Gebruiksaanwijzing /service van het product HR90 van de fabrikant Honeywell
Ga naar pagina of 16
1 2. Brief description 214430 The HR90 radiator controller is certified by eu.bac. With the electronic radiator controller , you can set your room temperature exactly to your requirements while additionally saving energy . Please note: The HR90 radiator controller does not directly switch your boiler on/off.
2 3. Device overview Operating elements and display 8 5 7 3 2 1 4 11 10 9 6 PROG AU TO MANU OK ECO 1 Heating period/setback period in hours 2 Day of the week 1 ... 7 (Monday ... Sunday). Displayed only while the time program is being programmed 3 T empera ture display: e.
3 1 . Pull off the adjustment dial. T o do so, start at the notch on the bottom of the device. 2 . If used, unscrew any fastening screws from the batter y compartment. 3 . Release the lock and fold out ba ttery spring. The batter y compartment is now accessible.
4 Selecting the adapter The radiator controller fits on common radiator valves of the type M30 x 1.5. Adapters are required for some valve types. 1 . Check whether an ada pter is required and, if necessary , select the appropriate adapter . Brand Illustration Adapter Honeywell- Braukmann, MNG, Heimeier , Oventrop valves M30 x 1.
5 Securing the radiator controller i The radiator controller and the batteries can be secured against removal by using the supplied screws. Setting the position of the display In order to improve the legibility the display of the radiator controller can be tilted to different positions (10°, 20°, 30°, 40°).
6 Cable connection i For further information also refer to the documentation for HCW23, RF20 and HCA30. f Connect the ACS90 cable as follows to the external sensor and window contact: HCW23 setpoint a.
7 Saving energy in ECO mode In ECO mode, the room tempera ture in automatic mode specified by the time program is lowered by 3 °C. f T o activate ECO mode, press the button A UT O/ ECO/MANU until economy is displayed. The displayed temperature is reduced by 3 °C .
8 7. Programming – T emperatures Three preset temperatures can be assigned to the set points in the time program: • Comfort temperature 1 Factory setting 20 °C • Comfort temperature 2 Factory setting 22 °C • Setback temperature Factory setting 16 °C Setting the temperatures 1 .
9 The example shows the following time program: Set- point Time T emperature 1 6:00 – 9:00 20 °C (Comfort temperature 1) 2 9:00 – 12:00 16 °C (Setback tempera ture) 3 12:00 – 14:00 20 °C (Com.
10 Deleting a setpoint f When a setpoint is not required, select the temperature setting --.- and confirm with OK . i The first setpoint cannot be deleted. Adding a setpoint 1 . T urn the adjustment dial until add new is displayed and confirm with OK .
11 9. Controller operating parameters Overview If required, the 19 basic settings (parameters) can be adjusted. Factory settings have a grey background.
12 Changing parameters 1 . Keep the PROG button pressed for at least 10 seconds until Parameter 1 flashes (left-hand digit). The right-hand digit shows the current setting. The parameter is displayed additionally in plain text. For example, the display 1 1 stands for Parameter 1 (language) with Setting 1 (German).
13 Parameters 5 to 7 – Window function In order to save energy , the radia tor controller closes the radiator valve when you open a window resulting in a large drop of the temperature. When you close the window so that the temperature rises the radiator controller opens the radiator valve again.
14 10. Further functions Monitoring functions Window function If you open a window causing the temperature to drop, the radiator controller closes the radiator valve in order to save energy .
15 11. Help with problems Error table Problem/ Display Cause Remedy flashes Batteries flat Replace the batteries. e1 sensor Device defective Replace the device. e2 valve Motor can not be moved. Check the installation. The radiator stays hot The radiator valve does not close fully .
Honeywell Honeywell House Skimped Hill Lane Bracknell Berkshire RG12 1EB United Kingdom The right is reserved to make modifications that serve improvement. 50080331-001C www .hr90.info Manufactured for and on behalf of the Environmental and Combustion Controls Division of Honeywell T echnologies Sàrl, ACS-ECC EMEA, Z.
Een belangrijk punt na aankoop van elk apparaat Honeywell HR90 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Honeywell HR90 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Honeywell HR90 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Honeywell HR90 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Honeywell HR90 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Honeywell HR90 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Honeywell HR90 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Honeywell HR90 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.