Evaluation Board User Guide UG-002 One T echnology Wa y • P. O . Bo x 9106 • Nor wood, MA 02062- 9106, U.S . A. • Te l : 781.329. 4700 • Fax : 781. 461.3113 • www . a na l og .c o m Ev aluating the AD9551 Multiservi ce Clock Gener ator See the last page for an impo rtant warning and disclaimers.
UG-002 Evaluation Board User Guide Rev. 0 | Page 2 of 12 T ABLE OF CONTENTS Fea tures .............................................................................................. 1 General Descr iption ...........................................
Evaluation Board User Guide UG-002 Rev. 0 | Page 3 of 12 EV ALUA TION BOARD HARDW ARE The following instruc tions are for setting u p the physical connection s to the AD9551 evaluation board . SETTING UP THE POWER AND PC C ONNECTIONS Set up the power and PC conn ections as follows: 1.
UG-002 Evaluation Board User Guide Rev. 0 | Page 4 of 12 EV ALUA TION BOARD SOFTW ARE The instruc tions included in this se ction are for setting u p the AD9551 evaluatio n board softwar e. INSTALLING THE SOFTWARE Do no t connect the evalua tio n board until the softwa re installation is complete .
Evaluation Board User Guide UG-002 Rev. 0 | Page 5 of 12 GUIDE TO PROGRAMMING THE AD9551 The AD9551 can be programmed via an S PI port or by settin g the logi c leve ls o n the fre que nc y s e le c t pi ns of the d evice. T o p r og r a m the device using the serial port, the evaluation board soft war e m us t be in stalled .
UG-002 Evaluation Board User Guide Rev. 0 | Page 6 of 12 SOFTW ARE OPERA TION The main window o f the AD9551 evaluation board softwar e is com pri sed o f sub section s tha t co rr espo nd t o the ma jor functio nal blocks of the AD9551 (see Figu re 4 ).
Evaluation Board User Guide UG-002 Rev. 0 | Page 7 of 12 MENU BAR OF MAIN WINDOW File Menu The File menu allows you to load a previously saved AD9551 setup file or to save a new AD9551 setup file. A setup file (.S TP) is a text file that contains the AD9551 register setup file, plus any evaluation board se ttings.
UG-002 Evaluation Board User Guide Rev. 0 | Page 8 of 12 BUTTON BAR OF MAIN WINDOW The button s desc ribed i n this se ct ion pro vide easy access to common fea tures. Load and Save Clicki ng Loa d and Save allows you to lo ad and s ave an AD95 51 se tup f i le.
Evaluation Board User Guide UG-002 Rev. 0 | Page 9 of 12 DLL Window Clicki ng Cl ick f o r De ta ils in the DLL box of t he m ain w ind ow accesses the DL L window (see Fi gu re 11 ). This window can be used to m an uall y ov errid e the a u to ma tic time ali gnme nt between the REF A and REF B clock input signals to the PLL1 phase detector .
UG-002 Evaluation Board User Guide Rev. 0 | Page 10 of 12 Feedback Window Clicki ng Cl ick f o r De ta ils in the Feed bac k D ivide r bo x o f the main window accesses the Fee db ac k window , which allows you to change the feedback divider settings (see Fi gu re 1 5 ).
Evaluation Board User Guide UG-002 Rev. 0 | Page 11 of 12 7. The Calcul a to r window , shown in Fi gure 21 , appears. 08129-022 Figure 21. Calcul ator Window 8. T ype 122.88 into the Ref A Base Fr equenc y : b ox and 122.88 int o the Outp ut 1 Base Fr equen cy : box.
UG-002 Evaluation Board User Guide Rev. 0 | Page 12 of 12 08129-026 08129-027 Figure 25. Register Debug Window Figure 26. Input PLL + DC XO Window 11. Bit 3 o f Register 0x17 mus t be set to 1 to enable the PLL locked pin as a test port. By defaul t, the 26 MHz cr ystal frequency is presen t at the out put.
Een belangrijk punt na aankoop van elk apparaat Analog Devices UG-002 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Analog Devices UG-002 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Analog Devices UG-002 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Analog Devices UG-002 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Analog Devices UG-002 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Analog Devices UG-002 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Analog Devices UG-002 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Analog Devices UG-002 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.