Visit our website at www.HobartWelders.com Processes Description MIG (GMA W) W elding Flux Cored (FCA W) W elding Wire Feeder OM-193 471G July 2000 Olympic R-1 15.
Hobart W elders manufactures a full line of welders and welding related equipment. For information on other quality Hobart products, contact your local Hobart distributor to receive the latest full line catalog or individual catalog sheets. T o locate your nearest distributor or service agency call 1-877-Hobart1.
W ARNING T ABLE OF CONTENTS SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1. Symbol Usage 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
.
OM-193 471 Page 1 SECTION 1 – SAFETY PRECAUTIONS - READ BEFORE USING som _nd_4/98 1-1. Symbol Usage Means W arning! W atch Out! There are possible hazards with this procedure! The possible hazards are shown in the adjoining symbols. Y Marks a special safety message.
OM-193 471 Page 2 Arc rays from the welding process produce intense visible and invisible (ultraviolet and infrared) rays that can burn eyes and skin. Sparks fly off from the weld. ARC RA YS can burn eyes and skin. D Wear a welding helmet fitted with a proper shade of filter to protect your face and eyes when welding or watching (see ANSI Z49.
OM-193 471 Page 3 1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over , or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring – be sure power supply system is properly sized, rated, and protected to handle this unit.
OM-193 471 Page 4 1-5. EMF Information Considerations About W elding And The Effects Of Low Frequency Electric A n d M a g netic Fields W elding current, as it flows through welding cables, will cause electro- magnetic fields. There has been and still is some concern about such fields.
OM-193 471 Page 5 SECTION 1 – CONSIGNES DE SECURITE – LIRE A V ANT UTILISA TION som _nd_fre 4/98 1-1. Signification des symboles Signifie Mise en garde ! Soyez vigilant ! Cette proc é dure pr é sente des risques de danger ! Ceux-ci sont identifi é s par des symboles adjacents aux directives.
OM-193 471 Page 6 Le rayonnement de l ’ arc du proc é d é de soudage g é n è re des rayons visibles et invisibles intenses (ultraviolets et infrarouges) susceptibles de provoquer des br û lures dans les yeux et sur la peau. Des é tincelles sont projet é es pendant le soudage.
OM-193 471 Page 7 1-3. Dangers suppl é mentaires en relation avec l ’ installation, le fonctionnement et la maintenance Risque D ’ INCENDIE OU D ’ EXPLOSION. D Ne pas placer l ’ appareil sur , au-dessus ou à proxi- mit é de surfaces infllammables.
OM-193 471 Page 8 1-4. Principales normes de s é curit é Safety in W elding and Cutting, norme ANSI Z49.1, de l ’ American Wel- ding Society , 550 N.W . Lejeune Rd, Miami FL 33126 Safety and Health Sandards, OSHA 29 CFR 1910, du Superintendent of Documents, U.
OM-193 471 Page 9 SECTION 2 – INST ALLA TION 2-1. Specifications T ype of Input Power W elding Power Source T ype Wire Feed Speed Range Wire Diameter Range W elding Circuit Rating Overall Dimensions W eight 1 15 V olts AC Single Phase 2 Amperes 50/60 Hz Constant V oltage (CV) DC And Contactor Control 75 to 750 ipm (1.
OM-193 471 Page 10 2-3. Gun Recommendation T able Process Gun GMA W – Hard or Corded Wires M25 Or M40 FCA W – Self-Shielding Wires GA-40GL 1 CV Welding Power Source With 1 15 V AC Power 2 Interconnecting Control Cord (Required) 3 Weld Cable (Required) 4 W ork 2-4.
OM-193 471 Page 1 1 1 Gun Securing Knob 2 Gun Block 3 Gun Outlet Wire Guide Loosen knob, insert gun into block. Position outlet wire guide as close as possible to drive rolls without touching. T ighten knob. 4 Gun Trigger Receptacle 5 Gun Trigger Plug 6 Weld Cable T erminal 7 Weld Cable From W elding Power Source 2-6.
OM-193 471 Page 12 2-7. Installing Wire Guide And Drive Roll 802 310-A 1 Inlet Wire Guide 2 Intermediate Wire Guide Install and secure inlet wire guide, and intermediate wire guide. 3 Drive Roll (4) Install drive rolls and turn drive roll nut one click.
OM-193 471 Page 13 2-8. Installing And Threading Welding Wire T ools Nee d e d : 1 Retaining Ring 2 Hub T ension Adjustment Nut If nec essary, move hub on support for use of different size wire spool. Remove retaining ring, and install spool so hub pin fits spool hole.
OM-193 471 Page 14 2-9. Interconnecting Power Cord Ground Lead Connection (All Models) Ref. 802 310 . The interconnecting power cord is not supplied with the unit. Be sure to obtain the prop- er interconnecting power cord for the welding power source the wire feeder is being con- nected to.
OM-193 471 Page 15 2-1 1. Connection For Hobart W elding Power Sources With 19-Socket Receptacle Ref. 802 310 / Ref. 193 749 1 T erminal Block 1T 2 Interconnecting Power Cord 3 Green Lead (Connected T.
OM-193 471 Page 16 2-13. Connection For Hobart W elding Power Sources With 5-Socket And 1 15 V olt AC Receptacles Ref. 802 310 / Ref. 193 749 1 T erminal Block 1T 2 3-Conductor Cord 3 2-Conductor Cord.
OM-193 471 Page 17 2-15. Connection For Lincoln Welding Power Sources With T erminal Strip Connections Ref. 802 310 / Ref. 193 749 1 T erminal Block 1T 2 Interconnecting Power Cord 3 Green Lead (Conne.
OM-193 471 Page 18 2-17. Connection For Welding Power Sources With Hubbell Receptacles Ref. 802 310 / Ref. 193 749 1 T erminal Block 1T 2 Interconnecting Power Cord 3 Green Lead (Connected T o Ground .
OM-193 471 Page 19 2-19. Motor Start/Burnback Control Ref. 802 310 / 192 653 T o change wire feed starting speed proceed as follows: T urn Off unit and welding power source. Remove wrapper . 1 Motor Board PC1 2 Motor Start Control Potentiometer R73 Remove protective white rubber cap before making adjustment.
OM-193 471 Page 20 SECTION 3 – OPERA TION 3-1. Front Panel Controls 1 Wire Speed Control 2 Jog/Purge Switch Use Jog position to momentarily feed welding wire at speed set on Wire Speed control without energizing welding circuit or shielding gas valve.
OM-193 471 Page 21 SECTION 4 – MAINTENANCE & TROUBLESHOOTING 4-1. Routine Maintenance Y Disconnect power before maintaining. 3 Months Replace Unreadable Labels Clean And T ighten W eld T erminal.
OM-193 471 Page 22 4-3. T roubleshooting T rouble Remedy Wire does not feed, unit completely inop- erative. T urn Power switch On. Check circuit breaker CB1 (see Section 4-2). Check Interconnecting control cord connections (see Section 2-9). Check input power .
OM-193 471 Page 23 SECTION 5 – ELECTRICAL DIAGRAM 193 378-C ROUTE WELD CABLE THROUGH REED SWITCH ASSEMBL Y NOTE: Figure 5-1. Circuit Diagram For Wire Feeder With Optional Equipment.
OM-193 471 Page 24 SECTION 6 – P ARTS LIST . Hardware is common and not available unless listed. 1 2 3 5 6 7 11 10 4 8 9 10 9 12 13 14 15 16 17 18 19 20 21 22 23 24 25 27 28 29 30 31 32 33 34 35 26 36 37 38 802 305-B Figure 6-1. Main Assembly Description Part No.
OM-193 471 Page 25 Description Part No. Dia. Mkgs. Item No. Figure 6-1. Main Assembly (Continued) Quantity 18 044 426 CONNECTOR, clamp cable 1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-193 471 Page 26 Description Part No. Dia. Mkgs. Item No. Figure 6-2. Drive Assembly , Wire (Fig 7-2 Item 1) Quantity 1 602 009 SCREW , .250-20 x 1.250 soc hd hex gr 8 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
OM-193 471 Page 27 T able 6-1. Drive Roll & Wire Guide Kits Base selection of drive rolls upon the following recommended usages: 1. V -Grooved rolls for hard wire. 2. U-Grooved rolls for soft and soft shelled cored wires. 3. U-Cogged rolls for extremely soft shelled wires (usually hard surfacing types).
OM-193 471 Page 28 Notes.
OM-193 471 Page 29 Notes.
OM-193 471 Page 30 Notes.
Warranty Questions? Call 1-877-HOBART1 for your local Hobart distributor. hobart standard 7/00 Service Y o u always get the fast, reliable response you need. Most replacement parts can be in your hands in 24 hours. Support Need fast answers to the tough welding questions? Contact your distributor or call 1-800-332-3281.
PRINTED IN USA 2000 Hobart Welding Products. 1/00 Hoba rt W elding Produc ts An I l li noi s T ool Works Com pany 600 West Main St reet Troy , O H 45373 US A For Technical A ssistan ce: Call1-800-.
Een belangrijk punt na aankoop van elk apparaat Hobart Welding Products R-115 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hobart Welding Products R-115 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hobart Welding Products R-115 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hobart Welding Products R-115 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hobart Welding Products R-115 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hobart Welding Products R-115 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hobart Welding Products R-115 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hobart Welding Products R-115 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.