2500 Frisco Avenue, Memphis, T ennessee 38114 Printed in China 41788-01 6/1/2005.
Installation Guide 82500 Infiniti™ Bath V entilator F an 41788-01 6/1/2005.
2 DISCONNECT ELECTRIC POWER SUPPL Y AND LOCK OUT SERVICE P ANEL BEFORE SERVICING UNIT W ARNING TO REDUCE THE RISK OF ELECTRIC SHOCK OR INJURY , OBSERVE THE FOLLOWING: 1. For general ventilating use only. Do not use for ventilat- ing hazardous or explosive materials.
3 x4 3/8" Cable Connector * * * NO TE: Strain relief cable connector must be installed. Not Inc luded. A B C Extra Screws x2 H E D L 77864-02 F G H I J K 03242-07-133 96261-01-000 95047-02-000 74508-03-133 95776-01-000 75184-01-133 96258-01/02/03-008 75171-01/02/03-000 x2 Included.
A1 D Back out the pre-loaded screw tips until flush with the side of the housing. Remove the motor/blower from the housing. Remove the wiring cover screw . 4 Remove packing material. A2 A3 A6 F Loosen screw securing motor . A4 A 5 Remove the pre-loaded screw tip co vers.
A7 E A8 D A9 B C A 1 0 D 5/8 1/2 5/8 1/2 A 1 1 OPTION Remove the wiring cover . Pop out the first wiring access slug. Use second if needed. Insert the strain relief into the housing and secure with the washer . Position the correct depth mark at the bottom edge of the joist–based on the thickness of your sheet rock.
0 A 1 6 D A 1 2 A 1 3 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground A 1 4 Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light T ogether *Option D E A 1 5 F Pull the wires through the strain relief.
A2 2 C1 Go to step on page 12 to attach grille . 0 0 0 0 D A 1 7 G 0 0 0 0 G D A 1 8 A2 0 O N O F F A 2 1 Connect wiring from the motor to the wiring cover plate. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing.
B3 7.25 ” 7.75 ” B1 D B2 Loosen screw securing motor . Remove the existing fan and check to make sure the opening is large enough to accommodate the new motor housing (7.25” x 7.75”) . Remove the motor/blower from the housing. Existing Construction Installation Existing F an 8 Remove packing material.
B4 B 5 B8 D B9 B C Back out the pre-loaded screw tips until flush with the side of the housing. 9 B 6 E B7 E Remo ve the wiring cover . Remove the wiring cover screw . Remove the pre-loaded screw tip co vers. 41788-01 6/1/2005 Insert the strain relief into the housing and secure with the washer .
D B 1 0 Fit housing into the opening and secure by tightening the pre-loaded screws into the joist. Note: Install the box flush with the sheetrock (ceiling). B 1 1 2 1 B 1 2 D B 1 3 D B 1 4 10 Pull the wires through the strain relief and tighten the strain relief screws.
D E F B 1 6 A 3 Pin 2 Pin Fan Motor Light Light Green Black Black White Black Black White White Bare Copper Ground B 1 5 Main Switch 1 (AC In) Switch 2 (AC In) *Option Fan & Main Light T ogether *Option D B 1 7 0 0 0 0 G D B 1 8 Install the wiring co ver plate.
B 2 0 O N O F F B 2 1 B 2 2 C1 Go to step to attach grille . 12 J C 1 T est the motor . If the motor does not run, check the plug connection. T urn on the power source. Attaching the Grille C 2 K L I 41788-01 6/1/2005 Remove the thumbscrews. Remove glass dome.
Connect wiring harness. I C 3 C 4 I Slide light mount over posts. Attach thumbscrews. WARNING: T o reduce the risk of electrical shock, all 3 thumbscrews MUST be properly installed. I J C 5 Install 2 Max 60 Watt A15 bulbs (Not Inc luded). C 6 Screw glass dome into position.
14 41788-01 6/1/2005 T rouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker.
W arranty Hunter Fan Company Bath Exhaust Fan LIMITED W ARRANTY Hunter Fan Company makes the following limited warr anty to the original user or consumer purchaser of this Hunter bath exhaust fan: If .
Een belangrijk punt na aankoop van elk apparaat Hunter Bath Ventilator Fan (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Hunter Bath Ventilator Fan heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Hunter Bath Ventilator Fan vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Hunter Bath Ventilator Fan leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Hunter Bath Ventilator Fan krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Hunter Bath Ventilator Fan bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Hunter Bath Ventilator Fan kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Hunter Bath Ventilator Fan . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.