INTERMEZZO 1.2s Subwoofer Ser vice Manual Infinity Systems, Inc 250 Crossways P ark Dr . W oodbury , New Y ork 11797 REV 4 5 /200 5.
INTE R ME Z ZO 1. 2s CONTENTS SPECIFICATIONS ……………… …… ………… ……… ……… ……. 3 DETAILED SPECIFICATIONS …… … ………… ….…………… …… 4 CONTROLS an d CON NE CTIONS … …………… …….… .
INTERMEZZO 1.2s 3 Specifications Frequency Response: 23Hz - 130Hz (±3dB) 30Hz - 130Hz (±1.5dB) Subwoofer Amplifier Output: 850 watts continuous (In to 8 9 from 20Hz-100Hz with no more than 0.
Detailed Specifications INTERMEZZO 1.2s 4.
INTERMEZZO 1.2s 5 Detailed Specifications (Cont.).
INTERMEZZO 1.2s 6 Controls and Connections.
INTERMEZZO 1.2s 7 Controls and Connections (Cont.).
INTERMEZZO 1.2s 8 Controls and Connections (Cont.).
INTERMEZZO 1.2s 9 Controls and Connections (Cont.).
INTERMEZZO 1.2s 10 Operation The operation of the Intermezzo1.2s subwoofer with regards to the proper settings for the Room Adaptive Bass Optimization System, or R.A.B.O.S., is thoroughly covered in the Owner ’ s guide, p art# 336204-001. For service purposes, the R.
INTERMEZZO 1.2s 11 Mechanical/P ackaging P arts List Ref No. Description P art Number MECHANICAL 1 GASKET , REAR 331 106-001 2 12” Woofer C.M.M.D. Shielded, DCR 7.6 ohms ±10%, 335036-001 3 RABOS ASSEMBL Y 336202-001 4 SCREW , 8-32 x .5 BLK, MS,PPH (16) 900201-008 5 GRILLE CUP (14) 333249-003 6 Front BAFFLE 335270-001 7 SCREW , 6-32 x .
INTERMEZZO 1.2s 12 Exploded V iew 1 2 3 (ROTATED) 4 5 7 GRILLE, WAR M PLATINU M 335735-040 GRILLE, MIDNIGHT BLUE 335735-050 GRILLE, RI CH BURGUNDY 335735-060 AMPLIFI ER (NOT FOR SALE) INTERMEZZO 1.
INTERMEZZO 1.2s 13 P ackaging V iew 16 18 17 11 8 9 13 10 12 14 00450 15.
INTERMEZZO 1.2s 14 T est Set Up and Procedure The operation of the Intermezzo 1.2s subwoofer ,and the proper settings for the Room Adaptive Bass Opitmization System, or R.A.B.O.S., is thoroughly covered in the Owner ’s guide, part #336204-001. For service purposes, the R.
Serv ice Bulletin Serv ice Bul l etin I N F2001- 04 Rev 2 – M ay 2005 W ar r anty labor r ate: M I N OR r epai r To: All I nfinity Ser vic e Center s M odel : I nterl ude and I nterm ezz o I L50, I L60, I L100s, I L120s , I M 1.
8) Connect the s ubwoofer am pli fier to an AC power sour ce; tur n the unit ON . M easure the DC vol tage at the “CD ± ” wi res ; it s hould be 10- 20 vol ts.
IM 1.2s A DJUST BIA S PROCEDURE (M andato ry w hen any ou tp ut M OSFET tran si sto rs Q305,310,320,321,306, 307,311,312 are r epl aced ) 1. Ampl ifier shoul d be unplugged and OF F. 2. Rem ove Amp as sem bly from cabi net, follow ing the i nstr ucti ons on Page 12.
Electrical P arts List P art# Reference Designator Qty Description Linear Amplifier/Regulator Board Semiconductors DS0001 D301,D302,D303,D304,D305, 24 RECT , 100mA 75V SIGNAL 1N4148T D306, D307,D308,D.
Electrical P arts List (Cont.) P art# Reference Designator Qty Description CF0146 C361 1 CAP , F 6.8UF 250V 10% 27MMLS CC0059 C304 1 CAP , CA .1UF 100V 20% Resistors RC0004 R399 1 RES, CF 1M0 1/4W 5% .
Electrical P arts List (Cont.) P art# Reference Designator Qty Description RC0229 R3103 1 RES, CF 200K 1/2W 5% RP0056 RP301,RP302 2 POT , 5K 8MM HOR T OP ADJ/COVER RW0022 R346,R347,R393,R394 4 RES, WW.
Electrical P arts List (Cont.) P art# Reference Designator Qty Description RX0046 R421 1 RES, MO 47K 1W 5% Capacitors CC0040 C409 1 CAP , CA 4700PF 100V 10% CC0087 C421 1 CAP , CA .
Electrical P arts List (Cont.) P art# Reference Designator Qty Description 480090 1 SUB, #18R 9 187X032/1/4STRP 480097 1 SUB, #18B 9 187X032/1/4STRP 540124 L501 1 IND, CHOKE CM 500103 T501 1 XFMR, 60HZ 24V 1.1V A 810088 1 MET , HTSNK 1X2 BRIDGE For D501 JH0008 J502 1 CNCTR, HEADER 5PIN .
RC0039 R165,R170,R173 3 RES, CF 2K2 1/4W 5% RC0083 R149,R150,R158 3 RES, CF 100K 1/4W 5% RC01 1 1 R143,R148 2 RES, CF 680R 1/4W 5% RC01 15 R167 1 RES, CF 47K 1/4W 5% RC0135 R168 1 RES, CF 150K 1/4W 5%.
Electrical P arts List (Cont.) P art# Reference Designator Qty Description Resistors RC0148 R210 1 RES, CF 10M 1/4W 5% RM0001 R207,R208 2 RES, MF 1K00 1/4W 1% RM0002 R200,R201,R214,R216,R220, 10 RES, .
Electrical P arts List (Cont.) P art# Reference Designator Qty Description Miscellaneous 480033 3 SUB, #18R 4 1/4 187X032/187X032 1PC. IEC LIVE T O FUSE HOLDER; 1PC.
HS0090 2 SCREW , M3X16MM P AN PHIL BLK T O ALIGN SR0041 HW0004 8 W ASHER, SPLIT #6 ZNP TO MOUNT POWER SUPPL Y AND LINEAR BOARD HW0040 1 W ASHER, FLA T #8 NYLON 3/8 USED TO MOUNT U BRACKET TO ENCLOSURE MM0071 1 MISC, CUP GASKET INTERMEZZO 1.
AC Filter 27 INTE RMEZZO 1. 2s.
F eature 28 INTE RMEZZO 1. 2s.
RABOS 29 INTE RMEZZO 1. 2s.
Power Supply 30 INTE RMEZZO 1. 2s.
Linear Board 31 INTE RMEZZO 1. 2s.
Power Supply 32 INTE RMEZZO 1. 2s.
Linear Board 33 INTE RMEZZO 1. 2s.
Integrated Circuit Diagrams FOT O, M O C3012, 4N35 U304, 100 OPAM P, QUAD, 14 PIN, LM324N , TL074/84 U306, 301, 104, 101, 102, 103, 200 TRA NS, NPN , TO 92, 2N 4401, 2N5551T R, 2N5551, 2N 555, Q314, 3.
Interm e zzo 1. 2s Schem atics 35.
Interm e zzo 1. 2s Schem atics 36.
Interm e zzo 1. 2s Schem atics 37.
Interm e zzo 1. 2s Schem atics 38.
Interm e zzo 1. 2s Schem atics 39.
& RABOS Gain PCB Interm e zzo 1. 2s Schem atics 40.
41.
Interm e zzo 1. 2s Schem atics 42.
Een belangrijk punt na aankoop van elk apparaat Infinity IL60 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Infinity IL60 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Infinity IL60 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Infinity IL60 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Infinity IL60 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Infinity IL60 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Infinity IL60 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Infinity IL60 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.