1 1 RC-2000 Th ermostat Installation Ins tructions DESCRIPTION The RC-2000 is a precision digital thermostat designed for 24 VAC he ating and cooling systems.
2 2 Location When replacing an ex isting thermostat, install the RC-2000 in the same location. If the existing location doesn' t meet the following criteria, choose a n ew location to mount the RC-2000. When choosing a location for the thermostat: 1.
3 3 Connect each wire to the terminal st rip(s) on the thermostat base per the wiring diagram for your system application - See Figures 4 - 10. Form the thermostat wiring so that the ca ble lies flat between the terminal strip(s) and the center of the base - See Figure 2 .
4 4 TYPICAL WIRING DIAGRAMS CA UTION : Do not short gas valve, fan, heat relay, or cool rela y ...even momentaril y. Do not attempt to hook up to live circuits. An accidental connection to a component on the thermostat circuit board could cause damage to the thermostat.
5 5 3. When configured as a co nventional thermostat, by default this the rmostat does not turn the fan on with a call for heat. If the furnace requi res the thermostat to turn the fan on with a call for heat, confi gure the “System Mode” to “Fan On W ith Heat” under “System Options” .
6 6 Single Stage Conventional 24VAC "HOT" Heat 24VAC Com mon* Fan Cool Humidifier Dehumidier UP 24VAC CONTROL TRANSMFOMER Dehumidifie r Humidifier Fan Relay Cool Rela y Heat Rela y HVAC SYSTEM THERMOSTAT (RC) (C) (Y1) (G) (W1) (D) (H) 1 3 8 6 7 11 12 * Common wire is required in “heat only” or “cool only” applications .
7 7 Single Stage Conventional for Zon e Control Systems (W2) 4 (Y2) (D) (H) (G) (Y1) (W1) (C) (RC) 10 1 3 8 6 7 11 12 ZONE CONTROLLER THERMOSTAT Dehum idifier Humidi fier System Cool Mode Fan Relay Zo.
8 8 Two Stage Conventional (2 Stage Heat / 2 Stage Cool) UP Heat 1 Heat 2 24VAC Common* 24VAC "HOT" Dehumi dier Humidifier Cool 2 Cool 1 Fan 24VAC CONTROL TRANSMFOMER Heat 2 Relay Heat 1 Rel.
9 9 About Heat Pump System s 1) Terminal 5 (O) is energized for coolin g Terminal 6 (B) is energized for heating In most applications, the reversing valve is energiz ed for cooling and should be connected to the "O" terminal.
1 1 0 0 Heat Pum p (2 Stage Heat / 1 Stage Cool) 24VAC Common* 24VAC "HOT" Auxilirary Heat Compressor Ground Fault Humidifier Fan Dehumidier Compre ssor Re lay Aux Heat Relay Fan Relay Humid.
1 1 1 1 Two Speed Heat Pump (3 Stage Heat / 2 Stage Cool) Comp Stage 2 Relay Comp Stag e 1 Rela y Comp ressor Stag e 2 9 5 4 1 3 8 6 7 11 12 (D) (H) (L) (G) (Y1) (B) (O) (W2) (C) (RC) UP HVAC S YSTEM .
1 1 2 2 REMOTE SYSTEM WIRING DIAGRAMS This thermostat has been prepro grammed with energy saving program schedules in accord ance with the ENERGY STAR ® program. W hen used with a remote system, HAI recommends that the Program Mode be configured as “None” or “Occup ancy”.
1 1 3 3 REMOTE SETBACK SWITCH The thermostat can be connected to a remote switch to toggle the desired heat and cool temperature se ttings between preset setpoints.
1 1 4 4 REMOTE TEMPERATURE SENSOR A remote temperature se nsor can be installed to monitor the temperature from a re mote location or can be combined with the onboard temperature sensor for the average temperature of two locations. Run a twisted pair, shielded cable from the RC-20 00 to the remote temperature sensor location.
1 1 5 5 SETUP AND CONFI GURATION NOTE: For proper operation of the features of this thermostat, the Ti me and Date must be set. Even w hen connected to an HAI controller which sets the time and day, the Date must be manually set in the ther mostat under the “S ettings” menu.
1 1 6 6 System Options Note: Before op erating the the rmostat, the “S y stem Type” and “S ystem Mode” must be configured. The thermostat can be configured with the followi ng system options: .
1 1 7 7 Cool/Heat Min On/O ff These items are used to limit the on and off times of the cooling a nd heating system (in minutes). Cool Minimum On The number of minutes the thermostat forces the cooling system to remain on before turning off.
1 1 8 8 This thermostat is equipped with Energy Efficient Control (EEC) tha t continually monitors the performance of the HVAC system and uses Stage 2 (he at or cool) and Stage 3 (auxiliar y heat) onl y when necessary. If it determines that Sta ge 1 is able to heat or cool at a rate of 5 degrees per hour or better, Stage 2 will not be used.
1 1 9 9 Humidity Opt ions The Humidity Options are used to configure the d ehumidifier and/or humidifier output on the thermostat. Not Used: Dehumidifier/Humidifier output is disabled. Fan Speed Control: This option uses the dehumidifier output to control the fan speed on an HVAC system with a variable speed fan.
2 2 0 0 TROUBLESHOOTIN G TIPS SYMP TOM ACTION TO TAKE 1. Check power to the thermostat Thermostat Dead 2. Check wiring diagrams SYMP TOM ACTION TO TAKE 1. Check for break in W or Y wire 2. Allow minimum off time to pass 3. Check sy stem options for correct setting s 4.
Een belangrijk punt na aankoop van elk apparaat Home Automation RC-2000 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Home Automation RC-2000 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Home Automation RC-2000 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Home Automation RC-2000 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Home Automation RC-2000 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Home Automation RC-2000 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Home Automation RC-2000 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Home Automation RC-2000 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.