Gebruiksaanwijzing /service van het product IB235 ML-110861 van de fabrikant Hobart
Ga naar pagina of 20
– 1 – N S T R U C T I O N S I INFRARED BOOSTER . . . Gas W ater H eaters MODEL IB57 ML-110898 IB140 ML-110899 IB235 ML-110861 IB290 ML-110862 INFRARED BOOSTER 701 S. RIDGE AVENUE TROY, OHIO 45374-0001 937 332-3000 www.hobartcorp.com FORM 34070 Rev.
– 2 – IMPORT ANT FOR YOUR SAFETY WARNING: IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR DEATH. DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
– 3 – TABLE OF CONTENTS IMPORTANT FOR YOUR SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
– 4 – Installation, Operation, and Care of INFRARED BOOSTER GAS WA TER HEA TERS SA VE THESE INSTRUCTIONS GENERAL The Infrared Booster Gas Water Heaters (available for natural gas or propane) provide 180 ° F rinse water for commercial dishwashing machines.
– 5 – INST ALLA TION UNPACKING Immediately after unpacking, check for possible shipping damage. If the Booster Heater is found to be damaged after unpacking, save the packaging material and contact the carrier within 15 days of delivery.
– 6 – VENTING REQUIREMENTS WARNING : PROVIDE A SCREEN OR BARRIER TO PREVENT PERSONAL INJURY IN AREAS WHERE INADVERTENT PERSONNEL CONTACT WITH THE HOT VENT PIPE CAN OCCUR. Models IB57 and IB140 are Category IV (positive flue pressure, excessive condensate, and flue gas temperature at the heater outlet approximately 330 ° F).
– 7 – Fig. 2 Fig. 3 Dish T able or Conveyor Dishwasher Combustible Sidewall T ermination T ermination T ee 6" T ermination T ee Non-Combustible Sidewall T ermination 6" T ermination T ee.
– 8 – Fig. 4 All horizontal runs of the vent pipe shall have a minimum rise of 1 / 4 " per foot of length and should be supported every 5 feet or less (for Canada, every 3 feet) and at every elbow.
– 9 – GAS CONNECTION For model IB57, the gas inlet pipe size is 1 / 2 " NPT at the gas valve. For models IB140, IB235, and IB290, the gas inlet pipe size is 3 / 4 " NPT at the gas valve. The gas supply line must be sized to adequately provide the input BTU/Hr rate for that model at the specified flowing pressure (see table).
– 10 – WATER REQUIREMENTS Proper water quality can improve ware washing performance by reducing spotting, lowering chemical supply costs, enhancing effectiveness of labor, and extending equipment life. Local water conditions vary from one location to another.
– 11 – SHOWN WITH OPTIONAL WATER HAMMER ARRESTOR KIT Fig. 6 The heater is equipped with a pump which circulates water inside the booster heater and maintains a uniform water temperature in the tank.
– 12 – ELECTRICAL CONNECTIONS WARNING : ELECTRICAL AND GROUNDING CONNECTIONS MUST COMPLY WITH APPLICABLE PORTIONS OF THE NATIONAL ELECTRICAL CODE AND/OR OTHER ELECTRICAL CODES. WARNING : DISCONNECT THE ELECTRICAL POWER SUPPLY AND PLACE A TAG AT THE DISCONNECT SWITCH INDICATING THAT THE CIRCUIT IS BEING WORKED ON.
– 13 –.
– 14 – START UP PROCEDURES — FOR YOUR SAFETY READ BEFORE OPERATING Filling the Booster Piping Fill the booster heater with water, purging all air.
– 15 – Hot Surface Ignition Using the Robertshaw Gas Valve 1. STOP! Read the safety information. 2. Turn off all electrical power to the appliance. 3. Remove the left side panel. 4. This appliance is equipped with an ignition device which automatically lights the burners.
– 16 – OPERA TION The booster heater is designed to deliver 180 ° F water, up to the gallons per minute and gallons per hour ratings specified in the table on page 4, depending on the incoming water temperature and Booster Heater model and its input BTU/Hr.
– 17 – MAINTENANCE LUBRICATION The water pump motor and the combustion air blower motor are permanently lubricated and require no other maintenance. VENT SYSTEM Annually check the vent system for obstruction. Check for signs of deformation in the vent pipes which will be an indication of abnormal conditions in the venting system.
– 18 – LIST OF REPLACEMENT PARTS When ordering parts, be sure to provide the Model Number, ML Number, and Serial Number from the data plate located on the left-front panel of the booster heater. NOTE : As continued product improvement is a policy of the manufacturer, part numbers may change without notification.
– 19 – Components (Pump Side) continued PART No. NAME OF PART AMT FP 047-12 FITTING-TUBE 5 / 8 TBG FERRULE (140,000 & 235,000 BTU/Hr) . . . . . . . . . . . . . . . . . . . 1 FP 012-45 FITTING-TUBE 5 / 8 TBG NUT (140,000 & 235,000 BTU/Hr) .
– 20 – Components (Pump Side) continued PART No. NAME OF PART AMT 00 294500 040-1 TRANSFORMER, 30VA, 50/60HZ . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 00 294681 028-1 THERMOSTAT, AUTO RESET . . . . . . . .
Een belangrijk punt na aankoop van elk apparaat Hobart IB235 ML-110861 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hobart IB235 ML-110861 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hobart IB235 ML-110861 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hobart IB235 ML-110861 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hobart IB235 ML-110861 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hobart IB235 ML-110861 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hobart IB235 ML-110861 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hobart IB235 ML-110861 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.