Gebruiksaanwijzing /service van het product ic pw1 van de fabrikant Icom
Ga naar pagina of 20
INSTR UCTION MANU AL iPW1 HF/50 MHz ALL BAND 1 kW LINEAR AMPLIFIER.
R W ARNING HIGH V OL T A GE! NEVER attach an antenna or internal antenna connector during trans- mission. This ma y result in an electrical shock or b ur n. R W ARNING! NEVER carr y the linear amplifier by yourself . At least two persons must carry the linear amplifier since it weights appro x.
IMPORT ANT ...................................................... i PRECA UTIONS ................................................. i EXPLICIT DEFINITIONS .................................. ii T ABLE OF CONTENTS .................................... ii UNP A CKING .
1 1 P ANEL DESCRIPTION ■ Fr ont panel and remote controller 0 100 250 500 1K 1 .5K 0 TEMP ALC ALC ad j SWR 0 1 1.5 2 3 10 20 30 40 50 60 V D HOT I D Po 10 20 30 40 50 60 W A METER-1 METER-2 P o TEMP I D V D ALC SWR DOWN 1 .
2 1 P ANEL DESCRIPTION q PO WER SWITCH [PO WER] (p . 11) Push momentarily to tur n power ON. w TRANSMIT INDICA T OR [TRANSMIT] (p . 13) Lights green while transmitting.
q OUTPUT ANTENNA CONNECT ORS [ANT1] – [ANT4] (p . 6) Accept a 50 Ω antenna with a PL-259 connector . w A CCESSOR Y SOCKET -1 [A CC-1] A CCESSOR Y SOCKET -2 [A CC-2] Enable connection to Icom e xciters (transceivers). - See the page at right for soc ket inf or mation.
4 1 P ANEL DESCRIPTION D A CC-1 SOCKET D A CC-2 SOCKET (w/[EXCITER] is “ 1 ” ) The f ollowing descriptions are applied when the [EXCITER] s witch is set to “ 1 ” (default). When [EX- CITER] is set to “ 1&2, ” [ACC-2] functions the same as [A CC-1] abov e for the 2nd e xciter .
5 2 INST ALLA TION AND CONNECTIONS (1) Single-phase 3-wire line (200 – 240 V A C) q The green wire from the A C power cab le must be connected to the protective earth. w The blac k and white wires from the A C power cable can be connected to either terminal.
■ Gr ounding T o pre v ent electr ical shock, tele vision interference (TVI), broadcast interference (BCI) and other prob- lems, g round the linear ampli fi er through the GROUND terminal on the rear panel. F or best results, connect a heavy gauge wire or str ap to a long ear th-sunk copper rod.
■ System inter connections 1 or 2 Icom 100 W HF transceiv ers can be connected as e xciters to the IC-PW1. Non-Icom transceivers can be used, how ev er , band selection will not be synchro- nized f or each exciter . See the f ollo wing diag r ams f or making connections be- tween the IC-PW1 and an e xciter (transceiv er).
8 2 INST ALLA TION AND CONNECTIONS • Using 2 Icom exciter s (transceivers) The f ollowing connections also apply to trans- ceiv ers having multiple antenna connectors f or speci fi ed bands (e.
9 2 INST ALLA TION AND CONNECTIONS • Using 1 Icom and 1 non-Icom exciter s (transceivers) NO TE: The speci fi cations f or the SEND relay are 5 V DC 0.
10 2 INST ALLA TION AND CONNECTIONS The control section of the linear ampli fi er can be sep- arated from the main body , doubling as a remote con- troller . It can be placed on the e xciter or in another conv enient place. q Disconnect the A C power cab le.
■ Setting the ALC levels Bef ore fi rst applying power , make sure all connections required f or your system are complete b y referring to chapter 2. Then, reset the linear amplifier using the f ollowing procedure. NO TE: Resetting CLEARS all programmed set- tings to def ault values .
12 3 OPERA TION The IC-PW1 uses CI-V frequency data f or automatic selection of the operating band. Program the e xciter ’ s address to use this capability as f ollows: F or non-Icom exciters , the IC-PW1 cannot be con- trolled using the CI-V function, so this setting is not necessar y .
13 3 OPERA TION CA UTION: DO NO T operate the IC-PW1 before adjusting the ALC le vels properly with the [ALC adj1] and [ALC adj2] pots. (p . 11) It takes 15 sec. f or CI-V line initial settings when se veral CI-V de vices (more than 5) are connected to a CI-V line.
3 OPERA TION 14 This linear ampli fi er has v ar ious protection circuits. D ALC circuit The ALC (A utomatic Lev el Control) circuit automati- cally limits RF output power b y controlling the input le vel of the e xciter . This prev ents transmission of dis- tor ted signals when the input signal lev el e xceeds the allow able le vel.
4 MAINTENANCE 15 PROBLEM POSSIBLE CAUSE SOLUTION REF. Power does not come on when the [POWER] switch is pushed. • Cable connection is faulty. • The circuit breaker is turned OFF. • Check the connection and connection cable pins. • Check for the cause, then turn the circuit breaker ON.
5 SPECIFICA TIONS 16 ■ General • F requency cover age: 0 1.800 – 0 1.999 MHz 0 3.500 – 1 3.999 MHz 0 7.000 – 1 7.300 MHz 10.100 – 10.150 MHz 14.000 – 14.350 MHz 18.068 – 18.168 MHz 21.000 – 21.450 MHz 24.890 – 24.990 MHz * 1 28.000 – 29.
6-9-16 Kamihigashi, Hirano-ku, Osaka 547-0002 J apan A-5449G-1EX- w Printed in Japan © 1997 Icom Inc. Count on us!.
Een belangrijk punt na aankoop van elk apparaat Icom ic pw1 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Icom ic pw1 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Icom ic pw1 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Icom ic pw1 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Icom ic pw1 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Icom ic pw1 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Icom ic pw1 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Icom ic pw1 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.