Inst allation and Customization NetShelter CX Enclosures ns 143 5 a.
This manual is availab le in English on the APC W eb site (www .apc.com). Dieses Handbuch ist in Deutsch auf der APC W ebseite (www .apc.com) verfügbar . Este manual está disponible en español en la página web de APC (www .apc.com). Ce manuel est disponible en français sur le site internet d’APC (www .
Content s NetShelter CX Enclosure: In stallation, and Customization i General Information .................. ...................................... 1 Important Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Disclaimer .
NetShelter CX Enclosure: In stallation, and Customization ii Removing and Installing Fan Modules . . . . . . . . . . . . . . . . . . . . . . . . 9 Unlock the fan modu le . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 Lock the fan modul e .
1 NetShelter CX Enclosure: Installation and Cu stomization General Information Import ant Safety Information Read the instructions carefu lly and l ook at the eq uipmen t to become familiar wi th the device before trying to install, operate, service or maintain it.
NetShelter CX Enclosure: Installation and Custom ization 2 Disclaimer The information presented in this manual is not warranted by Schn eider Electric to be authoritative, error free, or complete. This publication is not meant to be a substitute for a detailed operational an d site specific development plan.
3 NetShelter CX Enclosure: Installation and Cu stomization Product Overview Description NetShelter CX enclosures are specialized enclosures with integrated cooling, noise dampening, an d power distribution for server and network applicatio ns in of fice environments.
NetShelter CX Enclosure: Installation and Custom ization 4 Product Inventory Enclosure component s † The bottom trim, leveling feet, door keys, and rack PDU power cord (not shown) are not installed and can be found inside the enclosure.
5 NetShelter CX Enclosure: Installation and Cu stomization Import ant Information To o l s Other tools required (not provided) Safety Import ant Safety Instructions Save These Instructions This manual contains important instruc tions that must be followed during installation, operation, and maintenance of the equipment.
NetShelter CX Enclosure: Installation and Custom ization 6 Configuration Before installing the enclosure, pl an the location and space needed to install equipment, and plan the ergon omics of keyboards and v ideo monitors. Impr oper airflow could damage installed components.
7 NetShelter CX Enclosure: Installation and Cu stomization Three hinges are attached to thei r mountings in the enclosure to complete door installation. 38 and 24U racks have three hinges per door . The 18U rack s have two hinges per door . Removal. 1 Press on the hidden latch under the side arm.
NetShelter CX Enclosure: Installation and Custom ization 8 Inst allation Inst allation and Setup If equipment mounting rails are adj usted from their st andard factory installed positions to a deeper position, such as in a networking appli cation, the levelling feet must be used.
9 NetShelter CX Enclosure: Installation and Cu stomization Removing and Inst alling Fan Modules Unlock the fan module Open the right hand side panel. Unscrew the thumbscrew on the right side of the fan module to unlock the fan module so it can be opened.
NetShelter CX Enclosure: Installation and Custom ization 10 Rack PDU The NetShelter CX Enclosure is pr ovided with one Basic Rack PDU. The Rack PDU distributes power to devices in the enclosure. AP9567 - North American Outlet s. The Rack PDU has fourteen (14) NEMA 5015 R outlets.
11 NetShelter CX Enclosure: Installation and Cu stomization V ertical Mounting Flanges V ertical mounting flanges come factory-installed on the enclosure in the proper position for use with rack-m ountable equipment having a depth of 800 mm (31.5 in).
NetShelter CX Enclosure: Installation and Custom ization 12 Inst alling Equipment This section provides info rmation on how t o install rack-mount equipment in the enclosure. The instructions provided with the equipment provide more detailed information.
13 NetShelter CX Enclosure: Installation and Cu stomization Equipment Planning Guidelines Please note the following guidelines for proper installa tion and operation of hardware in a NetShelter CX Enclosure.
NetShelter CX Enclosure: Installation and Custom ization 14 Dimensions Enclosure dimensions internal Reduction in internal cabinet depth in some rack unit s due to triangular protru sion of fan modu les. Dimension key . • a. 775 mm (30.5 in ) • b.
15 NetShelter CX Enclosure: Installation and Cu stomization Cable Management The NetShelter CX enclosure has a cable access opening (cable port) at the rear of the enclosure. The 38U enclosure has an additional cable port at the top for cabling from above.
NetShelter CX Enclosure: Installation and Custom ization 16 Cable management options for 600-mm and 750-mm enclosur es Product SKU Description Figure 19-inch horizontal cable orga nizers AR8602 (1 U) AR8600 (2 U) AR8601 (2 U double sided) AR8603A (2 U high density) Route patch cables horizontally at the front or rear of a 19-inch EIA enclosure.
17 NetShelter CX Enclosure: Installation and Cu stomization Zero-U accessory mounting bracket AR771 1 The bracket can be mounted i n various locations through out the enclosure for supporting small accessories and equipment.
NetShelter CX Enclosure: Installation and Custom ization 18 1-U cable ring AR7707 Fastens cables to posts, for use with 750-mm enclosure networking applications. T oolless Hook-and- Loop Cable Manage rs AR8621 A toolless mount hook-and-loop cable fastener for org anizing dat a cable bundles.
19 NetShelter CX Enclosure: Installation and Cu stomization Cooling Enclosure placement When placing the NetShelter CX in an open office environment: • The rear of the unit can be pushed fully against a wall. Six to eight inches of clearance should be left on either side of the unit.
NetShelter CX Enclosure: Installation and Custom ization 20 S pecifications 750-mm, 18, 24, 38-U Enclosures Item Measurements AR4018A AR4018IA AR4024A AR4024IA AR4038A AR4038IA Height 1050 mm (41 in) 1290 mm (51 in) 1950 mm (77 in) W idth 750 mm (30 in) 750 mm (30 in) 750 mm (30 in) Depth 1 130 mm (44.
21 NetShelter CX Enclosure: Installation and Cu stomization T wo-Y ear Factory W arranty This warranty applies only to the products you purchase for your use in accordance with this manual. T erms of warranty APC warrants its products to be free from defects in materials and workmanship for a period of two years from the date of purchase.
NetShelter CX Enclosure: Installation and Custom ization 22 IN NO EVENT SHALL APC, ITS OFFICERS, DIRECTORS, AFFILIA TES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT , SPECIAL, CONSEQUENTIAL OR PUNI.
.
08/2012 990-3594A-00 1 APC W orldwide Customer Support Customer support for this or any other APC product is available at no char ge in any of the follow ing ways: • V isit the APC W e b site to acce ss documents in the APC Knowledg e Base and to submit customer support requests.
Een belangrijk punt na aankoop van elk apparaat APC AR4038A (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen APC AR4038A heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens APC AR4038A vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding APC AR4038A leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over APC AR4038A krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van APC AR4038A bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de APC AR4038A kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met APC AR4038A . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.