDENSING (4) PLACEHOLDER (5) HEATING INPUT DESIGNATION 40 = 45,000 BTU/HR 60 - 60,000 BTU/HR E = Electric 75 = 75,000 BTU/HR N = NOX 90 = 90,000 BTU/HR 105 = 105,000 BTU/HR 120 = 120,000 BTU/HR (6) DRIVE NOMINAL COOLING/REVISION LEVEL 3 = 3 Ton 4 = 4 Ton 5 = 5 Ton (7) REVISION LEVEL
SERIAL NUMBER EXPLANATION G Y 5 D 7 0 2 F 3 1 0 7 9 1 2 3 4 5 6 7 8 9 10 1 GAS CODE 6 MOTOR HORSEPOWER 2 LIMIT CONTROL 7 PLANT 3 BLOWER 8 WEEK 4 HEATING ELEMENT 9 YEAR 5 SPECIAL AREA REQUIREMENT 10 PRODUCTION NUMBER















EL GAS CONTROLS 51 Stk Integrated Furnace Control Board (IFC) 62-25338-01 62-24140-04 62-24140-04 61 Stk Gas Valve - Natural Gas 60-100394-02 60-22866-01 60-23490-01 61 Stk,1 Gas Valve - LP See Note 1 See Note 1 See Note 1 63 Stk Ignitor 62-24141-04 62-24141-04 62-24141-04 64 Ignitor Bracket AE-61885-02 AE-61885-02 AE-61885-02 65 Stk Flame Sensor 62-23543-01 62-23543-01 62-23543-01 Stk LP Conversion Kit FP-02 FP-02 FP-02


90% GAS FURNACE - ORIFICE SELECTION CHART - NATURAL GAS CAUTION: Selection of the correct Natural Gas Orifice requires the following information for the specific installation: 1) Altitude in of the installation (ft.). 2) Average energy content of the Natural Gas fuel from the local supplier (BTU/cu. ft.). For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the National Fuel Gas Code Handbook, or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1. CAUTION: This information is provided for replacement purposes only. Conversion for operation at High Altitude must be done using the kit specified on the product specification sheet for the unit. NOTE: This Orifice sizing chart is based on 15,000 BTU/HR per burner. NOTE: Factory installed orifices are calculated and sized based on a Natural Gas heating value of 1075 BTU/cu. ft. and an elevation of 0 - 2000 ft. Elevation (ft.) Energy Value
(BTU/cu. ft.)
850 62-22175-47 62-22175-48 62-22175-48 62-22175-49 62-22175-49 62-22175-49 62-22175-50 62-22175-50 900 62-22175-48 62-22175-49 62-22175-49 62-22175-49 62-22175-50 62-22175-50 62-22175-50 62-22175-51 975 62-22175-49 62-22175-50 62-22175-50 62-22175-50 62-22175-51 62-22175-51 62-22175-51 62-22175-52 1075 62-22175-50 62-22175-51 62-22175-52 62-22175-52 62-22175-52 1170 62-22175-51 62-22175-51 62-22175-52 62-22175-52 62-22175-52 62-22175-53 62-22175-53 62-22175-53 90% GAS FURNACE - ORIFICE SELECTION CHART - LP CAUTION: Selection of the correct LP Orifice requires the altitude of the specific installation (ft.). For detailed information and instructions for Orifice selection, see the Gas Furnace LP Conversion Kit Index 92-21519-59 and the latest edition of the National Fuel Gas Code Handbook (NFG), or the National Standard of Canada, Natural Gas and Propane Installation Code, CAN B149.1. CAUTION: This information is provided for replacement purposes only. Conversion to LP or for operation at High Altitude should be done using the kit(s) specified on the product specification sheet for the unit. NOTE: This Orifice sizing chart is based on 15,000 BTU/HR per burner. Also, the chart is developed using the specified pressure setting of 10 in. water column instead of the 11.0 in water column used by the NFG and CANB149.1. NOTE: Orifices supplied in the LP Conversion Kit are calculated and sized based on an altitude of 0 - 2000 ft.
Elevation (ft.) Orifice 0 to 2000 ft. 62-22175-91 2001 to 3000 62-22175-91 3001 to 4000 62-22175-90 4001 to 5000 62-22175-58 5001 to 6000 62-22175-59 6001 to 7000 62-22175-60 7001 to 8000 62-22175-62 8001 to 9000 62-22175-63 9001 to 1000 62-22175-64










Stk It is recommended that stock be maintained for this part. N/A Not Applicable
1 Order Gas Valve for Natural Gas along with LP Conversion Kit 2 Units manufactured before F5109 used a limit switch with a set point different that the specified replacement. The specified replacement should be used for all units regardless of date code. 3 Parts Bag deletion of 68-24026-04 Drain Tube requires that Tube 79-102882-01 be cut to length for horizontal applications on units produced after approximate date code F2209.
1900 Wellworth Jackson, MI 49203