Gebruiksaanwijzing /service van het product TD-41ZDW van de fabrikant Amtrol
Ga naar pagina of 16
BOILER MA TE TM TOP-DOWN INDIRECT -FIRED W A TER HEA TERS WITH TOP-MOUNTED COIL The heat transfer medium should be water . If any product other than water is used, it must be a non-toxic fluid suitable for human ingestion as determined by the FDA Y our AMTROL BOILER MA TE™ has been carefully assembled and factory tested.
-2- 1. GENERAL SAFETY INFORMA TION ...................................................................................... 3 2. PRE-INST ALLA TION CHECKLIST ........................................................................................ 4 Important Steps and Decisions Required Befor e Installation 3.
-3- IMPOR T ANT GENERAL SAFETY INFORMA TION - ADDITIONAL SPECIFIC SAFETY ALER TS APPEAR IN THE FOLLOWING INSTRUCTIONS EXPLOSION HAZARD: DO NOT INST ALL TO A HIGH PRESSURE STEAM BOILER (greater than 15 psig). AN EXPLOSION COULD OCCUR. EXPLOSION HAZARD.
-4- j THIS PRODUCT MUST BE INST ALLED AND MAINT AINED BY A LICENSED PROFESSIONAL. IN ADDITION TO THE INSTRUCTIONS IN THIS MANUAL, FOLLOW ALL APPLICABLE LOCAL AND ST A TE CODES OR IN THE ABSENCE OF SUCH CODES, THE CURRENT EDITIONS OF THE NA TIONAL PLUMBING CODE AND THE NA TIONAL ELECTRIC CODE.
-5- TD-7Z, TD-41Z, TD-7ZDW , TD-41ZDW COMPONENTS CHECKLIST The following is a checklist of components requir ed for proper installation of these BOILER MA TE™ models, both Priority and Non-Priority: A. Separate circulator • 1 each - circulator (4-8 gpm) • 1 each - positive shut-of f weighted check valve B.
-6- A. General Installation Requir ements 1. Do not "short circuit" the boiler Do not connect boiler supply and return lines to the same section or in the same flow circuit in a boiler , because the boiler water returning from the BOILER MA TE™ will "short circuit" and exit the boiler too cold for pr oper heat transfer .
-7- B. PIPING PIPING SHOULD BE ACCOMPLISHED WITH UNIONS. Step 1 - Locate the BOILER MA TE™ near boiler . Step 2 - Connect the cold water piping. a. Shut off the cold water supply at the main shut-of f valve. b. Drain existing domestic water system. Open 1 or more system faucets to pr event vacuum.
-8- Step 5 - Connect boiler supply pipe. Figure 1. a. Shut off the cold water supply valve to the boiler , and drain it using a hose attached to the drain valve at the boiler . b. When the boiler system piping is drained, cut the piping to accommodate the supply line tee.
-9- the service switch). c. Switch of f the branch cir cuit breaker . Step 2 - Remove electrical box cover . Step 3 - Remove existing wir e fr om boiler aquastat terminal C1 and connect to terminal #2 on DPDT relay . Step 4 - Install wire fr om DPDT relay terminal #1 to boiler aquastat terminal C1.
-10-.
- 11 - The BOILER MA TE™ is intended to pr ovide a tank service life of many years. Components, however , may be subject to failur es that requir e service. Failure to use the corr ect procedur es or parts in these circumstances may make the unit unsafe.
-12- RESIDENTIAL BOILER MA TE™ CLASSIC (TD-7Z and TD-41Z) ELECTROCUTION HAZARD. THE BOILER MA TE™ MUST BE ELECTRICALL Y GROUNDED. NOTES: 1. THE BOILER MA TE™ MUST BE ELECTRI- CALL Y GROUNDED AND INST ALLED IN ACCORDANCE WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NA TIONAL ELECTRIC CODE.
- 13 - PROBLEM CAUSE SOLUTION 1. No hot water at faucet. 1. Boiler does not operate. 1. a. Press reset button on boiler . b. Check main cut-off switch. c. Check fuse. 2. Circulator does not operate. 2. a. Check power supply . b. Check shaft coupling. c.
-14- DA TE SERVICE PERFORMED COMMENTS CONTRACTOR 9. SERVICE RECORD.
AMTROL ® BOILERMA TE ™ CLASSIC AND TOP-DOWN™ LIMITED PRODUCT WARRANTY This W arranty cannot be transferred - it is extended only to the original Purchaser or First User of the Product. By accepting and keeping this Product you agree to all of the warranty terms and limitations of liability described below .
West W arwick, Rhode Island 02893 Part #: 9040-628 REV B (7/04) -16-.
Een belangrijk punt na aankoop van elk apparaat Amtrol TD-41ZDW (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Amtrol TD-41ZDW heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Amtrol TD-41ZDW vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Amtrol TD-41ZDW leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Amtrol TD-41ZDW krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Amtrol TD-41ZDW bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Amtrol TD-41ZDW kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Amtrol TD-41ZDW . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.