Gebruiksaanwijzing /service van het product D20 van de fabrikant JLA
Ga naar pagina of 37
D20 Installation Manual W ARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death. — Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.
Retain This Manual In A Safe Place For Futur e Refer ence This product embodies advanced concepts in engineering, design, and safety . If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment.
IMPOR T ANT YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y OR THE STEAM SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) ST ANDARDS.
W ARNING The dryer must never be operated with the back guard removed. PERSONAL INJURY OR FIRE COULD RESUL T . IMPOR T ANT PLEASE OBSER VE ALL SAFETY PRECAUTIONS displayed on the equipment and/or specified in the installation manual included with the dryer .
SECTION I IMPOR T ANT INFORMA TION ............................................................................... 2 A. Receiving and Handling ............................................................................................................
2 SECTION I IMPOR T ANT INFORMA TION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery , the dryer and packaging, and wooden skid should be visually inspected for shipping damage.
3 B. SAFETY PRECAUTIONS W ARNING : For your safety , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury , or loss of life. W ARNING : The dryer must never be operated with the back guard removed.
4 W ARNING : DO NOT dry mop heads. Contamination by wax or flammable solvents will create a fire hazard. W ARNING : DO NOT use heat for drying articles that contain plastic, foam, sponge rubber , or similarly textured rubber materials. Drying in a heated basket (tumbler) may damage plastics or rubber and may be a fire hazard.
5 SECTION II SPECIFICA TIONS A. SPECIFICA TIONS * Contact factory for information not listed, 3-phase (3ø) figures shown are for 4-wire service, non-reversing. NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation.
6 NOTE : Manufacturer reserves the right to make changes in specifications at any time without notice or obligation. Specifications D20.
7 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.
8 B. LOCA TION REQUIREMENTS Before installing the dryer , be sure the location conforms to local codes and ordinances. In the absence of such codes or ordinances the location must conform with the National Fuel Gas Code ANSI.Z223.1 LA TEST EDITION, or in Canada, the installation must conform to applicable Canadian Standards: CAN/CGA-B149.
9 C. DR YER ENCLOSURE REQUIREMENTS Bulkheads and partitions should be made of noncombustible materials and must be located a minimum of 6-inches (15.24 cm) above the dryer ’ s outer top; except along the front of the dryer which may be closed if desired.
10 D. FRESH AIR SUPPL Y REQUIREMENTS The D20 air supply (make-up air) must be given careful consideration to assure proper performance of each dryer . An unrestricted source of air is necessary for each dryer . As a general rule, an unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1/4 square feet (0.
11 E. EXHAUST REQUIREMENTS DO NOT use a nonmetal flexible vent or a metal vent that is smaller than 4” (10.2 cm) in diameter or exhaust hoods with magnetic latches. DO NOT exhaust dryer into a chimney , furnace, cold air vent, attic, crawl space, or any other vent used for venting.
12.
13 IMPOR T ANT VENTING REMINDERS 1. Ductwork size and installation should be done by a qualified professional. 2. The dryer must be exhausted to the outdoors. 3. Ductwork should be routed as short as possible to the outdoors with as few elbows as possible.
14 F . ELECTRICAL INFORMA TION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms to local and state regulations or codes.
15 2) Electric Models ONL Y ALL electrically heated dryers must be connected to the electric service shown on the dryer ’ s data label, which is affixed to the upper left area of the inner back panel. The connecting wires must be properly sized to handle the rated current.
16 If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer .
17 b. Electric Models Only 1) Single-Phase (1ø) W iring Connections/Hookup If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel.
18 If local codes permit, power to the dryer can be made by the use of a flexible U.L. listed power cord or pigtail (wire size must conform to rating of dryer), or the dryer can be hard wired directly to the service breaker panel. In both cases, a strain relief must be installed where the wiring enters the dryer .
19 0 2 D ) R E Y R D R E P ( S N O I T A C I F I C E P S E C I V R E S L A C I R T C E L E : S E T O N . A . B . C y e h t d e s u e r a s e s u f n e h W e b t s u m s s a l c , g n i t i m i l t n e.
20 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms to local and state regulations or codes.
21 2. T echnical Gas Data a . Gas Specifications * Measured at outlet side of gas valve pressure tap when gas valve is on. b. Gas Connections Inlet connection ------------- 3/8” N.P .T . Inlet supply size ------------- 3/8” N.P .T . (minimum) Btu/hr input (per dryer) ---- 40,000 (10,080 kcal/hr) * Drill Material Size (D.
22 3. Piping Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LA TEST EDITION, or in Canada, CAN/CGA-B149.
23 Consistent gas pressure is essential at ALL gas connections. It is recommended that a 1/2-inch (12.7 mm) pipe gas loop be installed in the supply line servicing a bank of dryers. An in-line pressure regulator must be installed in the gas supply line (header) if the (natural) gas pressure exceeds 12.
24 H. PREP ARA TION FOR OPERA TION/ST AR T -UP The following items should be checked before attempting to operate the dryer: 1. Read ALL “ CAUTION ,” “ W ARNING ,” and “ DIRECTION ” labels attached to the dryer .
25 I. PREOPERA TIONAL TESTS ALL dryers are thoroughly tested and inspected before leaving the factory . However , a preoperational test should be performed before the dryer is publicly used. It is possible that adjustments have changed in transit or due to marginal location (installation) conditions.
26 J. SHUT DOWN INSTRUCTIONS If the dryer is to be shut down (taken out of service) for a period of time, the following must be performed: 1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker . 2. Discontinue the heat supply: a.
27 SECTION IV SER VICE/P AR TS INFORMA TION A. SER VICE 1. Service must be performed by a qualified trained technician, service agency , or gas supplier .
28 SECTION V WARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS 1. Before any dryer leaves the factory test area, a warranty card is placed on the back side of the main door glass.
29 SECTION VI ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location.
30 90 DA Y S Inspect and remove lint accumulation in customer furnished exhaust ductwork system from dryer ’ s internal exhaust ducting. W ARNING : THE ACCUMULA TION OF LINT IN THE EXHAUST DUCTWORK CAN CREA TE A POTENTIAL FIRE HAZARD. W ARNING : DO NOT OBSTRUCT THE FLOW OF COMBUSTION AND VENTILA TION AIR.
31 SECTION VII DA T A LABEL INFORMA TION A. DA T A LABEL When contacting the reseller certain information is required to insure proper service/parts information. This information is on the data label located on the left side panel area behind the control (access) door .
32 THE DA T A LABEL 1. MODEL NUMBER The model number is a manufacturers number , which describes the size of the dryer and the type of heat (gas, electric, or steam). 2. SERIAL NUMBER The serial number allows the manufacturer to gather information on your particular dryer .
ADC 113396 1 - 10/30/02-25 2* 12/03/02-250.
Een belangrijk punt na aankoop van elk apparaat JLA D20 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen JLA D20 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens JLA D20 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding JLA D20 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over JLA D20 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van JLA D20 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de JLA D20 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met JLA D20 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.