Gebruiksaanwijzing /service van het product PUB-00281 van de fabrikant JMR electronic
Ga naar pagina of 33
F F o o r r c c e e 4 4 G15 & G15+ RAID Systems 15-bay Rackmount and T ower Enclosures Installation Guide May 31, 2002 • Revision A Patent Pending.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A II Copyright Copyright 2000, 2001 by JMR Electronics, Inc. All Rights Reserved.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A T able of Contents 1. Intr oduction FOR TRA Product Family Features . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 FOR TRA Force 4 G15 RAID System Components .
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A Option Settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-4 Delayed Start Option Jumper . . . . . . . . . . . . . . . . . . . .
The FOR TRA F F o o r r c c e e 4 4 G15 & G15+ RAID Systems are prepackaged 2G Fibre to 2G Fibre RAID solutions designed to be used with the included Intel PCI Dual 2G Fibre Channel host controller to provide a high-end RAID system solution.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A FOR TRA F F o o r r c c e e 4 4 products use advanced mid-plane technology developed by JMR, which allows power supplies, drives, and all other enclosure components to interface into a single board.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A T ower Specifications Dimensions/Weight Unit W eight 43 lbs. (19.5kg) Height 20-1/2" (521mm) W idth 9-5/8" (235mm) .
ID Selection 0-127 device ID addresses are addressable and can be easily set-up via ID rotary switches located on the personality modules. For specific connection and installation information, refer to Chapter 4 .
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 2-1 This chapter covers specification information for all FOR TRA F F o o r r c c e e 4 4 G15 T ower and G15+ Rackmount or T ower enclosures.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A Disclaimer The original product packaging has been tested and is safe under normal shipping circumstances. Reshipping the product without using the original product packaging will void the warranty .
SYS-FL T The SYS-FL T LED on the back of the unit indicates an error on the SES bus. It also indicates whether an active loop connection is established.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 3-1 This chapter covers Fibre Channel device installation for both the FOR TRA F F o o r r c c e e 4 4 G15 and G15+ rackmount and tower enclosures.
Follow the steps in reverse to reinstall. Drive Installation Device mounting screws are included with the unit for device mounting. The JMR part number for the #6-32" mounting screws is HDS-01906. 1. After removing the canister , place it on a static free surface along with the device to be installed.
4. Repeat steps 1 through 3 until all devices are installed, then move onto step 5 to complete unit setup and installation. 5. Configure ID and other options as required. See Chapter 4 for Fibre Channel device setup. 6. Install and configure SES and other optional features.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 4-1 This chapter covers Fibre Channel device configuration and option settings. The FOR TRA F F o o r r c c e e 4 4 G15 and G15+ have built-in SES on the personality card.
Setting ID Rotary switch settings only affect Slot 0 and all other slots are sequentially increased by a value of one after that slot. The ID is set sequentially starting from a base address. The base address, or starting address, is set via a 0-7 position rotary switch located on the back of the unit.
1G Option Setting By setting the rotary switch settings to “7” - “F”, the enclosure will operate in 1G mode. Both the upper set of switches and lower set of switches must be set to the same value. The drive ID’ s will revert to the default value of 0-14 and can not be changed.
Delayed Start Option Jumper Header W1 pins 1 & 2. Jumper on = enabled. Jumper off = disabled (default). Remote Start Option Jumper Header W1 pins 3 & 4. Jumper on = enabled. Jumper off = disabled (default). Front Status LEDs A status indicator is located on each canister .
External I/O Connection The external I/O connections are located on the personality card There are four SFP tranceiver connectors accessible from the rear of the unit. CH-A and CH-B (T op) Input and output connections for Loop 1. These are SFP (2Gb/s) transceiver connectors used to connect to a host system or to an expansion chassis.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A Mute This is a push button used to silence the Audible Alarm. SYS Activity LED This is an LED for SES that will blink wheneve.
This chapter covers all operations of the blowers for FOR TRA F F o o r r c c e e 4 4 G15 and G15+ units. Refer to Chapter 1 for blower specifications.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 5-2 User ’ s removing or installing a blower must be awarre of the blower access hole. Contact with the access hole must be avoided while the blower is running to prevent injury .
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 6-1 This chapter covers all operations of the power supplies. For operation, the AC cord (included) must be connected to the AC Inlet on each supply , and the power supply must be switched ON.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A Low Power Mode (Standby Power) When both power supplies are turned off, the unit will switch to low power or standby mode and the power supply fans will continue to run.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 7-1 This chapter covers the installation of the Rackmount enclosure into a standard 19" (483mm) wide and 30" (762mm) to 36" (914mm) deep cabinet that meets the EMA/RETMA standards.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 7-2 Rail Mounting Kit Hardware • T en #10-32 Screws • Four each #8-32 Screws/W ashers/Nuts Spare Hardware Parts Check with a JMR Sales Representative for pricing and availability of spare hardware parts.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 2. Affix the extension bracket to the rear of the unit using two #10-32 screws. There are 3 holes in the extension bracket for mounting. Depending on the hole pattern that is being used in the cabinet, two holes should always be available for securing the extension bracket.
4. Slide the unit into the cabinet and secure it to the cabinet with a single #10-32 screw on each side. 5. Snap the end cap over the screw on each side of the unit to finish the installation.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 8-1 For bus management, the FOR TRA F F o o r r c c e e 4 4 G15 and G15+ 2G Fibre channel enclosures have a built-in SES processor designed to meet the SFF-8067 specification.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 9-1 This chapter covers the installation of the Intel PCI RAID Controller that is shipped with the FOR TRA Force 4 G15 and G15+ RAID Systems.
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A 10-1 For current information on this product, including updates to the manual and technical support related issues, please contact the sales support section of our web page at www .
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A A-1 Drive Manufacturers Fujitsu Internet Address: www .fcpa.com Hitachi Internet Address: www .hitachi.com IBM (International Business Machines Corporation) Internet Address: www .
FORTRA FORCE 4 G15 & G15+ RAID System Installation Guide Rev A Host Bus Adapter Manufacturers Adaptec, Inc. Internet Address: www .adaptec.com Antares Microsystems Internet Address: www .antares.com Emulex Corporation Internet Address: www .
Een belangrijk punt na aankoop van elk apparaat JMR electronic PUB-00281 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen JMR electronic PUB-00281 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens JMR electronic PUB-00281 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding JMR electronic PUB-00281 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over JMR electronic PUB-00281 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van JMR electronic PUB-00281 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de JMR electronic PUB-00281 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met JMR electronic PUB-00281 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.