Page 1 12821-6-0406 VENTED ROOM HEA TER MODELS RH-25-6 RH-35-6 EFFECTIVE DA TE APRIL 2006 INST ALLA TION INSTRUCTIONS AND OWNER’S MANUAL — Do not store or use gasoline or other flam- mable vapors and liquids in the vicinity of this or any other appliance.
Page 2 12821-6-0406 SECTION P AGE Important Safety Information ......................................................................................................................3 Safety Information for Users of LP Gas .............................
Page 3 12821-6-0406 • Due to high temperatures, the r oom heater should be located out of traffic and away fr om furnitur e and drap- eries. • Childr en and adults should be alerted to the hazards of high surface temperatur e and should stay away to avoid burns or clothing ignition.
Page 4 12821-6-0406 Some people cannot smell well. Some people cannot smell the odor of the chemical put into the gas. Y ou must find out if you can smell the odorant in propane. Smoking can decrease your ability to smell. Being around an odor for a time can affect your sensitivity or ability to detect that odor .
Page 5 12821-6-0406 Introduction Always consult your local Building Department regarding regu- lations, codes or ordinances which apply to the installation of a vented room heater . Instructions to Installer 1. Installer must leave instruction manual with owner after instal- lation.
Page 6 12821-6-0406 Note: Never use plastic pipe. Check to confirm whether your local codes allow copper tubing or galvanized. Note: Since some municipalities have additional local codes, it is always best to consult your local authority and installation code.
Page 7 12821-6-0406 Clearances: When facing the front of the room heater the mini- mum clearances to combustible construction (material) are the following: Right side 6 inches (152mm). Left side 6 inches (152mm). Recommend 18 inches (457mm) on left side for servicing.
Page 8 12821-6-0406 This heater must be properly connected to a venting system. This heater is equipped with a vent safety shutoff system. W arning: Operation of this heater , when not connected to a .
Page 9 12821-6-0406 1. STOP! Read the safety information to the left of this label. 2. Set thermostat to lowest setting. 3. T urn off all electric power to the appliance. (If applicable) 4. Remove access panel (front panel). 5. Push in gas control knob slightly and turn clockwise to “OFF”.
Page 10 12821-6-0406 The correct flame will be almost horizontal, blue and will extend past the thermocouple 1/4" (6mm). The flame will surround the thermocouple just below the tip. On Propane (LP-gas) slight yellow might occur where the pilot flame and the burner flame meet.
Page 1 1 12821-6-0406 T o Remove Main Burner 1. Disconnect the thermocouple and pilot supply line at the pilot burner . 2. Unscrew the nut on the orifice fitting union. Orifice fitting is threaded into the main burner . 3. Remove screw on each side of the main burner and lift out.
Page 12 12821-6-0406 INDEX NO. P AR T NUMBER DESCRIPTION 1 R-6096 Knob & Adaptor Set 2 1 1700 Control Rod Bracket 3 R-2706 ECO Switch 4 R-8195 ECO W ire Assembly 5 1 1699 Control Rod 6 R-6104 Gas .
Page 13 12821-6-0406.
Page 14 12821-6-0406 DRB-1 For V ented Room Heaters Models RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) Dir ect V ent W all Furnaces DV -25-(1, 2)SG and DV -35-(1, 2)SG Installing Optional DRB-1 Blower 1. For RH-25-(1, 2, 4, 5, 6) and RH-35-(1, 2, 4, 5, 6) , remove casing front.
Page 15 12821-6-0406 Code, CSA C22.1 , if an external electrical source is utilized. This appliance is equipped with a three-pr ong [grounding] plug for your protection against shock hazard and should be plugged directly into a pr operly grounded three-pr ong receptacle.
Page 16 12821-6-0406 Empire Comfort Systems, Inc. 918 Freeburg A ve. Belleville, IL 62220 PH: 618-233-7420 or 800-851-3153 F AX: 618-233-7097 or 800-443-8648 info@empirecomfort.
Een belangrijk punt na aankoop van elk apparaat Langley/Empire RH-35-6 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Langley/Empire RH-35-6 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Langley/Empire RH-35-6 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Langley/Empire RH-35-6 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Langley/Empire RH-35-6 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Langley/Empire RH-35-6 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Langley/Empire RH-35-6 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Langley/Empire RH-35-6 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.