– 1 – ENGLISH SPLIT TYPE AIR CONDITIONER INDOOR UNIT/OUTDOOR UNIT MODEL RAS-08KH2/RA C-08KH2 RAS-10KH2/RA C-10KH2 RAS-14KH2/RA C-14KH2 OUTDOOR UNIT INDOOR UNIT RAC-14KH2 RAS-08KH2 RAS-10KH2 RAS-14KH2 Instruction manual To obtain the best performance and ensure years of trouble free use, please read this instruction manual completely.
– 2 – ! SAFETY PRECAUTION ● Please read the “ Safety Precaution ” carefully before operating the unit to ensure correct usage of the unit. ● Pay special attention to signs of “ Warning ” and “ Caution ” . The “ Warning ” section contains matters which, if not observed strictly, may cause death or serious injury.
– 3 – ENGLISH PRECA UTIONS DURING OPERA TION ● Do not attempt to operate the unit with wet hands, this could cause fatal accident. ● When operating the unit with burning equipments, regularly ventilate the room to avoid oxygen insufficiency.
– 4 – INDOOR UNIT NAMES AND FUNCTIONS OF EACH P AR T Air filter To prevent dust from coming into the indoor unit. (Refer page 21) Front panel Indoor unit indicators Light indicator showing the operating condition.
– 5 – ENGLISH INDOOR UNIT INDICA TORS TEMPORARY SWITCH Use this switch to start and stop when the remote controller does not work. [Use non-conductor stick (example toothpick)] ● By pressing the temporary switch, the operation is done in previously set operation mode.
– 6 – AUTO HEAT DEHUMIDIFY COOL FAN FAN SPEED LOW MED HI SLEEPING STOP (CANCEL) START (RESERVE) START/STOP TIME TIMER SET TIMER SELECTOR ON TIMER OFF TIMER AUTO SWING ˚ CH RESET ˚ CH NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT REMOTE CONTROLLER ● This controls the operation of the indoor unit.
– 7 – ENGLISH AUTOMA TIC OPERA TION The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on the initial room temperature. The selected mode of operation will not change when the room temperature varies.
– 8 – HEA TING OPERA TION ● Use the device for heating when the outdoor temperature is under 21 ° C. When it is too warm (over 24 ° C), the heating function may not work in order to protect the device. ● In order to keep reliability of the device, please use this device above – 10 ° C of the outdoor temperature.
– 9 – ENGLISH RESET ˚ C ˚ C DEHUMIDIFYING OPERA TION Use the device for dehumidifying when the room temperature is over 16 ° C. When it is under 15 ° C, the dehumidifying function will not work.
– 10 – ˚ C RESET ˚ C COOLING OPERA TION Use the device for cooling when the outdoor temperature is 22-42 ° C. If indoor humidity is very high (over 80%), some dew may form on the air outlet grille of the indoor unit. Press the FUNCTION selector so that the display indicates (COOL).
– 11 – ENGLISH FAN SPEED (AUTO) ..... When the AUTO fan speed mode is set in the cooling/heating operation: For the heating operation ● The fan speed will automatically change according to the temperature of discharged air. ● When the difference of room temperature and setting temperature is large, fan starts to run at HI speed.
– 12 – HOW TO SET THE TIMER ON/OFF-Timer ● The device will turn on (off) and off (on) at the designated times. ● The switching occurs first at the preset time that comes earlier. ● The arrow mark appearing on the display indicates the sequence of switching operations.
– 13 – ENGLISH 3 Point the signal window of the remote controller toward the indoor unit, and press the (RESERVE) button. The (OFF) mark starts lighting instead of flashing and the sign (RESERVED) lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.
– 14 – HOW TO SET THE SLEEP TIMER 1 Set the ON-timer. Set the current time at first if it is not set bef ore (see the pages f or setting the current time).
– 15 – ENGLISH Cooling “ ” and dehumidifying “ ” Explanation of the sleep timer The de vice will control the F AN SPEED and room temperature automatically so as to be quiet and good f or people ’ s health. Y ou can set the sleep timer to tur n off after 1, 2, 3 or 7 hours .
– 16 – ADJUSTING THE AIR DEFLECTOR 1 2 Adjustment of the conditioned air to the left and right. Hold the vertical air deflector as shown in the figure and adjust the conditioned air to the left and right. ● If the “ (AUTO SWING)” button is pressed once, the horizontal air deflector swings up and down.
– 17 – ENGLISH HOW TO EXCHANGE THE BA TTERIES IN THE REMOTE CONTROLLER 1 Remove the cover as shown in the figure and take out the old batteries. = 2 Install the new batteries. The direction of the batteries should match the marks in the case. 1. Do not use new and old batteries, or different kinds of batteries together.
– 18 – Suitable Room T emperature Install curtain or blinds V entilation Effective Usa ge Of Timer Do Not For get T o Clean The Air Filter Please Adjust Suitable T emperature For Bab y And Children Warning Freezing temperature is bad for health and a waste of electric power.
– 19 – ENGLISH FOR USER’S INFORMA TION The Air Conditioner And The Heat Source In The Room Not Operating For A Long Time When Lightning Occurs Caution If the amount of heat in the room is above the cooling capability of the air conditioner (for example: more people entering the room, using heating equipments and etc.
– 20 – A TT ACHING THE AIR CLEANSING AND DEODORIZING FIL TERS Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning, stop operation and switch off the power supply. CAUTION ! NOTE ● In case of removing the air cleansing and deodorizing filters, please follow the above procedures.
– 21 – ENGLISH MAINTENANCE Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning, stop operation and switch off the power supply.
– 22 – 3. MAINTENANCE AT BEGINNING OF LONG OFF PERIOD ● Run the unit by setting the operation mode to (FAN) and the fan speed to HI for about half a day on a fine day, and dry the whole of the unit. ● Switch off the power plug. Air Blow 2. Washable Front Panel ● Remove the front panel and wash with clean water.
– 23 – ENGLISH Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning, stop operation and switch off the power supply. ! CAUTION Confirm CAUTION ● Please use earth line. Do not place the earth line near water or gas pipes, lightning-conductor, or the earth line of telephone.
– 24 – AFTER SALE SERVICE AND W ARRANTY WHEN ASKING FOR SERVICE, CHECK THE FOLLOWING POINTS. When it does not operate ● Is the fuse all right? ● Is the voltage extremely high or low? ● Is th.
– 25 – ENGLISH MEMO ..................................................................................................................................................................................... .............................................
– 26 – MEMO ..................................................................................................................................................................................... .....................................................
Een belangrijk punt na aankoop van elk apparaat Hitachi RAC-08KH2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hitachi RAC-08KH2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hitachi RAC-08KH2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hitachi RAC-08KH2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hitachi RAC-08KH2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hitachi RAC-08KH2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hitachi RAC-08KH2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hitachi RAC-08KH2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.