Page 1 02/13 *2P0213* 507067-01 *P507067-01* E 2013 Lennox Industries Inc. Dallas, T exas, USA AIR FLOW UPFLOW AIR FLOW AIR FLOW HORIZONT AL RIGHT HORIZONT AL LEFT INST ALLA TION INSTRUCTIONS EL296UHE.
Page 2 EL296UHE Unit Dimensions - inches (mm) 1−1/ 2 (38) 9/16 (14 ) AIR FLOW mm in. 6−9/16 (167) Left 9 (229) Right 23 (584) (19) 3/4 (19) 1 Bottom Return Air Opening GAS PIPING INLET (Either Sid.
P age 3 EL296UHE Gas Furnace The E L296UHE Category IV gas furnace is s hipped ready for installation in the upflow o r h orizontal position. T he f ur nace is shipped with the bottom panel in place. The bot tom panel must b e removed i f the unit is to b e installed in horizontal or upflow applications with bottom return air .
Page 4 In order to ensure proper unit operation in non-direct vent applications, combustion and ventilation air supply must be provided according to the current National Fuel Gas Code or CSA‐B149 standard.
P age 5 D The input rate and temperature rise must be set per the furnace rating plate. D One hundred percent (100%) outdoor air must be pro vided for combustion air requirements during construc tion. T emporary ducting may supply outdoor air to the furnace.
Page 6 piping. A portion of this information has been reprinted with permission from the National F uel Gas Code ( ANSI- Z223.1/NFP A 54). This reprinted material is not the com plete and official position of the ANSI on the referenced subject, w hich is represented only by the standard in its entirety .
P age 7 Air from Outside If a ir f r om o utside i s b rought i n for combustion and v entila tion, t he confined space shall be provided with two perma nent o penings. One opening s hall be within 1 2” (305mm) of t he t op o f the enclosure and one within 12” ( 305mm) o f the bottom.
Page 8 FIGURE 9 EQUIPMENT IN CONFINED SP ACE - ALL AIR FROM OUTSIDE OUTLET AIR INLET AIR NOTE -Each air duct opening shall have a free area of at least one square inch per 2,000 Btu (645mm 2 p er .59kW) per hour of the total input rating of all equipment in the enclosure.
P age 9 FIGURE 1 1 SETTING EQUIPMENT UPFLOW APPLICA TION HORIZONT AL APPLICA TION FRONT VIEW SIDE VIEW FRONT VIEW END VIEW UNIT FRONT AIR FLOW UNIT FRONT 1/2” max. 1/2” max. AIR FLOW AIR FLOW SIDE VIEW UNIT FRONT Unit must be level side-to-side. Unit may be positioned from level to 1/2” toward the front to aid in draining.
Page 10 W ARNING Improper installation of the furnace can result in per sonal injury or death. Combustion and flue products mus t never be allowed to enter the return air system or air in th e living space. Use sheet metal screws and joint tape to seal return air system to furnace.
P age 11 FIGURE 14 Optional Return Air Base (Upflow Applications Only) NOTE- Optional side return air filter kits are not for use with return air base. 1 Both the unit return air opening and the base return air opening must be covered by a single plenum or IAQ cabinet.
Page 12 The EL296UHE furnace can be installed in horizontal ap plications with either right- or left-hand air discharge. Refer to fig ure 17 for clearances in horizontal applications.
P age 13 *Gas connector may be used for Canadian installation if accept able by local authority having jurisdiction. FIGURE 19 *GAS CONNECTION RAISED PLA TFORM SERVICE PLA TFORM INT AKE PIPE EXHAUS.
Page 14 CAUTION Solvent cements for plastic pipe are flammable liq uids and should be kept away from all sources of ignition. Do not use excessive amounts of solvent ce me nt when making joints. Good ventilation should be maintained to reduce fire hazard and to minimize breathing of solvent vapors.
P age 15 8 - After assembly , w ipe e xcess c ement f rom pipe a t e nd of fitting socket. A properly made joint will show a bead a round its entire perimeter . A ny gaps may i ndi cate an improper assembly due to insuf ficient sol vent. 9 - Handle joints carefully until completely set.
Page 16 Resize the common venting system to the minimum vent pipe size determined by using the appropriate tables in Appendix G. (These are in the current stan dards of the National Fuel Gas Code ANSI Z223.
P age 17 Us e the following steps to correctly size vent pipe diameter . FIGURE 23 Piping Size Process 1 2 3 4 5 6 Which style termination being used? Standard or concentric? See table 4. Which needs most elbows? Intake or exhaust? How many elbows? Count all elbows inside and outside house.
Page 18 T ABLE 4 OUTDOOR TERMINA TION USAGE Input Size V ent Pipe Dia. in. ST ANDARD CONCENTRIC FlushMount Kit W all Kit W all Ring Kit Field Fabricated 1-1/2 inch 2 inch 3 inch 2 inch 3 inch 2 inch 5.
P age 19 T ABLE 5 Maximum Allowable Intake or Exhaust V ent Length in Feet NOTE - Size i ntake and e xhaus t pipe l ength separately . V alues in t able are for I ntake OR E xhaust, not c ombined total. Both I n tak e and E xhaus t must b e same p ipe size.
Page 20 T ABLE 5 Continued Maximum Allowable Intake or Exhaust V ent Length in Feet Size intake and exhaust pipe length separately . Values in table are for Intake OR Exhaust, not combined total.
P age 21 T ABLE 6 Maximum Allowable Exhaust V ent Lengths With Furnace Installed in a Closet or Basement Using V entilated Attic or Crawl Space For Intake Air in Feet NOTE - Size i ntake and e xhaus t pipe l ength separately . V alues in t able are for I ntake OR E xhaust, not c ombined total.
Page 22 FIGURE 24 TYPICAL EXHAUST AND INT AKE PIPE CONNECTIONS IN UPFLOW DIRECT OR NON-DIRECT VENT APPLICA TIONS TRANSITION 2” 2” 2” 3” 2” 2” or DO NOT transition from smaller to larger pipe in horizontal runs of exhaust pipe . EXHAUST *2” * When transitioning up in pipe size, use the shortest length of 2” PVC pipe possible.
P age 23 Intake Piping The EL296UHE furnace may be installed in either direct vent or non-direct vent applications. In non-direct vent applications, w hen i ntake a ir will be d rawn i n to t he f urn.
Page 24 CAUTION If this unit is being installed in an application with combustion air coming in from a space serviced by an exhaust fan, power exhaust fan, or other device which may create a negative pressure in the space, take care when sizing the inlet air opening.
P age 25 T ABLE 7 Maximum Allowable Exhaust V ent Pipe Length Without Insulation In Unconditioned Space For Winter Design T emperatures Winter Design T emperatures 1 °F (°C) V ent Pipe Diameter Unit Input Size 045 070 090 11 0 135 32 to 21 (0 to -6) 2 in.
Page 26 FIGURE 30 VENT TERMINA TION CLEARANCES FOR NON-DIRECT VENT INST ALLA TIONS IN THE US AND CANADA K D E L B C F G A B J A M I H INSIDE CORNER DET AIL VENT TERMINAL AIR SUPPL Y INLET AREA WHERE T.
P age 27 FIGURE 31 VENT TERMINA TION CLEARANCES FOR DIRECT VENT INST ALLA TIONS IN THE US AND CANADA K D E L B C F G A B J A M I H INSIDE CORNER DET AIL VENT TERMINAL AIR SUPPL Y INLET AREA WHERE TERM.
Page 28 Details of Intake and Exhaust Piping T erminations for Direct V ent Installations NOTE - In Direct V ent i nstallations, c ombustion air is t ak en from outdoors and flue gases are discharged to out doors. NOTE - Flue gas may be slightly acidic and may adversely affect some building materials.
P age 29 7 - If i ntake and exhaust piping m ust b e r un u p a s ide w all to position above snow accumulation or other ob structions, piping must be supported every 24” (610MM) as shown in figures 36 and 37 . In addition, close c oupled wall termination kits m ust be extended for use in this application.
Page 30 FIGURE 36 FIELD F ABRICA TED W ALL TERMINA TION OR (15F74) W ALL RING TERMINA TION KIT See venting table 5 for maximum venting lengths with this arrangement. * Use wall support every 24” (610MM). Use two wall supports if extension is greater than 24” (610MM) but less than 48” (1219 MM).
P age 31 FIGURE 38 2” EXTENSION FOR 2” PVC PIPE1” EXTENSION FOR 3” PVC PIPE 1-1/2” ACCELERA TOR ( all -45, -070 and -090 units) FURNACE EXHAUST PIPE FURNACE INT AKE PIPE 4'' GLUE E.
Page 32 FIGURE 44 12” (305MM) Minimum Above Grade or Average Snow Accumulation 1/2” (13 mm) FOAM INSULA TION (Field−Furnished) 5” (127 mm) 5−1/2” (140 mm) EXHAUST AIR INT AKE AIR GRADE 12” (305 mm) INT AKE AIR EXHAUST AIR GRADE 12” (305MM) Max.
P age 33 EL296UHE DIRECT VENT APPLICA TION USING EXISTING CHIMNEY NOTE - Do not discharge exhaust gases directly into any chimney or vent stack. If ver tical discharge through an existing unused chimney or stack is required, insert piping inside chimney until the pipe open end is above top of chimney and terminate as illus trated.
Page 34 NOTE - Do not discharge exhaust gases directly into any chimney or vent stack. If ver tical discharge through an existing unused chimney or stack is required, insert piping inside chimney until the pipe open end is above top of chimney and terminate as illus trated.
P age 35 FIGURE 52 T ubing Hose Clamp Barbed Fitting Field Provided Drain Components Elbow CAUTION Do not use copper tubing or existing copper conden sate lines for drain line. 6 - If unit will be started immediately upon completion of installation, prime trap per procedure outlined in Unit Start-Up section.
Page 36 FIGURE 56 EL296UHE with Evaporator Coil Using a Separate Drain (Unit shown in horizontal left-hand discharge position) . 5’ max. PVC Pipe Only 4”min 5”max Evaporator Coil Drain Pan Condensate Drain Connection Field Provided V ent (4” min.
P age 37 FIGURE 59 Drain T rap Assembly (Furnished) V ent Drain T rap Clean Out 5 Feet Maximum Coupling 3/4 inch slip X slip (Not Furnished) 90 ° Elbow 3/4 inch PVC (Not Furnished) 3/4 inch PVC Pipe .
Page 38 Gas Piping Gas s upply p iping s hould n ot a llow m ore t han 0 .5”W .C. d rop in pressure between gas meter and unit. Supply gas pipe must not be smaller than unit gas connection.
P age 39 GROUND JOINT UNION FIELD PROVIDED AND INST ALLED Left Side Piping (Standard) DRIP LEG MANUAL MAIN SHUT-OFF VA LV E Right Side Piping (Alternate) NOTE - BLACK IRON PIPE ONL Y TO BE ROUTED INSI.
Page 40 T ABLE 10 GAS PIPE CAP ACITY - FT 3 /HR (kL/HR) Nominal Iron Pipe Size inches (mm) Internal Diameter inches (mm) Length of Pipe - feet (m) 10 (3.048) 20 (6.096) 30 (9.144) 40 (12.192) 50 (15.240) 60 (18.288) 70 (21.336) 80 (24.384) 90 (27.432) 100 (30.
P age 41 Accessory T erminals One line voltage “ACC” 1/4” spade terminal is provided on the furnace integrated control. See figure 6 5 for integrated control configuration.
Page 42 TYPICAL EL296UHE WIRING DIAGRAM FIGURE 64.
P age 43 Integrated Control FIGURE 65 THERMOST A T CONNECTIONS (TB1) 1/4” QUICK CONNECT TERMINALS DS = DEHUMIDIFICA TION SIGNAL W2 = HEA T DEMAND FROM 2ND ST AGE T/ST A T W1 = HEA T DEMAND FROM 1ST .
Page 44 Integrated Control DIP Switch Settings EL296UHE units are equipped with a two-stage integrated control. This control manages ignition timing, heating mode fan off delays and indoor blower speeds based on selections made using the control dip switches and jump ers.
P age 45 T ABLE 14 EL296 Field Wiring Applications With Conventional Thermostat Thermostat DIP Switch Settings and On-Board Links (See figure 65) Wiring Connections DIP Switch 1 Thermostat Heating Stages On Board Links Must Be Cut T o Select System Options 1 Heat / 1 Cool NOT E - Use DIP switch 2 to set second-stage heat ON delay .
Page 46 T ABLE 14 EL296 Field Wiring Applications With Conventional Thermostat (Continued) Thermostat DIP Switch Settings and On-Board Links (See figure 65) Wiring Connections DIP Switch 1 Thermostat .
P age 47 T ABLE 14 EL296 Field Wiring Applications With Conventional Thermostat (Continued) Thermostat DIP Switch Settings and On-Board Links (figure 65) Wiring Connections DIP Switch 1 Thermostat Hea.
Page 48 T ABLE 14 EL296 Field Wiring Applications With Conventional Thermostat (Continued) Thermostat DIP Switch Settings and On-Board Links (figure 65) Wiring Connections DIP Switch 1 Thermostat Heat.
P age 49 Unit Start-Up FOR YOUR SAFETY READ BEFORE OPERA TING W ARNING Do not use this furnace if any part has been under water . A flood-damaged furnace is extremely dan gerous.
Page 50 4 - Move gas valve switch to OFF . 5 - Replace the access panel. Failure T o Operate If the unit fails to operate, check the following: 1 - Is the thermostat calling for heat? 2 - Are access p.
P age 51 Proper Combustion Furnace should operate minimum 15 minutes with correct manifold pressure and gas flow rate before checking com bustion. T ake combustion sample beyond the flue outlet and compare to the tables below . T ABLE 16 EL296 Model CO 2 % For Nat CO 2 % For L.
Page 52 T esting for Proper V enting and Sufficient Combustion Air for Non-Direct V ent Applications W ARNING CARBON MONOXIDE POISONING HAZARD! Failure to follow the steps outlined below for each appliance connected to the venting system being placed into operation could result in carbon monox ide poisoning or death.
P age 53 Other Unit Adjustments Primary Limit . The primary limit is located on the heating compartment vestibule panel. This limit is factory set and requires no ad justment. Flame Rollout Switches (T wo) These manually reset switches are located on the front of the burner box.
Page 54 Applications Using A Single-Stage Thermostat B - Heating Sequence -- Integrated Control Thermostat Selection DIP Switch 1 ON in “Single-Stage” Position NOTE - In these applications, two-st.
P age 55 Service W ARNING ELECTRICAL SHOCK, FIRE, OR EXPLOSION HAZARD. Failure to follow safety warnings exactly could result in dangerous operation, serious injury , death or property damage. Improper servicing could result in dangerous opera tion, serious injury , death, or property damage.
Page 56 Start-Up & Performance Check List Gas Supply Pressure SUPPL Y AIR Line V oltage GAS SUPPL Y Natural Gas LP Propane Gas Piping Connections Tight Leak T ested Supply Line Pressure “W .
P age 57 Contractor's: Name_________________________T elephone_____________Checklist Completed____________________ Job Address_____-________________________________T echnician's Name___________________________________ 1 HEA TING MODE GAS MANIFOLD PRESSURE “W .
Page 58 Requirements for Commonwealth of Massachusetts Modifications to NFP A-54, Chapter 10 Revise NF P A-54 section 10.8.3 to add the following re quirements: Fo r all side wall, horizontally ven.
Een belangrijk punt na aankoop van elk apparaat Lennox International Inc. EL296UHE (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lennox International Inc. EL296UHE heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lennox International Inc. EL296UHE vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lennox International Inc. EL296UHE leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lennox International Inc. EL296UHE krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lennox International Inc. EL296UHE bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lennox International Inc. EL296UHE kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lennox International Inc. EL296UHE . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.