Gebruiksaanwijzing /service van het product RC-1000 van de fabrikant Home Automation
Ga naar pagina of 16
1 1 RC-1000 Th ermostat Installation Ins tructions DESCRIPTION The RC-1000 is a precision digital thermostat designed for 24 VAC he ating and cooling systems.
2 2 Location When replacing an ex isting thermostat, install the RC-1000 in the same location. If the existing location doesn' t meet the following criteria, choose a n ew location to mount the RC-1000. When choosing a location for the thermostat: 1.
3 3 Connect each wire to the terminal st rip(s) on the thermostat base per the wiring diagram for your system application - See Figures 4 - 7. Form the thermostat wiring so that the ca ble lies flat between the termina l strip(s) and the center of the base - See Figure 2 .
4 4 TYPICAL WIRING DIAGRAMS CA UTION : Do not short gas valve, fan, heat relay, or cool rela y ...even momentaril y. Do not attempt to hook up to live circuits. An accidental connection to a component on the thermostat circuit board could cause damage to the thermostat.
5 5 3. When configured as a co nventional thermostat, by default this the rmostat does not turn the fan on with a call for heat. If the furnace requi res the thermostat to turn the fan on with a call for heat, confi gure the “System Mode” to “Fan On W ith Heat” under “System Options” .
6 6 Single Stage Conventional 24VAC " HOT" Heat 24VAC Com mon* Fan Cool UP 24V AC CONTROL TRANSM FOMER Fan Relay Cool Relay Heat Relay HVAC SYSTEM THERMOSTAT (RC) (C) (Y1) (G) (W1) 1 3 8 6 7 * Common wire is required in “heat only” or “cool only” applications .
7 7 About Heat Pump System s 1) Terminal 5 (O) is energized for coolin g Terminal 6 (B) is energized for heating In most applications, the reversing valve is energiz ed for cooling and should be connected to the "O" terminal.
8 8 Heat Pum p (2 Stage Heat / 1 Stage Cool) 24VAC Common 24VAC "HOT" Auxilirary Heat Compressor Ground Fault Fan Compressor Relay Aux Heat Relay Fan Relay Fault Relay Reversing Valve Energi.
9 9 REMOTE SYSTEM WIRING DIAGRAMS This thermostat has been prepro grammed with energ y saving pro gram schedules in accordance with the ENERGY STAR ® program. W hen used with a remote system, HAI recommends that the Program Mode be configured as “None” or “Occup ancy”.
1 1 0 0 REMOTE SETBACK SWITCH The thermostat can be connected to a remote switch to toggle the desired heat and cool temperature se ttings between preset setpoints.
1 1 1 1 REMOTE TEMPERATURE SENSOR A remote temperature se nsor can be installed to monitor the temperature from a re mote location or can be combined with the onboard temperature sensor for the average temperature of two locations. Run a twisted pair, shielded cable from the RC-10 00 to the remote temperature sensor location.
1 1 2 2 SETUP AND CONFI GURATION NOTE: For proper operation of the features of this thermostat, the Ti me and Date must be set. Even w hen connected to an HAI controller which sets the time and day, the Date must be manually set in the ther mostat under the “S ettings” menu.
1 1 3 3 System Type *Conventional Dual Fuel Heat Pump 1 Heat Pump *Auto Changeover No Fan With Heat Auto Changeover Fan On With Heat Auto Changeover Fan On With Heat Auto Changeover Fan On With Heat M.
1 1 4 4 Cool Mi ni mu m On The number of minutes the thermostat forces the cooling system to remain on before turning off. Raising this number will increase the total time the cooling s y stem is on (saving energ y ), but may allow the temperature to drif t farther from setpoint (decreasing comfort).
1 1 5 5 Auxiliary Heat Diffe rential: This determines how far from the setpoint the temperature has to be b efore the auxiliary heat turns on. This is onl y available for heat pump s y stems.
1 1 6 6 TROUBLESHOOTIN G TIPS SYMP TOM ACTION TO TAKE 1. Check power to the thermostat Thermostat Dead 2. Check wiring diagrams SYMP TOM ACTION TO TAKE 1. Check for break in W or Y wire 2. Allow minimum off time to pass 3. Check sy stem options for correct setting s 4.
Een belangrijk punt na aankoop van elk apparaat Home Automation RC-1000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Home Automation RC-1000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Home Automation RC-1000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Home Automation RC-1000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Home Automation RC-1000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Home Automation RC-1000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Home Automation RC-1000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Home Automation RC-1000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.