Gebruiksaanwijzing /service van het product 40170 van de fabrikant Hunter
Ga naar pagina of 33
Ele c tr on ic/M e chani c al er most a t Mo d el 40170 ins t allat ion and op erat ion manual 42998-01 01-19-2007.
2.
3 T able of Contents Important Information.................................................. 5 T ools ............................................................................ 6 Uninstalling the Existing Unit ...................................... 9 Installing the T hermostat .
4 Congratulations! T hank you for choosing a Hunter thermostat. Y our new Hunter thermostat will provide years of reliable service and year -round energy savings . Please read this manual before beginning installation and save this booklet for complete operation instructions .
5 T his thermostat is designed to work on the following heating and cooling systems: Gas – Standing Pilot Gas – Electronic Ignition Gas – F ired Boilers Gas – Millivolt Systems Oil – F ired .
6 T his thermostat includes two #8 slotted screws and two w all anchors for mounting. T o install your new thermostat, you will need the following supplies: Flat-head screwdriver ........................................................................
7 NO TICE! Do not disconnect the wir es fr om the existing thermostat before r eading these instructions . The wires must be labeled prior to r emoval to ensur e proper r econnection.
8 UNINST ALLING THE EXISTING UNIT Y RC G W Y RC G W.
9 1. T urn the system power OFF from the existing thermostat. T urn the power to the HV A C system OFF at the main power panel or at the furnace . 2. Remove the existing thermostat cover to access the wires from the w all. (Some thermostats may have multiple covers , screws or other locking devices that must be removed or disengaged.
10 UNINST ALLING THE EXISTING UNIT , CONT . if your existing thermostat is marked ... label the wire with this sticker: G / F G G W / H W W Y / C* / M Y Y RC / VC RC RC RH / R / VR / 4 RH RH 24 V olt .
11 4. Using the provided stick ers , label each wire according to the chart. (If the terminals are not labeled, contact a qualified HV A C technician.) Note: Wire colors do not always comply with standards, so wire color should be ignored. Refer to the existing terminal designation for proper identification.
12 T op Cover T hermostat.
13 INST ALLING THE THERMOST A T INST ALLING THE THERMOST A T 1. Remove the top cover from the new thermostat by pulling the two halves apart..
14 W RC Y G.
15 2. P osition the new thermostat on the w all and pull the labeled wires through the opening. 3. If the existing holes do not match those on the Hunter w all plate , or if there are no existing holes , level the thermostat and mark the w all for two holes .
16 INST ALLING THE THERMOST A T , CONT . G RC RH Y W B O R H R C W G B O Y.
17 INST ALLING THE THERMOST A T , CONT . CONNECTING THE WIRES 1. Loosen, but do not remove , the terminal screws . Note: A jumper wire has been provided, connecting the RC and RH terminals for systems that do not provide both an RH and RC wire. If you have both an RH and RC wire, remove this jumper .
18 INST ALLING THE THERMOST A T , CONT . HG HE HP STD HE/HG Switch HP/STD Switch.
19 A TT A CHING THE THERMOST A T 1. Locate the HE/HG switch on the w all plate . Set the switch to HG for a gas furnace or oil burner . Set the switch to HE for electric furnaces . (T he switch has no effect when the system is set to cooling mode .) 2.
20 INST ALLING THE THERMOST A T , CONT ..
21 3. Insert two fresh AA alkaline batteries . 4. Align the top cover with the the w all plate , and snap the two halves together . 5. Restore power at the electrical panel or furnace .
22 AUT O ON COOL OFF HEA T SYSTEM 9 0 0 7 0 6 0 5 8 0 F an Switch System Switch Set T emperature Slider.
23 OPERA TION 1. Set the Set Temperature slider to the desired temperature . 2. T he System Switch determines the operating mode of the thermostat. Select Cool, Off, or Heat. 3. T he Fan Switch should normally be located in the Auto position. T o run the fan continuously , slide the Fan Switch to the On position.
24 INDICA TORS AND ADUSTMENT 0 5 0 6 0 7 8 0 9 0 T hermometer Battery Indicator.
25 INDICA TORS AND ADUSTMENT 1. T he Thermometer indicates the room temperature . 2. T he Battery Indicator displays two battery conditions . T he first w arning is the Weak Battery Warning , indicated by the Battery Indicator flashing once approximately every three seconds .
26 SP AN Span Adjust SP AN.
27 INDICA TORS AND ADJUSTMENTS, CONT . 1. Remove the top cover from the thermostat. 2. T o mak e your system run LONGER, turn the Span Adjust clockwise . 3. T o mak e your system run SHOR TER, turn the Span Adjust counter clockwise . 4. Reattach the top cover to the thermostat.
28 1. My heating or cooling will not turn on or off . 1 a. Check the HE/HG switch to ensure it is set to the correct position. 1 b . W ait. T here may be as much as a 4-minute delay before the system turns on or off to protect the compressor . 1 c. Check the circuit break ers and switches to ensure there is enough power to the system.
29 Is there help on the web? Y es . V isit http://www .hunterfan.com for more information. ............................................................................................. Can’t I just call someone? Sure . Our T echnical Support Group is av ailable from 8 am to 5 pm CST .
30 G Rc Rh W Y F an Relay Heat/C ool 24V Supply Cool Contactor Heat Rela y or V alve X Jumper 4-wire Heat/C ool System G Rc Rh F an Relay He at 24V Supply W Heat Relay or V alve Y Cool Contactor 5-wir.
31 WIRING DIAGRAMS Reversing V alve Compressor Contactor X F an Relay Heat/C ool 24V Supply Single-stage Heat P ump System Cool Mode Heat Mode OR W G Rc Rh O B Y X Jumper Rc R h W Heat 24V or Millivol.
32 G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only S ystem F an Relay G Rc Rh W Heat 24V Supply Heat Relay or V alve X Jumper 3-wire Heat Only S ystem F an Relay G Rc Rh Y Coo.
33 © 2007 Hunter F an Company.
Een belangrijk punt na aankoop van elk apparaat Hunter 40170 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hunter 40170 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hunter 40170 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hunter 40170 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hunter 40170 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hunter 40170 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hunter 40170 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hunter 40170 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.