MG-2/MG-4 GAS HO T PLA TE SER VICE MANU AL KEEP THIS MANU AL FOR TRAINING NEW PERSONNEL 1-800-KEA TING www .keatingofchicago.com Hot Plate 0107 09/07.
SECTION I INTRODUCTION General Information . . . . . . . . . . . . . . . . . . . . . . . . .1 Ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 Options . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 S tandard Features .
POST THIS LABEL IN A PR OMINENT L OCA TION ON Y OUR UNIT i IMPOR T ANT IN THE EVENT A GAS ODOR IS DETECTED, SHUT DOWN UNITS A T MAIN SHUT OFF V AL VE AND CONT ACT THE LOCAL GAS COMP ANY OR GAS SUPPLIER FOR SERVICE. FOR Y OUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE V APORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE.
I INTRODUCTION GENERAL Keating MG-2 and MG-4 Hot Plates are designed to give maximum production efficiency; delivering high quality food products. The following design features are incorporated in all Keating Hot Plates.
2 THIS HOT PLA TE MA Y NOT BE AL TERED, MODIFIED OR CHANGED IN ANY W A Y . The S tate of California enacted the California Safe drinking water and T oxic Enforcement Act of 1986, (Prop.
testing at test pressures less than to equal to 1/2 psig (3.45 KP A), hot plate must be isolated from gas supply piping. When pressure testing at test pressures above 1/2 psig (3,45 KP A), hot plate must be disconnected from gas supply piping system.
4 W ARNING PROP ANE GAS MA Y EVENTUALL Y LOSE ITS ODOR AND PRECAUTIONS SHOULD BE T AKEN TO ASSURE THA T IT IS NOT PRESENT EVEN THOUGH YOU DO NOT DETECT AN ODOR.
V SER VICE DIAGNOSIS On constant pilot models, the pilot light will be between 3/8" to 1/2" high and burn clear blue. The constant pilot consumes about 180 BTU/hr . of gas and is used to ignite the burners. A. T rouble Shooting The following diagnosis is only to be used as a guide to qualified service personnel.
6 GAS HOT PLA TE P ARTS LIST P ART ITEM DESCRIPTION MG-2 MG-4 NUMBER 1 GAS V AL VE (INFINITE CONTROL) WITH NG ORIFICE #49 CONST ANT PILOT 2 4 002666 SP ARK IGNITOR 2 4 002666 ORIFICE, HOODED, NA TURAL.
7 HOT PLA TE ASSEMBL Y NOTE: MG-4 hot plates are built as two MG-2 hot plates side by side. The MG-2 is shown here. NOTE: Part numbers correspond with the Hot Plate Parts list on p age 9.
8 VIII WIRING DIAGRAMS MG SI WIRING AND LADDER DIAGRAMS The diagrams below apply to hot plates with spark ignition (“SI”). Hot plates with const ant pilots (“CP”) do not have any electrical connections. NOTE: MG-4 hot plates are essentially two MG-2 hot plates side by side.
L IMITED W ARRANTY Keating Of Chicago, Inc. ("Keating”) warrants to the original purchaser . ("Customer"), all new Keating Fryers, Filter Systems, Griddles, Keep Krisp ® , Custom Pas.
SER VICE INFORMA TION If you have a service related question call 1-800-KEA TING . Please state the nature of the call; it will ensure speaking with the appropriate person. Have your serial and model number available when ordering parts. KEA TING OF CHICAGO, INC.
Een belangrijk punt na aankoop van elk apparaat Keating Of Chicago MG-2 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Keating Of Chicago MG-2 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Keating Of Chicago MG-2 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Keating Of Chicago MG-2 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Keating Of Chicago MG-2 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Keating Of Chicago MG-2 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Keating Of Chicago MG-2 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Keating Of Chicago MG-2 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.