ii FCC Radio Frequency Inter ference Statem ent This equipment has been tested and found t o comply with the limits for a Class B computing device, pur suant to Part 15 of the F CC Rul es. These limits are designed to provid e reasonable protection against harmful interference when the equipment is operated in a com mercial environment.
iii Table of Cont ents FCC Radio Fre quency Interfe rence Statemen t .................................................... ii Warranty ............................. ................................................................. .............. ii About the McBasic .
iv Notes.
1 Abou t the McBa sic The McBasic series consists of low-cost, IEEE 8 02.3 singl e-conversion, 1U high, standalone media conve rters. The McBasic TP/FO con verts 10Base-T twisted pair to 10Base-FL multi-mo de or single-m ode fi ber and includes one RJ- 45 connector and one pai r of S T o r SC connect ors.
2 BNC Port Termina tion McBasi c TP/BNC features a 2-position switch next to the BNC connector that a llows a thin coax ial segment to be terminated at th e port w ithout a n additional ‘ T’ connector and termin ator. If McBasic TP/B NC is attached to a mid-p oint of a th in Et her n et segment, attach a ‘T’ connect or to th e BNC port.
3 About Link Integrity During normal operation, link integrity pu lses are transmitted by all point-to-point Ethernet devices. When an IM C Networks media converter rece ives valid link pulse s, it knows that the device to which it is co nnec ted is up and sending pulses, an d that the copp er or fiber c able coming f rom that device is intact.
4 Pulsing Fiber Alert Pulsing FiberAle rt minimizes t he problems as sociated with the l oss of one strand of fiber. If a strand is unavaila ble, the IMC Netwo rks device at the receiver end notes the loss of link. The device will stop transmitting data and start sending link pulses.
5 LED Operation Each McBasic fe atures diagnostic LE Ds. The following illustrations show the location of the LED s, an d othe r fe atu re s, on McBasic TP /FO and McBas ic TP/BNC. The LED fun ctio ns f or McBa sic TP/FO are as fol lows: • TP LINK Glows green if li nk is established on the TX port.
6 The LED fun ctio ns for M cBasic TP/ BNC are as f ollow s: • TP RCV Flickers amber when twisted p air port is receiv ing data . • TP LNK Glows green when a twisted pair link is established. • BNC COL Flickers re d in normal o peration indicat ing norm al collisions are bein g detecte d on the BNC segment.
7 Installat ion Tro ubles hoot ing • During installation, first test your fiber and t wisted pair c onnections with all troubleshooting features disabled. Then enable these features, if desired, just before final inst allation. This wil l reduce the in terference fr om feature s upon testing .
8 IMC Networks Technical Suppor t Tel: (949) 465-3000 or (800 ) 624-1 070 (in the U.S. and Cana da); +32-16-550 880 (Europe) Fax: (9 49) 465-3 020 E-Mail: techsuppor t@im cnetwork s.com Web: ww w.imcnetwor ks.com Spec if icat io ns Power AC Input Load: 100/240V±10 % ~ 50/60 Hz, 0.
9 Dimensions: McBasic TP/ FO 1.68”H x 4.75 ”W x 4 .95”D (4 .3 cm x 12.1 cm x 12.6 cm) McBasi c TP/BNC 1.68"H x 4.7 5"W x 4 .53"D (4.
10 Fiber Op tic Cleaning Guidelines Fiber Optic tran smitters an d receivers are e xtremely susce ptible to c ontamination by particles of d irt or dust, which can obst ruct the optic path and cause performance degradation. Good system performan ce requires clean optics and c onnector ferrules.
11 Safety Certif ications UL/CUL: Listed to Safety of Informati on Technology Equipm ent, including Electrical Business Equipment. CE: The products described herein comply with the Council Directive o.
19772 Pauling • Foothill Ranc h, CA 92610-26 11 USA TEL: (94 9) 465 -3000 • FAX: (949 ) 465-3 020 www.imcnetworks.com © 2008 I MC Networks. Al l rights r eserved. The info rmation in this docum ent is subject to change with out no tice. I MC Networks assumes no responsibili ty for an y errors that may appear in this document.
Een belangrijk punt na aankoop van elk apparaat IMC Networks SP50 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen IMC Networks SP50 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens IMC Networks SP50 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding IMC Networks SP50 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over IMC Networks SP50 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van IMC Networks SP50 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de IMC Networks SP50 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met IMC Networks SP50 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.