METROLOGIC INSTRUMENTS, INC. MS7120 Orbit ® Present ation Laser Scanner Inst allation and User ’ s Guide 00-02408D_unit_7120_Cover_Oct_2005.qxd 10/26/2005 11:31 AM Page 1.
Copyright © 2005 by Metrologic Instruments, Inc. All rights reserved. No part of this work may be reproduced, transmitted, or stored in any form or by any means without prior w ritten consent, except by review er, who may quote brief passages in a review, or provided for in the Copy right Act of 1976.
ii T ABLE OF C ONTENTS Introduction ................................................................................................ 1 Scanner and Accessories .......................................................................... 2 Operational Notes .
iii T ABLE OF C ONTENTS Installing the Optional Wall/Counter Mount ............................................. 21 Troubleshooting Guide ............................................................................ 22 RS-232 Demonstration Program ....
1 I NTRODUCTION Orbit ® is an aggressive, omnidirectional laser bar code scanner. Lightweight and rugged, Orbit is small in size, but BIG in performance. Designed for applications where counter space is limited, Orbit is the ideal presentation scanner for retail, convenience, liquor and specialty stores.
2 S CANNER A ND A CCESSORIES B ASI C K IT Part # Description MS 7120 Orbit ® Presentation Laser Scanner 00-02407 MetroSelect ® Programming Guide 00-02408 MS 7120 Installation and User’s Guide* * Avai labl e on th e Metro logic website - www.metro logic .
3 S CANNER AND A CCESSORIES O PTIONA L A CCESSORIES Part # Description MVC** Metrologic Voltage Converter Cable +12VDC to +5.2VDC or -12VDC to +5.2VDC MX009-2** MX009 USB Converter Cable ** Contact a Metrologic customer service representative for additional information on the MVC and MX009 cable series and the host connections available.
4 I NST A LLATION FOR RS232, OCIA AND IBM 46XX I NTERFACES 1. Turn of f the host system . 2. Plug the male 10- pin RJ45 end of the PowerLink c able into the 10-pin jack on the MS7120. 3. Connect the 9 pin fem ale end of the PowerLink c able to the host device.
5 I NSTALLA TION FOR K EYBOA RD W EDGE I NTERFACE 1. Turn of f the PC/Host. 2. Connect the m ale 10-pin RJ45 end of the PowerLink c able to the jack on the MS7120. 3. Connect the L-shaped plug of the power supply into the pow er jack on the PowerLink c able.
6 I N S T A LL A T I ON FO R S T A N D A LONE K EYB O A RD I N T ERF A CE 1. Turn of f the host system . 2. Plug the male 10- pin RJ45 end of the PowerLink c able into the 10-pin jack on the MS7120. 3. Connect the PowerLink c able to the keyboard port on the host system.
7 I NSTA LLA TION N OTES FOR USB I NT ERFA CE Metrologic’s MX 009 USB cable is a device that conver ts serial RS232 form atted data to either USB Keyboard or USB Point-of Sale com munica tion protocol.
8 S CANNER P ART S Red LED On a succ essful r ead of a bar code, the red LED will turn ON . After c omm unication to the host is c omplete, the red LED will turn OFF . Refer to Visual Indicator s and Audible Indicators for additional inform ation. Green LED During norm al operation, the green LED is ON .
9 A UDIBLE I NDICATORS When the MS7120 scanner is in operation, it provides audible feedback. These sounds indicate the status of the scanner. Eight settings are available for the tone of the beep (normal, 6 alternate tones and no tone). To change the tone, refer to the MetroSelect ® Programming Guide ( MLPN 00-02407B) or the MetroSet2 help files.
10 V ISUAL I NDICA T ORS There is a red LED and a green LED on the head of the MS7120. W hen the scanner is on, the flashing or cons tant illumination of the LEDs indicates the status of the current s can and the scanner. No Red or Green LE D The LEDs will not be illuminated if the sc anner is not receiving power from the host or transf orm er.
11 F A ILURE M ODES Flashing Gree n and One Razzber ry Tone This indicates the scanner has experienced a laser subsystem f ailure. Return the unit for r epair at an authorized service center . Flashing R ed and Green and T w o Ra zz be rr y Tones This indicates the scanner has experienced a m otor failure.
12 L ABELS Each scanner has three labels on the bottom of the unit. These labels contain information such as; the model number, date of manufacture, serial number, laser class and caution statements. The following illustrations show the location and content of the three labels.
13 S CAN V OLUME S PECIFICATIONS Specific ations based on 100% UPC Bar Codes. Optimal Low Density (Default) Optimal Hi gh Density 190mm 60mm 100mm Scan Area 215mm 105mm Scan Area 60mm.
14 S CAN V OLUME S PECIFICATIONS (C ONT .) Specific ations based on 100% UPC Bar Codes. Close Normal 95mm 175mm Scan Area 60mm Scan Area 190mm 60mm 100mm.
15 S CAN V OLUME S PECIFICATIONS (C ONT .) Specific ations based on 100% UPC Bar Codes. Far 215mm Scan Area 75mm 75mm 105mm.
16 D EPTH OF F IELD BY M INIMUM B AR C OD E E LEME NT W IDTH O p tim a l Lo w D e n s ity ( D e f a u lt) Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width ABCDE F GH J K mm .13 .15 .16 .17 .19 .23 .25 .33 .
17 D EPTH OF F IELD BY M INIMUM B AR C OD E E LEME NT W IDTH Optimal Hi gh Density Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width ABCDE F GH J K mm .13 .15 .16 .17 .19 .23 .25 .33 .53 .66 mils 5.2 5.7 6.
18 D EPTH OF F IELD BY M INIMUM B AR C OD E E LEME NT W IDTH Close Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width BCDE F G H J K mm .
19 D EPTH OF F IELD BY M INIMUM B AR C OD E E LEME NT W IDTH Normal Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width ABCDE F GH J K mm .
20 D EPTH OF F IELD BY M INIMUM B AR C OD E E LEME NT W IDTH Far Distance: Scanner Face To Bar Code (mm) Width of Scan Field (mm) Minimum Bar Code Element Width ABCDE F GH J K mm .
21 I NSTALLING THE O PTIONAL W ALL /C OUNTER M OUNT Kit #45-45619 contains: a. Locking Plate [ MLPN 50-50302] ............................ Qty. 1 b. Base Cover [ MLPN 50-50301] ............................ Qty. 1 c. Wood Screw, #7 x 1.00” [ MLPN 18-18013] .
22 T ROUBLESHOOTING G UIDE The f ollowing guide is for ref erence purposes only. Contact a Metrologic representative at 1- 800-ID-METRO or 1-800-436-3876 to preser ve the limited warr anty term s on page 39.
23 T ROUBLESHOOTING G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The unit pow ers up, but does not scan and/or beep Beeper disabled. No tone selected Enable beeper.
24 T ROUBLESHOOTING G UIDE (C ONTINUED ) SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Scanner beeps at some bar codes and NOT for others of the same bar code symbology The print quality of the bar code is suspect Check print mode. The ty pe of printer could be the problem.
25 T ROUBLESHOOTING G UIDE (C ONTINUED ) Keyboard Wedge Only SYMPTOMS POSSIBLE CAUSE(S) SOLUTION The unit scans the bar code but there is no data Configuration is not correct Make sure the scanner is configured for the appropriate mode.
26 T ROUBLESHOOTING G UIDE ( CONTINUED ) R S -232 O nly SYMPTOMS POSSIBLE CAUSE(S) SOLUTION Power-up OK and scans OK but does not communicate properly to the host Com port at the host is not working o.
27 RS-232 D EMONSTRA T ION P ROGRAM If an RS-232 scanner is not communicating w ith your IBM compatible PC, key in the following BASIC program to test that the communication port and scanner are working. T his program is for demonstration purposes only.
28 A PPLICATIONS AND P ROTOCOLS The model number on each scanner includes the scanner number and factory default communications protocol. S CANNER V ERSION I DENTIFIER C OMMUNICATION P ROTOCOL ( S ) 7.
29 D ESIGN S PECIFICATIONS MS7120 S PECIFICAT IONS O PE RATI ONAL Light Source: VLD 640-660 nm Depth of Field: 0 mm to 216 mm (0" to 8.5") for 0.33 mm (13 mil) bar codes Scan Speed: 1067 scans/second Scan Pattern: 5 fields of 4 par allel lines (omnidirectional) Scan Lines: 20 Min Bar Width: 0.
30 D ESIGN S PECIFICATIONS MS7120 S PECIFICAT IONS E LECTRICA L Input Voltage: 5.2VDC ± 0.25V Power: 1.0 W typical Operating Current: 200 mA typical, 250 mA typical for IBM models DC Transformers: Class II; 5.
31 D EFA ULT S ETTINGS Many functions of the scanner c an be "program med" - that is, enabled or disabled. T he scanner is shipped f rom the factory programm ed to a set of def ault conditions. The def ault parameter of the scanner has an asterisk ( * ) in the charts on the following pages.
32 D EFA ULT S ETTINGS Paramet er Default OCIA RS-232* Light Pen IBM 46XX KBW Laser Emulat ion DTS/NIXDORF * ü NCR F ü NCR S ü Poll L ight Pe n Source ü Beeper Tone Normal üüüü ü ü Beep/Tran.
33 D EFA ULT S ETTINGS Paramet er Default OCIA RS-232* Light Pen IBM 46XX KBW Laser Emulat ion Convert EAN-8 to EAN-13 üü ü ü Transmit UPC-A Number System * üüüü ü ü Transmit UPC-A Manufa ct.
34 D EFA ULT S ETTINGS Paramet er Default OCIA RS-232* Light Pen IBM 46XX KBW Laser Emulat ion Carria ge Ret urn * üü Line Feed - di sabled by default in KB W * üü Tab Pr efi x üü Tab Suffix ü.
35 D EFA ULT S ETTINGS Paramet er De fault OCIA RS-232* Light Pen IBM 46XX KBW Laser Emulat ion Coupon Code 128 üü as code 39 üü as code 39 Progr ammable Code Lengths 7 avail.
36 1 10 S CANNER A ND C AB LE T ERMINATIONS Scanner Pinout Connections The MS7120 s canner interfac es terminate to a 10-pin m odular jack . The serial # label indicates the interf ace enabled when the scanner is shipped from the factor y . Som e units have internal jum pers that c an be moved to enable a diff erent electrical interf ace.
37 S CANNER AND C ABLE T ERMINATIONS MS7120-11 IBM 46XX/RS-232 Pin Function 1 Ground 2 RS-232 Transmit Output 3 RS-232 Receive Input 4 RTS Output 5 CTS Input 6 DTR Input 7 IBM 46XX transmit 8 IBM 46XX.
38 S CANNER A ND C AB LE T ERMINATIONS Cable Connector Configur ation The PowerLink cable is term inated with a 5-pin DIN fem ale connector on one end, and a 6-pin m ini DIN male on the other. Metrologic will supply an adapter cable with a 5-pin DIN male c onnector on one end and a 6-pin m ini DIN female c onnector on the other.
39 L IMITED W A RRANTY The MS7120 Orbit © scanners are manufactured by Metrologic at its Blackw ood, New Jersey, U.S.A. facility . The MS7120 scanners have a t wo (2) y ear limited warranty f rom the dat e of manufacture.
40 N OTICE S Notices This equipment has been tested and found t o comply with the limit s for a Class B digital device, pursuant to part 15 of the FCC rules. These limit s are designed to provide reasonable protection against harmful interference in a residential inst allation.
41 N OTICE S Achtung Die Verwendung anderer als der hier beschriebenen Steuerungen, Einstellungen oder Verfahren kann eine gefährliche Laserstrahlung hervorrufen. Der Kunde sollte unter keinen Umständen versuchen, den Laser-Scanner selbst zu w arten.
42 N OTICE S Die nachfolgende Mitteilung gilt nur für Modell Nr. MS7120-11 Zur Klassifizierung gemäß Klasse B nach FCC T eil 15, ICES-003 und EN55022, befestigen Sie den vorliegenden Ferritkern an dem mitgelieferte Pow erLink Kabel Ihres MS7120-11 Barcode Scanners.
43 N OTICE S Nota (exclusivamente para los modelos de la ser ie MS7120-11) De acuerdo con las normativas FCC apartado 15, IC ES-003 y EN55022 para la Clase B, el obturador de ferrita del PowerLink que se suministra con el modelo de lector de códigos de barras MS7120-11.
44 P AT EN T S This M ETROLOGIC product may be covered by one or more of the following U.S. Patents: U.S. Patent No.; 4,960,985; 5,081,342; 5,216,232; 5,260,553; 5,340,971; 5,340,973; 5,424,525; 5,468.
45 I NDEX A access ories .......................... 2, 3 adapter ....................... 2, 3, 5, 38 application .............................. 27 audible ..................................... 9 authorized service center ....... 11 autodiscrim inates .
46 I NDEX N norm al depth of field .............. 35 notices ................. 40, 41, 42, 43 O OCIA .............. 1-4, 28, 29, 31-36 omnidir ectional................... 1, 29 operating current .................... 30 operating tem perature .........
.
October 2005 Printed in USA 00 - 02408 D.
Een belangrijk punt na aankoop van elk apparaat Honeywell Metrologic MS7120 Orbit (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Honeywell Metrologic MS7120 Orbit heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Honeywell Metrologic MS7120 Orbit vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Honeywell Metrologic MS7120 Orbit leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Honeywell Metrologic MS7120 Orbit krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Honeywell Metrologic MS7120 Orbit bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Honeywell Metrologic MS7120 Orbit kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Honeywell Metrologic MS7120 Orbit . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.