Report No.116-L-49-5 I N S T A L L A T I O N A N D O P E R A T I O N I N S T R U C T I O N S V ent-Free Millivolt Dual-Listed Gas Log Sets Shadowdance™ Series P/N 85005 1M R ev .
2 IM PO R T A NT S AFE TY A ND W AR NI NG IN FO RM A T IO N REA D TH IS M ANUA L IN ITS ENTI RETY AND UNDE R- ST AN D TH ESE RULES TO FOLL OW F OR SA FETY .
3 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. These Gas Log Appliances incorporate unitized ceramic fiber logs which provides some glow realistically when the appliance is operating. The gas log sets covered in this document are heater rated units.
4 Adhere to all local codes or in their absence the latest edition of The National Fuel Gas Code ANSI Z223.1 or NFPA 54-latest edition which can be obtained from The American National Standards Institute, Inc. (1430 Broadway , New Y ork, NY , 10018) or National Fire Protection Association, Inc.
5 This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and venti lation air.
6 Not e: Illustrations shown in this manual reflect “typical” installations with nominal dimensions and are for reference only . Actual installations may vary due to individual design preferences. However , always main- tain minimum clearances to combustible materials and do not violate any specific installation requirements.
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 7 Figure 3 Step 2. Ceiling Clearance: The ceiling must be at least 42" from the top of the appliance opening ( Figure 2 ) .
8 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. Any outside air ducts and/or ash dumps in the fireplace shall be perma- nently closed at time of appliance installation. A qualified gas appliance installer must install this dual-listed appli - ance.
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 9 The appliance gas inlet connection is 3/8" NPT at the regulator/valve, located on the left side facing the appliance. If a right side connection is requ ired, the conn ection pip e may be pipe d under the rear of the appli ance to end at the left hand side for connection to the inlet.
10 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. LOG PLACEMENT INSTRUCTIONS 1. Place rear ember bed as shown in Figure 11 . Figure 11 - Install Rear Ember Bed 2. Place rear log onto the two rear grate locating pins as shown in Figure 12 (the locating pins are outlined in Figure 11 ).
11 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 7. Place the right top log onto rear log locating pin and the right front log locating pin as shown in Figure 17 . Right T op Log Locating Pins 8. Pla ce Lef t T op T wig (24 " and 30" mod els only ) ont o cor resp ondin g notch on rear log as shown in Figure 18A .
12 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. T op Burner Air Shutter Adjustment Procedure 1. If you ha ve blue flame or the top bur ner is no t carry ing ove r and bu rning on all ports , the air shutter may need to be adjusted to 1/8 " gap for bot h Natu ral a nd Pro pane gas.
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 13 1. Appliance operation may be controlled through the ON/OFF unit rocker switch, located in the bottom front of the appliance or through an optional remote control . 2. When lit for the first time, the appliance will emit an odor for an hour or two.
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 14 (ref form #750127M) (ref form #750129M) Standard Remote Control System (Model RCL) The Model RCL (Standard) Remote Control System, features a simplistic on/off control function for the fireplace.
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 15 (ref form #750252M) (ref form #750010M) ACCESSORY COMPONENTS (CONTINUED) * Fo r use with g as tra in mode ls LSV FSD-NG and L SVFSD-L P only 18" Gas Log Set 24" Gas Log Set Charred Ember Kit* Cat.
NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. 16 * For the purpose of input adjustment. PILOT (O.D.S.) ASSEMBLY THERMOPILE WHITE WHITE WHITE RED MILLIVOL T VAL VE ON/OFF SWITCH PILOT PIEZO IGNITER IGNITION WIRE OFF ON OPTIONAL REMOTE CONTROL (MILLIVOL T) Vented/Unvented Gas Log Appliance T echnical Chart For Millivolt Log Set Model No.
17 4. Depress gas control knob slightly and turn clockwise to “OFF .” Do not for ce. 5. Close lower control compartment. LIGHTING INSTRUCTIONS – MILLIVOL T WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTL Y , A FIRE OR EXPLOSION MA Y RESUL T CAUSING PROPERTY DAMAGE, PERSONAL INJUR Y OR LOSS OF LIFE.
18 VENTED/UNVENTED TROUBLESHOOTING GUIDE OBSERVED PROBLEM POSSIBLE CAUSE REMEDY 1. When igniter button is pressed, there is no spark at ODS/pilot. A. Igniter electrode positioned wrong. Replace igniter . B. Igniter electrode broken. Replace igniter . C.
19 NOTE: DIAGRAMS AND ILLUSTRA TIONS ARE NOT TO SCALE. REPLACEMENT P ARTS LIST (MILLIVOL T) - SHADOWDANCE™ SERIES Replacement Parts List (Millivolt) - Shadowdance™ Series, Models LSVFSD-NG and LSVFSD-LP (18" and 24") No. Description Catalog Number 1.
20 Lennox Hearth Products reserves the right to make changes at any time, without notice, in design, materials, specifications, prices and also to discontinue colors, styles and products. Consult your local distributor for fireplace code information.
Een belangrijk punt na aankoop van elk apparaat Lennox Hearth LSVFSD-18 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lennox Hearth LSVFSD-18 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lennox Hearth LSVFSD-18 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lennox Hearth LSVFSD-18 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lennox Hearth LSVFSD-18 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lennox Hearth LSVFSD-18 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lennox Hearth LSVFSD-18 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lennox Hearth LSVFSD-18 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.