Gebruiksaanwijzing /service van het product CH7642SQB van de fabrikant Kobe Range Hoods
Ga naar pagina of 35
K O B E B r a n d R a n g e H o o d Mod el No. CH76 30SQB (30”) CH7636SQB (3 6”) CH7642SQB (4 2”) CH7648SQB (4 8”) CH-176 SERIES – 10” HEIGHT INST ALLA TION INSTRUCTIONS AND OPERA T ION MA.
- READ AND SA V E T HESE INST RUCTIONS - CONT ENTS IMPOR T ANT SAFETY INSTRUC TIONS .........................................................................1 COMPONEN TS OF P A CK AGE ..................................................................
1 IMPORT A NT SAFET Y INST RUCTIONS - PLEASE READ T HIS SECT ION CARE F UL L Y BEFORE INST A LL A TION - W A RNI NG: TO REDU CE T HE RISK OF FIRE, ELECTRIC SH OCK O R PE RSONA L I N J UR Y , OBSERVE T.
2 W hat to D o In Th e Event O f a Range T op Grease Fire • SMOTHER FL AMES wit h a close f itting lid, cook i e sheet , or metal tray , and then turn of f t h e b urner .
3 COMPONENTS OF P ACKAGE (Must keep all material for re t urns or refunds) Range Hood Box Duct Co ver Box (Sold Se parately) {A} KOBE Range Ho od {B} W arranty Regis tratio n Card {C} In s truct ion M.
4 INST ALL A T I ON PLEASE READ ENTIRE INSTRUCT IONS BEF ORE PROCEEDING Calculatio n before Inst a llation T o ca lculate i n stalla t ion, please refer to T ABLE 1 or T AB L E 2.
5 SAFETY WA RNIN G H O OD MA Y HA V E VE R Y S HA RP EDGE S; PLEA S E WEA R P ROTECT IV E GLOVES IF I T IS N E CESS A RY TO REMOVE A NY P A RT S FO R INS T A LL ING , CLE ANIN G O R SERVICI NG . N O TE : BE C A REFUL WHE N U SING ELE CTRICA L SCRE WDRI V ER, D AMA GE TO THE H OO D MA Y OCCUR.
6 UNDER T HE CA B INET INS T ALLA T ION P r e p a r a t i o n b e f o r e I n s t a l l a t i o n NOTE: TO A VOI D DA M A GE T O YOUR HOOD, PREVENT DEBRI S FROM ENTERING THE VENT OPENI NG . • Decide the location of the v e nting pipe f r o m the hood to the outside.
7 4. Draw electrical wires through c a binet acces s o p ening. 5. From inside of the hood, p l a ce s crew (not provided) into the exact center of each knockout hole and secure to cabinet bottom. Once all mounting screws are in p lace, f i n ish tightening screws u n til secure.
8 A c c e s s o r i e s 9. Drop o il tunnel into recess support near re ar of hood. Refer to Figure 6. 10. Install baf f le f ilters a nd st a inless sp acer(s). Refer t o Mea sur e m ents and Dia g r a m s on pa ge 22 f or baffl e fil ter and stai nless spac e r pla ceme nt.
9 ST AND ALONE I N ST ALLA T ION *** This i n stalla t ion only applies i f installing wit h the CH1 1 20DC duct cover . P r e p a r a t i o n b e f o r e I n s t a l l a t i o n NOTE: T O A VOID DA M A GE TO YOUR HOOD, PREVENT DEBRIS FROM ENTERING THE VENT OPENI NG .
10 1. Using refere n ces in T A BLE 1 and M e asu rements and Diagrams o n pages 19-21, mark th e le ve ling point of t he hood. Position two mo unting screws (not provided) on the wall, leaving 1/8” sp a ce away from the wall.
11 D u c t C o v e r I n s t a l l a t i o n 6. Mark the p osition of t he inner duct cover- mounting bracket {J} (provided). Us e reference E from T ABLE 2 a nd M e asu rements and Diagrams on p a ge 20-21. Attach and sec ure inner du ct cover- mo unting bracket {J} with two scr e ws (not p rovided) to the wall.
12 F i n a l A s s e m b l y 14. T urn p ower O N in control panel. Check all light and fan operation. 15. Make su re to leave th is manual for the homeowner .
13 OPERA T ION I NST RUCT IONS This KOBE hoo d is equi pped with six electronic contr ols, two powerful ce ntr i fug al squirrel cages with sta i nless stee l oil t unnel, sta i nless steel b aff l e filters an d sp ace r(s), and bright 1 2- vol t 20-watt halogen lights (2 for 30” & 36” and 3 f or 42” & 48”).
14 Figure 2 1 T ur ning Fan OFF: The 3-Minute Delay fun ction w il l onl y turn off fans. The light settings w il l no t be affected by the del ay function. 3-Min ute Delay - Press Pow er Control (On/Of f) button once , the L ED lig ht f or the act i ve spee d will flash and fa ns will shut off afte r 3 m i nu tes.
15 MAINT ENA NCE SAFETY WAR NIN G NEVER PUT YOUR HA ND INTO AREA HOU SI NG T HE F AN WHILE T HE F AN IS OPERA T I NG . For optimal operation, clean ran g e hood and all baf f le/spacer/ f ilter/oil tunnel/oil cont a iner regul a rly . T o Clean Hood Surface CAUTI ON : NEVER USE A BR A S I V E CLEAN ERS , P A DS , OR CLOTHS.
16 T o Replace Light Bul b CAUTI ON : HALOGEN LIGH T UNIT MA Y BE HOT! W AI T UNTIL UNI T IS COOL. 1. Make sure all controls are of f, and range hood is unp lugged. 2. Place a flat- h ead screwdriver betwe e n light cover an d housing to remove cov e r .
17 SPECIFICA T IONS MODEL / SIZE CH76 30SQB / 30” CH76 36SQB / 36" CH76 42SQB / 42” CH76 48SQB / 48” COLOR #304 Commercia l Grade S tainles s S t eel CONSUMP T ION / AMPERE CH76 30SQB – 3.
18 MEASUREMENT S & DIAGRAMS A ll ( ) are in m illimeter . A ll inch measurement s are converted from millim e ters. Inch measurements a re esti mated.
19 A ll ( ) are in m illimeter . A ll inch measurement s are converted from millim e ters. Inch measurements a re esti mated. - FO R S T AND ALONE (WITH O P T I ONAL DUCT CO VER) - MODEL NO : .
20 Rear Knocko ut Holes 2 4 " ( 6 0 8 ) f o r 4 2 " 3 0 " ( 7 6 0 ) f o r 4 8 " 1 8 " ( 4 5 6 ) f o r 3 6 " 3 " ( 7 5 ) 3 " ( 7 5 ) 3 " ( 7 5 ) 3 " ( .
21 Hood-Mounting Bracke t DUCT COVER-MOUN T I NG BRACKET I nn er Duct Cover-Mounti ng B r a cket Outer Duct C o ver- Mounting Bracket 1 1 - 3 / 4 " ( 2 9 8 ) 1 - 3 / 1 6 " ( 3 0 ) 1 - 1 / 4 " ( 3 2 . 5 ) 8 - 5 / 8 " ( 2 1 9 ) 8 - 5 / 8 " ( 2 2 0 ) 1 1 - 3 / 4 " ( 2 9 8 ) 7/8" ( 22) 1/8" ( 4.
22 BA F FL E FIL T ER & ST AINLESS ST EEL SP ACERS 30 ″ H 00 D 42 ″ H 00 D 3 6 ″ H 00 D 48 ″ H 00 D.
23 P ART S LIST M ODE L N O.: CH 7 6 30SQB CH 7 636 SQB CH 7 642 SQB CH 7 648 SQB Body Compo nents NO. DESCRIPTION MODEL/SIZE P ART NO. 1 Screws (3/16” x 3/8”) CH176- 1 2 Hood Ca sing CH176- 2 3 H.
24 3 2 1 4 5 6 7 1 0 2 1 9 1 5 1 6 1 8 1 9 1 7 1 4 1 3 1 1 1 2 B 1 2 C 1 2 1 2 A 2 0 2 2 8.
25 Blower Assembly NO . D ESCR IP TI ON MOD EL /SI ZE P ART NO . 1 Ai r C ha mber CH 17 6- 6 .1 2 Sc re w Ca p CH 17 6- 6 .2 3 L eft S qu ir rel C age CH 17 6- 6 .3 4 L eft L o ck nu t CH1 76 -6 .4 5 Ai r Flo w G rill CH 17 6- 6 .5 6 Sc re ws ( 3 /16 ” x 3/ 8” ) CH 17 6- 6 .
26 Electrical Assembly NO . D ESCR IP TI ON MOD EL /SI ZE P ART NO . 1 Pr o ce sso r Bo ard CH 17 6- 1 5. 1 2 Tran s former CH 17 6- 1 5. 2 3 El e ct ric al Bo x CH 17 6- 1 5. 3 4 El e ct ric al Bo x Co ve r CH 17 6- 1 5. 4 5 C apa ci tor CH 17 6- 1 5.
27 CIRCUIT DIAGRAM M ODE L N O.: CH 7 6 30SQB CH 7 636 SQB MOTOR MOTOR CAPACITOR 10uF/450V CAPACITOR 10uF /450V TRANSFORMER PROCESSO R BOARD CONTROL BOARD HALOGEN LIGH T RED BLACK WHITE YELLOW GREEN B.
28 M ODE L N O.: CH 7 6 42SQB CH 7 648 SQB 120V 60Hz RED WHITE BLACK BLACK BLACK RED WHITE WHITE GREEN GREEN RED RED BROWN BROWN GREEN YELLOW WHITE BLACK RED HALOGEN LIGHT CONTROL BOARD PROCESSOR BOAR.
29 DISCLAIMER 1. C A RE FULL Y I N S PECT A L L ITE M S FOR DAMAGES BEFORE A CCE PT IN G DELI V ER Y . NOTE A NY D AMAGES O N T HE FREIGHT BI LL OR EXPRESS RE C E IP T . R EQ U E ST NA ME A ND SIGNA T URE OF T HE CA RR IER’S A GENT A ND KE EP C O PY TO SUPPORT YOUR CLAIM .
30 W ARR AN T Y W ARRAN T Y CE RTIFICA T E KOBE Range Hoods, Inc. warra n ts all products m anufa ctured o r supplied by it to b e free from de f ect s in workmanship and materials.
31 3) The purchaser shall b e responsible fo r any expenses involved in m a king the range hood readily acces si b le fo r servicin g and where t he r a nge h ood is installed outsi d e t he m a in sa.
32 PRODUCT REGISTRA T I O N Regist e r Y our Product! Any covere d f ailure occu rring wi thin two years o f original p u rchase arising f rom d ef ective workmanship o r ma terial in manu fa ctu r e .
KO BE R an g e Ho od s 10 50 5 V al le y Bl vd Su i te # 3 02 El Mo nt e, C A 9 17 3 1 USA http:// www .K OB ERan geH oods.c om Thi s KOBE ho od i s manu fa ct ur ed for use i n the USA an d C ANAD A on l y .
Een belangrijk punt na aankoop van elk apparaat Kobe Range Hoods CH7642SQB (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Kobe Range Hoods CH7642SQB heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Kobe Range Hoods CH7642SQB vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Kobe Range Hoods CH7642SQB leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Kobe Range Hoods CH7642SQB krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Kobe Range Hoods CH7642SQB bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Kobe Range Hoods CH7642SQB kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Kobe Range Hoods CH7642SQB . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.