Gebruiksaanwijzing /service van het product Smart-UPS 2200VA van de fabrikant APC
Ga naar pagina of 16
990-1352A 11/2003 User Manual English APC Smart-UPS ® 2200 VA 120/230 Vac 3000 VA 100/120/208/230 Vac 2U Rack Mount Uninterruptible Power Supply.
.
1 Introduction The APC Uninterruptible Power Supply (UPS) is de signed to prev ent blackouts, brownou ts, sags, and surges from reaching y our eq uipment. The uninterruptible powe r supply (UPS) filters small util- ity line fluct uations and i solates yo ur equipm ent from l arge disturbances by inter nally disconnect ing from the utility line.
2 Mount the UPS in a Rack Your UPS m odel may vary from t he examples depi cted in thi s manual. Install brackets as shown, or at a 5 in (12.7 cm ) setback. Remove the battery m odule to li ghten the UP S during instal lation. N ote: The m odule is hea vy.
3 Connect Equipment and Power to the UPS Startup 1. Connect equi pment to the UPS. A laser printer draws signi ficantly more power t han other t ypes of equipm ent and ma y overload the UPS. 2. Add optional accessori es to t he Smart-Slot. 3. Plug the UP S into a tw o-pole, three-wire, grounded rece ptacle onl y.
4 Basic Connectors Serial Port USB Port TVSS Screw Use only interface kits approved by APC. Use only the supplied cable t o connect to the Serial Port. A standard serial interface cable is incompatible with the UPS. Serial and USB Ports cann ot be used simultaneousl y.
5 2: O PERA TION Front Display Panel I NDICATOR D ESCRIPTION Online The UPS is supplying utility power to the conn ected equipment (s ee Troubleshoot- ing ). AVR Trim The UPS is compensating for a h igh utility vol tage. AVR Boost The UPS is compensating for a low utility voltag e.
6 F EATURE F UNCTION Self-Test Automatic: The UPS perform s a self-test autom atically when turn ed on, and ever y two weeks thereafter, (by default). During the self-test, the UPS briefl y operates the connected equipment on b attery. Manual: Press and hold the button for a few seconds to initiate the self-test.
7 3: U SER C ONFIGURABLE I TEMS N OTE : S ETTINGS ARE A DJUSTED THROUGH P OW ER C HUTE SOFTWARE OR OPTIONAL S MA R T S LOT A CCESSORY CA RDS . F UNCTION F ACTO RY D EFAULT U SER S ELECTABLE C HOICES D.
8 N OTE : S ETTINGS ARE A DJUSTED THROUGH P OW ER C HUTE SOFTWARE OR OPTIONAL S MA R T S LOT A CCESSORY CA RDS . F UNCTION F ACTO RY D EFAULT U SER S ELECTABLE C HOICES D ESCRIPTION Low Battery Warn- ing 2 minutes PowerChute soft- ware provides automatic, unat- tended shutdown when approxi- mately 2 minutes of battery oper- ated runtime re- mains.
9 4: S TOR AG E , M AINTENANCE , T RANSPORTI NG , AND S ERVICE Storage Store the UP S covered i n a cool, dry loca tion, with the batteries fully charged. At -15 to +3 0 ° C (+5 to +86 ° F), charge the UPS battery every si x months. At +30 to +45 ° C (+86 to +113 ° F), charge the UPS battery every three m onths.
10 Service If the UPS requires service do not return it to the dealer. Follow these step s: 1. Review the pr oblems discussed in Tr oubleshooting to elim inate common problem s. 2. If the probl em persists, co ntact APC C ustomer Service throug h the APC web site, www.
11 5: T ROUBLESHOOTING Use the chart below to solve minor UPS installation and operation problems. Refer to www.apc.co m with complex UPS problems. P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION UPS WILL NOT TURN ON Battery not connected prop- erly. Check that the b attery connec tor is fully sn apped into position.
12 P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION THE OVERLOAD LED IS ILLUMINATED AND THE UPS EMITS A SUSTAINED ALARM TONE The UPS is over loaded. The connected equipment exceeds the “maximum load,” as de- fined in Specifications at www.apc.com . The alarm remains on unt il the overlo ad is removed.
13 P ROBLEM AND / OR P OSSIBLE C AUS E S OLUTION UPS OPERATES ON BATTERY A LTHOUGH LINE VOLTAGE EXISTS The UPS input circuit breaker tripped. Reduce the load on the UPS by unplugging equipment. Reset the breaker. Very high, low, or distorted line voltage.
14 6: R EGULA TOR Y AND W ARRANTY I NFORMA TION Regulatory Agency Approvals a nd Radio Frequency Warnings 120/208 V models 230 V models BSMI This equipm ent has been tested a nd found t o com- ply with the limits for a Class A digital device, pur- suant to part 15 of the FCC Rules.
Een belangrijk punt na aankoop van elk apparaat APC Smart-UPS 2200VA (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen APC Smart-UPS 2200VA heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens APC Smart-UPS 2200VA vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding APC Smart-UPS 2200VA leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over APC Smart-UPS 2200VA krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van APC Smart-UPS 2200VA bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de APC Smart-UPS 2200VA kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met APC Smart-UPS 2200VA . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.