CONTENTS QUICK FIND Air Filter............ ... .............. .. ............... .... 11 Approved Liquids ................ ............... ...... 6 Contact Honda ............ ................. .......... 19 Find a Dealer ........... .............. ...
2 WELCOME Congratulations on your selection of a Honda multi-purpose pump! We are certain you will be pleased with your purchase of one of the finest pumps on the market. We want to help you get the best results from your new pump and to operate it safely .
3 P ARTS AND CONTROLS INITIAL PUMP SETUP Import ance of Proper Assembly Proper assembly is esse ntial to ope rator safety and the reliability of the machine. Any error or oversight made by the person assembli ng and servicing a machine can result in faulty operation, damage to the machine, or injury to the operator.
4 T ools Required 12 mm wrench T orque wre nch List of Loose Part s Carefully remove the p ump and loose parts from the carton and compare the loose part s against the following list. Contact the authorized Honda dealer from who m you pu rchased the pump if any of the loose parts shown are not incl uded with your pump.
5 Check Y our Pump For your safety, to ensure compliance with environmen tal regulations, and to maximize the service life of yo ur multi-purpose pum p, it is very important to take a few moments before you operate the pump to check its condition.
6 Approved Liquids The following tables list chemicals the multi-pu rpose pump is capable of pumping. Verify that the liquid to be pumped is listed in one of these tables. After each use, drain the pump chamber in to a suitable container and flush with fresh water.
7 2. Insert and remove the dipsti ck wit hout screwing it into the fill er neck. Check the oil level shown on the dipstick. 3. If the oil level is low , fi ll to the edge of the oil filler hole with the recommended oil. 4. Screw in the filler cap/dipstick securely.
8 If you need to leave the pump for any reason, alwa ys turn the engine OFF. Operator Responsibility It is the operator's resp onsibility to provide the necessa ry safeguards to protect people and property ag ains t chemical leakage. Refer to the handling instructions provided by th e ma nufacturer of the chemical before operating the pump.
9 S topping the Engine Emergency To stop the engine in an emergency, turn the ignition switch to the OFF position. Normal 1. Move the throttle lever fully to the right to the IDLE position. 2. Turn the ignition switch to the OFF position. 3. T urn the fuel valve to the OFF position.
10 Maintenance Schedule 1. For professional commercial use, log hours of operation to determine proper mainte nance intervals. 2. Service more frequently wh en used in dusty areas. 3. These items should be serviced by an authori zed Honda servicing dealer , unless you have the proper tools and are mechanically proficient.
11 Air Filter Check the air filter after each use. Clean the filter eve ry 50 hours of use. Clean the filter more often when used in dusty areas. Replace the filter ever y 300 hours of use. A properly maintained air filter will hel p prevent dirt from entering your engine.
12 1. Disconnect the spark plug cap and remove any dirt from around the spark plug area. 2. Use a spark plug wrench to remove the spark plug. 3. Visually insp ect the spark plug. Discard it if the insulator is cracked, chipped, or fouled. 4. Measu re the plug gap with a suitable gauge.
13 TRANSPORTING Before Loading If the engine has been running, allow it to cool for at le ast 15 minutes before loading the pump on the tran sport vehicl e. A hot engine and exhaust system can burn you and can ignite some materials. When transporting the pump, be sure to keep it upright.
14 4. If the pump was filled with a chemical, follow the chemical manufacturer’s handling procedures. Clean the pump interior by removing the pump drain plug and flushing with fresh wate r . After fl ushi ng , drain the water from the pump chamber .
15 Pump Will Not Pump TECHNICAL INFORMA TION Serial Number Locations There are two serial numb ers, one for the engine and one for the frame. Record the engine and frame serial nu mbers in the space below . Y ou will ne ed these serial numbers when ordering parts and when making technica l or warranty inquiries.
16 will not result in a failure of the engine to compl y with emissions regulations. Maintenance Follow the MAIN TENANCE SCHEDUL E on page 10 . Remember thi s schedule is based on the assumption that your mach ine will be used for its designed purpose.
17.
18 A VOIDING FUEL-RELA TED PROBLEMS When maintained properly , your Honda pump should provide years of trouble-free opera tion. This includes the fuel system. Howeve r , gasoline can quickly deteriorate, causing st arting or running problem s and , in some cases, damage to t he fuel system.
19 CUST OMER INFORMA TION Part s, Accessories, and Service Items Contact an authorized Honda servicing dealer to purchase any of these (or other) H onda Genuine Service parts and other approved accessories for your pump. For a co mplete list of pump accessories, visit us at powerequipment.
20 DISTRIBUT OR’S LIMITED W ARRANTY Honda Power Equipment This warranty is limited to the following Honda Power Equipment products when distributed by Ame rican Honda Motor Co., I n c., Power Equipment Division , 4900 Marconi Drive, Alpharetta, Ge orgia 30005-8847, purchased at retail or placed in rental service on or after January 1, 2010.
21 EMISSION SYSTEM W ARRANTY Y our new Honda Power Equipment engine complies with the U.S. EP A, Environment Canada, and S tate of Calif ornia emission regulations (models certified for sale in California only). American Honda Moto r Co., Inc. provides the emission warranty coverage for engines in the U nited S t ates and its territories.
22 NOTES.
PRODUCT REGISTRA TION Thank you for choosing Honda. T o ensure you receive import ant se rvice information in the event of a product update or recall , please register your pum p within 30 days of purchase. From time to time, American H onda conducts sales promotions that require you to register your pump within 30 days of purc hase.
HPE.2014.1 1 PRINTED IN U.S.A. EM5 1. Go to P ow erEquipment.Honda.com to regist er your unit. 2. Click on Pr oduct Registration . 3. C omplete the required inf ormation and click Submit . It ’ s that simple! Power Equipment Division American Honda Motor Co.
Een belangrijk punt na aankoop van elk apparaat Honda Power Equipment WMP20X (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Honda Power Equipment WMP20X heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Honda Power Equipment WMP20X vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Honda Power Equipment WMP20X leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Honda Power Equipment WMP20X krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Honda Power Equipment WMP20X bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Honda Power Equipment WMP20X kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Honda Power Equipment WMP20X . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.