7/2012 506945-01 *2P72012* *P506945-01* Page 1 E 2013 Lennox Industries Inc. Dallas, T exas, USA THIS MANUAL MUST BE LEFT WITH THE HOMEOWNER FOR FUTURE REFERENCE W ARNING The State of California has determined that this product may contain or produce a chemical or chemicals, in very low doses, which may cause serious illness or death.
Page 2 A B SIDE VIEW UNIT DIMENSIONS - INCHES (MM) FIGURE 2 T ABLE 1 UNIT DIMENSIONS Model Numbers A B 13ACX-018-230 24-1/4 (616) 25-1/4 (641) 13ACX-024-230 24-1/4 (616) 25-1/4 (641) 13ACX-030-230 24-.
Page 3 13ACX SERIES ANCHORED HEA VY NYLON WIRE TIE OR AUT OMOTIVE MUFFLER‐TYPE HANGER STRAP LIQUID LINE TO V APOR LINE W ALL STUD LIQUID LINE NON-CORROSIVE MET AL SLEEVE V APOR LINE - WRAPPED IN ARM.
Page 4 STEP 2 -- REFRIGERANT PIPING -- Flushing Existing Line Set and Indoor Coil Flush the existing line set per the following instructions. For more information, refer to the Installation and Service Procedures manual available on DaveNet.
Page 5 13ACX SERIES STEP 2 -- REFRIGERANT PIPING -- Removing Existing Indoor Metering Device SENSING LINE TEFLON ® RING FIXED ORIFICE BRASS NUT LIQUID LINE ASSEMBL Y (INCLUDES STRAINER) LIQUID LINE O.
Page 6 STEP 2 -- REFRIGERANT PIPING -- Brazing Procedures A TT ACH THE MANIFOLD GAUGE SET FOR BRAZING LIQUID AND SUCTION / V APOR LINE SERVICE V AL VES OUTDOOR UNIT LIQUID LINE V APOR LINE LIQUID LINE.
Page 7 13ACX SERIES WHEN BRAZING LINE SET TO SER VICE V AL VES, POINT FLAME A WA Y FROM SER VICE V AL V E. LIQUID LINE SERVICE V AL VE LIQUID LINE BRAZE LINE SET Wra p both service valves with water -saturated cloths as illustrated here and as mentioned in step 4, before brazing to line set.
Page 8 STEP 2 -- REFRIGERANT PIPING -- Installing Indoor Expansion V alve This outdoor unit is designed for use in systems that use either an fixed orifice (RFC) (included with outdoor unit), or expansion valve metering device (purchased separately) at the indoor coil.
Page 9 13ACX SERIES STEP 3 -- LEAK TEST AND EV ACUA TION A With both manifold valves closed, connect the cylinder of HFC-410A refrigerant to the center port of the manifold gauge set. Open the valve on the HFC-410A cylinder (vapor only). B Open the high pressure side of the manifold to allow HFC-410A into the line set and indoor unit.
Page 10 STEP 3 -- LEAK TEST AND EV ACUA TION (CONTINUED) A Open both manifold valves and start the vacuum pum p. B Evacuate the line set and indoor unit to an absolute pressure of 23,000 microns (29.01 inches of mercury). NOTE — During the early stages of evacuation, it is desirable to close the manifold gauge valve at least once.
Page 1 1 13ACX SERIES STEP 4 -- ELECTRICAL -- Circuit Sizing and Wire Routing In t he U .S .A., w iring must conform with current local codes a nd the current National Electric Code (NEC). In Canada, wiring must conform with cur rent local codes and the current Canadian Elec trical Code (CEC ).
Page 12 STEP 4 -- ELECTRICAL (CONTINUED) -- High V oltage and Field Control Wiring The following illustration provide an example of control wiring connections when using standard thermostat. Any excess high voltage field wiring should be trimmed and secured away from any low voltage field wiring.
Page 13 13ACX SERIES T ABL E 3 . T O RQUE REQUIREM ENTS Parts Recommended Torque Service valve cap 8 ft.- lb. 1 1 NM Sheet metal screws 16 in.- lb. 2 NM Machine screws #10 28 in.- lb. 3 NM Compressor bolts 90 in.- lb. 10 NM Gauge port seal cap 8 ft.- lb.
Page 14 CHECKING AND ADDING SYSTEM REFRIGERANT The 13ACX unit is factory-charged with enough HFC-410A refrigerant to accommodate a 15-foot length of refrigerant piping. Charge should be checked and adjusted using the tables provided on the charging procedure sticker located o n th e unit access panel.
Page 15 13ACX SERIES 13ACX Start-Up and Performance Checklist Customer Address Indoor Unit Model Serial Outdoor Unit Model Serial Notes: ST ART UP CHECKS Refrigerant T ype: Rated Load Amps: Actual Amp.
Een belangrijk punt na aankoop van elk apparaat Lennox International Inc. Merit Series Air Conditioner (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lennox International Inc. Merit Series Air Conditioner heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lennox International Inc. Merit Series Air Conditioner vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lennox International Inc. Merit Series Air Conditioner leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lennox International Inc. Merit Series Air Conditioner krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lennox International Inc. Merit Series Air Conditioner bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lennox International Inc. Merit Series Air Conditioner kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lennox International Inc. Merit Series Air Conditioner . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.