Quick Reference MGE™ Galaxy™ 3500 Series 10-40 kV A 380/400/ 415 V 3:3 15-40 kV A 380/400/415 V 3:1.
.
Content s MGE Gala xy 3500 10 -40 kVA 3 80/400/415 V Quick Re ference i Product Overview...... ................ ............... ................ ....... 1 UPS for up to 2 b attery modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 UPS for up to 4 b attery modules .
MGE Gala xy 3500 10 -40 kVA 3 80/400/415 V Quick Re ference ii Batteries ........... ......... ................ ............... ............. ......... 11 Specific ations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
MGE Gala xy 3500 10 -40 kVA 3 80/400/415 V Quick Re ference iii Cables ................ ............ .......... ......... ............ .......... ........ 22 Recommende d Cable Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 380 V, 40 0 V, and 415 V .
MGE Gala xy 3500 10 -40 kVA 3 80/400/415 V Quick Re ference iv Empty Cabinet for Transformer - floor-mount . . . . . . . . . . . . . . . . . 31 Parallel Capabil ities.............. ................ ............ .......... ... 32 Communication cable s .
1 MGE Ga laxy 3500 10-40 kVA 380/400/4 15 V Quick Reference Product Overview The MGE Galaxy 3 500 UPS is availabl e in the f ollowing models : UPS for up to 2 b attery modu les • MGE Galaxy 3500 10 .
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 2 Serviceability • Batter ies that can be r eplaced by quali fied per sonnel: Increa ses avail ability by allowing qualif ied personne l t.
3 MGE Ga laxy 3500 10-40 kVA 380/400/4 15 V Quick Reference Default Settings System settings (only updated when in load disconnect) Default s ettin g Nominal output vol tage (ph-p h) 380/400 /415 V Fr.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 4 AC Input S pecifications 380 V , 400 V , and 415 V 380 V , 400 V , and 415 V 3:1 Input Power Fac t or 10 kV A 15 kV A 20 kV A 30 kV A 40 k.
5 MGE Ga laxy 3500 10-40 kVA 380/400/4 15 V Quick Reference AC Outpu t S pecifications 380 V , 400 V , and 415 V 380 V , 400 V , and 415 V 3:1 10 kV A 15 kV A 20 kV A 30 kV A 40 kV A 380 V 400 V 415 V.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 6 Efficiency Note: The bel ow figures are for t he 3:3 version on ly . Note: Low line is 348 V and high line is 452 V (+/- 13%). Efficiency Curves System 25% load 50% load 75% load 100% loa d 10 kV A 400 V 91.
7 MGE Ga laxy 3500 10-40 kVA 380/400/4 15 V Quick Reference 80, 0 82, 0 84, 0 86, 0 88, 0 90, 0 92, 0 94, 0 96, 0 98, 0 02 0 4 0 6 0 8 0 1 0 0 Load [% ] E ffi c i en cy [% ] Low li ne v ol t age N omi.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 8 Derating due to Load Power Fac tor 0.25 kW C o s f = 0 . 8 C o s f = 0 . 7 C o s f =0 . 6 C o s f = 0 . 5 C o s f = 0 . 8 C o s f = 0 . 7 C o s f = 0 . 6 C o s f = 0 . 5 kVAr -0.2 0.50 0.75 1.
9 MGE Ga laxy 3500 10-40 kVA 380/400/4 15 V Quick Reference Environment al General T emperatur e • Operating 0-40º C • Sto rage with batteries -15-45º C • Sto rage without batter ies -30-70º .
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 10 Heat Dissip ation 380 V , 400 V , and 415 V 380 V , 400 V , and 415 V 3:1 10 kV A 15 kV A 20 kV A 30 kV A 40 kV A Batt eries fully ch arg.
11 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference Batteries S pecifications Efficiency DC t o AC 380 V , 400 V , and 415 V 380 V , 400 V , and 415 V 3:1 10-40 kV A 380/400/ 415 V Ty p e V R L A Nominal voltage (VDC) +/- 192 Float vo ltage (VD C) +/- 219 End o f discharge v oltage (V DC) +/- 154 Batter y curre nt (a t full l o ad) 87.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 12 Battery Run-Times (Mi nutes ) - A PC Bat tery Solution Note: “# of battery shelves ” indicat es the total number of populated bat t ery shelv es in the UPS and Batt ery Enclosure.
13 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference 15 kV A 400 V typical performances Load kV A # of battery shelves 1369 1 2 1 5 1 n .a. n.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 14 20 kV A 400 V typical performances Load kV A # of battery shelves 2 4 8 1 21 62 0 1 n .a.
15 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference 30 kV A 400 V typical performances Load kV A # of battery shelves 2 6 12 18 24 30 1 n .a.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 16 40 kV A 400 V typical performances Load kV A # of battery shelves 4 8 16 24 32 40 1 n .a.
17 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference Battery Run- Times - Non-Modula r Batter ies • The be low battery r un-times are bas ed on high qu ality batter ies from ap proved manuf.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 18 20 kV A 30 kV A 40 kV A Battery Ah Load % 20 hr rate Ah Approx. equivalent 10 hr rate Ah 40 50 60 70 8 0 90 10 0 15 14 26 19 15 12 10 8 7.
19 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference Battery Disch arge Curre nt 380 V , 400 V , and 415 V End of Dischar ge V olt age 10 kV A 15 kV A 20 kV A 30 kV A 40 kV A I b at @ V bat nominal , 100% loa d 22 33 44 66 88 I b at @ V bat min, 100% load 28 41 55 83 110 I b at @ V bat min, 150% lo ad 40 62 83 125 166 1.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 20 AC Byp ass S pecifications 380 V , 400 V , and 415 V 380 V , 400 V , and 415 V 3:1 10 kV A 15 kV A 20 kV A 30 kV A 40 kV A 380 V 400 V 41.
21 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference Physical Dimensions W eight s 380 V , 400 V , and 415 V 380 V , 400 V , and 415 V 3:1 XR battery en closure w eights * The tot al weight of the X R batte r y enclosu re includin g the separ ate batt ery packa ge.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 22 Cables Recommended Cable Sizes Note: Refer to IEC 6 0364-5-52 f or instal lation meth ods. The re commended cable sizes are f or insta llation me thod B2 and ba sed on an en vironment with an a mbient tempe rature of 30° C.
23 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference Fuses and Breakers Single utility/ma ins syste m Dual utility /mains syste m Q1: Utility input Q3: Manual Bypass Q2: UPS output MBS: Mecha.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 24 Parallel Sy stem Fuse and Br eaker Sizes 380 V , 400 V , and 415 V 380 V , 400 V , and 415 V 3:1 Q1: Utility input Q4: System output Q2: .
25 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference 380 V , 400 V , and 415 V Parallel system with up to three UPS unit s Note: It is not possible to ru n the 3:1 version in parallel. Q3 and Q 4 in capacity sys tems . Q3 and Q4 in re dundant systems ( n +1).
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 26 Minimum Breaker Settings 380 V , 400 V , and 415 V 380 V , 400 V , and 415 V 3:1 Duration 800% ov erload bypass operatio n 150% over l oad normal/battery operation 125% overload normal/battery operation Contin uously 500 ms 60 s 10 min.
27 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference Communication and Management Network Man agement Card The syste m is equipped with one network manage ment card f or remote m onitor ing and cont rol of a n indivi dual UPS by con necting it direct ly to the network.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 28 Input and Output Cont act s Pin connections J106 (U PS) Pin connect ions J106 (UPS) 8) Exernal char ging control return 7) External con trol of char ging 6) Q3 active return 5) Q3 active 4) Battery measuremen t s upply* 3) Battery unit quantity* 2) Max.
29 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference EPO Pin connections J108 Pin connecti ons J108 1) Norma lly open EPO 2) Norma lly open EPO ret urn 3) Norma lly closed EPO 4) Norma lly cl.
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 30 Compliance Regulatory Approvals Directives fo r CE m arking 89/336/ EDC 73/237/ EEC Safety EN/IE C62040-1-1 UL1778 EMC EN50091 -2/IEC62 0.
31 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference Options Parallel MBP - wall-mount • For a li ne-up-and-match solution with up to t hree UPS uni ts in parallel • T wo versi ons for 1 .
MGE Gala xy 3500 10 -40 kVA 380/4 00/415 V Quick Re ference 32 Parallel Cap abilities Up to four UPS units ca n be connec ted in parallel vi a the Parallel Communi cation Ki t. Communication c ables Schematic of the PBus cab les layout Note: If the conf igurati on consists o f only two UPSs, the t erminator s must be i nstalled in UPS 2.
33 MGE Galax y 3500 10-4 0 kVA 38 0/400/415 V Quick Reference Overview of Po wer Connections The below d iagrams shows a p arallel sy stem with three UPS u nits and XR Battery Enclosure s .
10/2009 990-3661-001 *990-3661-001* APC W orldwide Customer Support Customer s upport for this or any oth er APC product i s availab le at no c harg e in any of the following ways : • V isit th e APC W eb site to access docume nts in t he APC Knowledge Ba se and to submit cu stomer support requests.
Een belangrijk punt na aankoop van elk apparaat APC G35T30KH3B4S (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen APC G35T30KH3B4S heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens APC G35T30KH3B4S vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding APC G35T30KH3B4S leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over APC G35T30KH3B4S krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van APC G35T30KH3B4S bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de APC G35T30KH3B4S kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met APC G35T30KH3B4S . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.