Gebruiksaanwijzing /service van het product CH0136SQB (36") van de fabrikant Kobe Range Hoods
Ga naar pagina of 36
KOBE Brand Range Hood Model No.: CH013 0SQB (30'') CH013 6SQB (36'') CH014 2SQB (42'') CH014 8SQB (48'') CH-101 SERIES – 18'' HEIGHT I N S T A L L A.
.
- READ AND S A VE THES E INSTRUC T IONS - CONT ENTS IMPORTANT SAFETY I NS TRUCTI ONS ... ..... .... ..... ..... ... ERROR! BOOKMA RK NOT DEFIN ED. COM PONENTS OF PA CKAG E ...............................................................................
1 IMPORT ANT SAFETY I NST RUCT IONS - PLEASE READ T HIS SECT I O N CAR EFUL L Y BEF ORE INST ALLA T ION - W ARNING: TO REDUCE T HE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJUR Y , OBSERVE THE F OLLO.
2 W hat to Do In The Event Of a Range T op Grease Fire • SMOTHER FLAMES w i th a cl ose fitting lid , cookie sheet, or m etal tray , a nd then tu rn off the burn er . KEEP F LAMMABLE O R COMBUST IBLE MA TERIAL A W A Y F ROM FLAMES. If the fl ames do not go ou t i mm edi ate l y , EV ACUA TE THE AR EA AND CALL THE F IR E DEP AR T MENT or 91 1.
3 COMPONENTS OF PA CKAGE (Must keep a ll materi al for returns or re funds) O P T I O N A L R E C I R C U L A T I N G K I T A L S O A V A I L A B L E . F O R M O R E I N F O R M A T I O N , P L E A S E V I S I T O U R W E B S I T E W W W . K O B E R A N G E H O O D S .
4 INS T ALLATION PLEASE READ ENTIRE INSTRUCT ION BEFORE PROCEEDING Calculatio n before Installat ion To cal culate installation , p l ea se refer to Table 1.
5 SAFETY WARN ING HOOD MA Y HA VE VER Y SHARP EDGES; P LEASE WEAR PROT ECTIVE GLOVES IF IT I S NECESSAR Y TO REMOVE ANY P A RT S FOR I NST ALLING , CLE ANING OR SERVICING . NOT E: BE C AREFUL WHEN USI NG ELECT RICAL SCREWDRIVER, D AMAGE TO THE HOOD MA Y OCCUR.
6 UNDER T HE CA B INE T INS T A LLAT ION Preparatio n Before Installat ion NOTE: TO AVOID DAM A GE TO YOUR HOOD, PREVE NT DEBRIS FROM ENTERING THE VENT OPENING. • De cide the location of the venting pipe from the hood to the outside. Refer to Figure 1.
7 Ductwork Installat ion 7. Use 8” a luminum o r st eel p ipe ( fo llow bu ildi ng codes in your a rea) to c onnect the duct i ng transi tion on the hood to the ductwork above.
8 15. Inst all heati ng la mps (not pro vid ed), 120 Volt s 1 75 Watt s m ax. e ach. 16. Tu rn power ON in control panel. Ch eck all lights a n d fan operation.
9 ST AND A LO NE INST A LL ATION * * * F ol l o w th e se i ns t a l l a ti o ns o n l y i f i n s t a l l i n g wi t h a n o p t i o n al d u c t c o v e r : Preparatio n Before Installat ion NOTE : TO AVOID DAM AGE TO YOUR HO OD, PRE VENT DEBRI S FROM ENT ERIN G TH E VENT OP E NIN G.
10 2. Alig n hoo d -m ounti ng b rac ket to the two screw s on the wall and hook ho od in to pla ce. Tig hten scr ews to s ec u re hood t o t he wall . 3. For sa fety purp ose, extr a kno ckout hol e s on the back of the ho od are provi ded fo r a m o r e se cure inst all ati o n.
11 Duct Cover Installat ion 5. Use 8” a luminum or steel pipe ( f ollow b uilding codes i n y ou r area) to connect the ducting transition o n t he hood to the ductwork above . Use duct t ape to seal and secure joints as show n in Figu r e 15 . Sl i de t he du ct cover onto t he hoo d.
12 OPER A TING INSTRU CTIONS This KOBE h ood i s equipped with t ouch-sen sor s creen and fea tures 3 minute del ay shutoff, powerful centrifug al squirrel cage with b aff l e fil ters, brig ht 12-volt 20- watt hal ogen l i ghts a nd heatin g lam p cap abili ty (heating lam ps not i ncluded).
13 Turn Off After 3 Minute Delay Gently touch the symbol under the Power Control s i g n o n c e , t h e symbol f l a shes and a f t e r 3 m i n u t e s , the ho o d w i l l t u r n o f f l e a v i n g o n l y t h e sign li t . Sp e e d C o n t rol : • There are f our speeds: QuietMode™, Low, M ed ium, and High.
14 M A INTEN A NCE SAFETY WARN ING NEVER PUT YOUR HA ND INTO AREA HOU SI NG T HE F AN WHILE T HE F A N I S OPERA TING . For opt imal op eration, clea n range hood and all baf fle/spacer/f i lter/oil tunnel /oil conta i ner regul arly . T o Cle an Hood Surface CA UT ION: NEVER USE ABRAS IVE CLEANERS, P A DS, OR CLOT HS.
15 T o Rep lace Light Bulb CA UT ION: HA LOGEN L IGHT UNIT MA Y BE HOT ! W AIT UNT IL UNI T IS COOL. 1. Make sure all controls are off, and range hood is unp lu gged. 2. Place a flat-head scre wdr i ve r between light cover an d housing to rem o ve cover .
16 SPECIFICA TIONS CH0130SQB / 30” CH0136SQB / 36” CH0142SQB / 42” M O DEL / S IZE CH0148SQB / 48” DESIGN 18-Gauge Seamless Commercial S tai n less S teel CONSUMPTI O N / AM PERE 702W / 5 .
17 ME A S UREMENTS & DIA G R A M S *** In c h measurements co nverted from millimete r. In c h meas urem e nts are e stimated. - F O R U N D E R T H E C A B I N E T - MODEL NO: CH013 0SQB CH0136SQB CH0142SQB CH0148SQB 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 / 8 " ( 7 9 .
18 - F O R U N D E R T H E C A B I N E T – ( C o n t . ) 2 - 5 / 8 " ( 6 6 ) 1 - 1 / 4 " ( 3 2 ) 6 - 1 / 2 " ( 1 6 5 ) 5 - 5 / 8 " ( 1 4 3 ) 1 0 - 3 / 4 " ( 2 7 3 ) 8 - 5 / .
19 - FO R STAND ALONE ( W ITH OPT IONAL DUCT COVER) – MODEL NO: CH013 0SQB CH0136SQB CH0142SQB CH0148SQB 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 /8 " (7 9 . 5 ) 2 4 " ( 6 1 0 ) 1 8 " (4 5 7 ) 1 8 - 7 /8 " ( 4 8 0 ) 1 9 - 1 / 3 " (4 9 1 ) 1 - 1 / 4 " ( 3 2 ) 1 2 " ( 3 0 5 ) 6 " ( 1 5 2 .
20 - FO R STAND ALONE ( W ITH OPT IONAL DUCT COVER) – (Con t.) 3 0 " / 3 6 " / 4 2 " / 4 8 " 3 - 1 /8 " (7 9 . 5 ) 2 4 " ( 6 1 0 ) 1 8 " ( 4 5 7 ) 3 0 " ( 7 6.
21 Hood- Mounting Bracket 1" ( 2 5 .4) 4 " (1 0 2 ) 1 /2 " (1 3 ) 1 /3 " (8 . 5 ) 3 /1 6 " (5 ) 1/ 4" ( 6 .5 ) 1 1 /1 6 " (1 7 .
22 P A RTS LIST MODEL NO: CH0130SQB CH0136SQB CH0142SQB CH0148SQB BODY COMPONENT S NO. DESC RIPTION MOD EL/SIZE PART NO. 1 Hood Casi ng CH 101-1 2 Ducting Transiti on CH 101-2 3 Screw s (3/16” x 3/8.
23 1 2 3 4 5 9 3 8 1 0 1 1 6 1 2 1 3 1 4 1 7A 1 6 1 8 1 9 2 0 2 1 7 1 7B 1 7 1 5 2 2 2 3 Optional Duct Cover ( Sold Separately) 2 4 3.
24 Blower Assembly NO. DESCRIPTION MODEL / SIZE PART NO. 4.1 Screws (3/16 ” x 3/8”) CH101-4.1 4.2 Air Flow Grill CH101-4.2 4.3 Left Locknut CH101-4.3 4.4 Left Squirrel Cage CH101-4.4 4.5 Motor CH101-4.5 4.6 Ri ght Squirrel Cage CH101-4.6 4.7 Ri ght Locknut CH101- 4.
25 Electrical Assembly NO. DESCRIPTION M ODEL / SIZE PART NO. 21.1 Bolt CH101-21.1 21.2 Elect rical Box CH101-21.2 21.3 Screws (3/16” x 3/8”) CH101-21.3 21.4 Pow er Boa rd CH101-21.4 21.5 Elect rical Box Cover CH101- 21.5 21.6 Setup Boar d CH1 01-2 1.
26 Switch Assembly NO. DESCRIPTION MODEL / SIZE PART NO. 20.1 Screen Support CH1 01-2 0.1 20.2 Touch Scr een CH1 01-2 0.2 20.3 Sw i tch Box CH1 01-2 0.3 20.4 Sw i tch Boa rd CH101- 20.4 20.5 Sw i tch Box Cover CH1 01-2 0.5 20.6 Screw s (1/ 8” x 1/2”) CH101 -20.
27 CIRCUIT DIAGRAM MODEL NO.: CH0130SQB CH0136SQB.
28 MODEL NO.: CH0142SQB CH0148SQB.
29 DIS CL AIMER 1. CA R EFULL Y INS P ECT ALL ITEMS FOR DAMAGES B EFO RE ACCEPTING DELIVERY. NOT E A NY D A MAGES O N T HE F REI GHT BI L L OR EXPRESS RECEIPT. REQUES T NAME A ND SIGNATURE O F T HE CA RRIER’S AGENT A ND KEEP COPY T O SUPPORT YOUR CLAIM.
30 WA RRANT Y WA RRANT Y CERTIFICA T E KOBE Rang e Hoods, Inc. w arr ants all produc ts manufactur ed or sup plied by i t to b e free fro m defect s in w or km a nshi p and materi als.
31 h) for da m ag e by or resu l tin g from atte m pted repairs conducted by anyone o ther tha n our Aut horized Service Agent. 3) T he purchas er sh all be r espo nsible fo r an y expenses i n volved.
32 PRODUCT REGISTRA TION Regis ter Your Product! Any covere d failure occurrin g within t wo year s of original purch ase arising from defe ctive workmanship or m ate rial in m anu factur e will be r epaired o r at our option t he unit will be repla ced free of ch arge by an a uthorized KOBE Range Hoods Agent or KOBE Ran ge Hoods a s applicable.
KOBE Range Hoo ds 10505 Valley Blvd Suite # 302 El Monte , CA 91731 USA http:// www.KOB ERa ngeH oods.c om This KOBE hoo d i s made f or u se i n the USA and CANADA onl y . W e do not recomm end usi ng thi s hood ove rseas as t he pow er suppl y may not be com p ati bl e and may vi olate the el ectr i cal cod e of that country.
Een belangrijk punt na aankoop van elk apparaat Kobe Range Hoods CH0136SQB (36") (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Kobe Range Hoods CH0136SQB (36") heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Kobe Range Hoods CH0136SQB (36") vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Kobe Range Hoods CH0136SQB (36") leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Kobe Range Hoods CH0136SQB (36") krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Kobe Range Hoods CH0136SQB (36") bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Kobe Range Hoods CH0136SQB (36") kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Kobe Range Hoods CH0136SQB (36") . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.