CSL CSM CSB 62 INTRODUCTION This section provides the installation instr uctions for the Henny Penny Electric Combi-Steamers. NOTE: The installation of this unit must conform to all local, state, and federal codes. In the absence of codes use ANSI/NFP A No.
CSL CSM CSB 63 Installation – Electric Units (continued) Floor Units: NOTE: Adequate clearance must be provided for ser vicing and for operation. Minimum clearances have to be maintained from the adjacent walls.
CSL CSM CSB 64 ELECTRICAL SUPPL Y Standard electrical supply for all Combi-Steamers is 208-240 volt, 3 phase, 50-60 Hz. NOTE: The power connections are located behind the ser vice door (see section 5-3).
CSL CSM CSB 65 WA TER SUPPLY The Combi-Steamer should only be connected to a cold water supply which meets the quality requir ements by the EPA on drinking water . Soft water must be at least 5 or 6 grains. The recommended water supply pr essure is 44 psi, but 22 to 87 psi will work.
CSG 66 INSTALLA TION GAS UNITS This section provides the installation instr uctions for the Henny Penny Gas Combi-Steamers NOTE: The installation must conform with local codes or in the absence of local codes, with ANSI Z223.1 latest edition and electrical code ANSI/NFP A No.
CSG 67 Minor unevenness of the sur face/floor can be compensated by adjusting the metal legs of the stand or the appliance. The weight of the units are as follows: CSG-10 556 lbs.
CSG 68 WA TER SUPPLY-CSG The Combi-Steamer should only be connected to a cold water supply which meets the quality requir ements by the EP A on drinking water . Soft water must be at least 5 or 6 grains. The recommended water supply pr essure is 44 psi, but 22 to 87 psi will work.
CSG 69 Installation – Gas Units (continued) ELECTRICAL SUPPL Y -CSG The gas Combi-Steamer requir es 120 volt, single phase, 60 Her tz, 15 amp, 3 wire grounded ser vice.
CSG 70 GAS SUPPL Y -CSG RIGHT MINIMUM PULL of equipment away from wall permissible for accessibility to Quick Disconnect Device WRONG A VOID SHARP BENDS AND KINKS when pulling equipment away from wall. (Maximum pull will kink ends, even if installed properly , and reduce Connector life.
CSG 71 GAS SUPPL Y (continued) A steam bur ner gas valve and dr y heat bur ner gas valve r espectively are responsible for the gas supply to the indi- vidual bur ners. The Combi-Steamer models CSG have manual shut-of f valves, that can be r eached from the front without tools.
CSG 72 NOTE: After turning on the gas, the manual shut-of f valve must remain open, except during pressure testing as outlined in the above steps, or when necessar y during service maintenance. This incoming pressur e reading can be taken by installing a gas pressur e gauge on the front of the unit’s main gas valves test por t.
Een belangrijk punt na aankoop van elk apparaat Henny Penny CSM (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Henny Penny CSM heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Henny Penny CSM vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Henny Penny CSM leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Henny Penny CSM krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Henny Penny CSM bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Henny Penny CSM kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Henny Penny CSM . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.