Inst allation and Operatio n Smart- UPS ® SUA1000- BR/SUA1500 -BR 120 V AC Eng lish.
This manu al and th e safet y guide are avai labl e in Englis h on th e enclos ed CD and the APC W eb sit e, www .ap c.com . Este man ual e o g uia d e se guranç a est ão d isponíve is e m p ortugu ês no CD i nclus o e n o w ebsite da A PC, www .apc .
1 I ntroduct ion Th e AP C ® by Sch n ei d er Elect r i c Smar t - UPS ® is a hig h pe r fo rmance u ninterruptib le pow er supply (UP S) . It pr ovi d es pr ot e ct i on for el ect r on i c eq ui p m en t fr om ut i li t y po wer bl a ck ou t s , br own ou t s , sa g s , and surge s; smal l utility fluctuations a n d l ar ge d isturba n ces .
2 Conne cti ng Eq uipme nt and P ower to the UP S S M ART -UPS R E AR P ANEL 1. Pl ug in th e battery connector n . 2. Conn ect equ i pmen t to th e UPS. No te : D o no t con nect a las er print er to the UP S. A las er printer d raws si gnificantly m ore po wer than other typ e s of equ ipm e nt and may o verload the UPS .
3 B ASIC C ONN ECT ORS Seria l P ort USB Port Pow er man a gem en t soft war e and int er face k i t s can be used w ith t h e U PS. U se o nly in terf ac e ki ts s u pp lied o r app rov ed by APC. Us e the AP C s u pplied ca ble to con nect to th e S eria l Po rt.
4 On Ba tte ry Wh en th e on bat te r y pow e r LED is lit the UP S is supply in g b att e r y pow er t o t h e c onnected e quipme nt. Whe n o n ba ttery , the U P S so un ds an alar m— four beep s e ver y 30 secon d s.
5 3: U SER C ON FI GURAB LE I TEM S N OTE : S ETTINGS ARE M A D E THROUG H SUPPLIED P OWE R C HUTE SOFTWA RE OR OP TIONA L S MA R T S LOT A CCESS O RY CA RDS .
6 N OTE : S ET TIN G S AR E M ADE TH RO UG H SU P PLIED P OWER C HUT E SOFTWA RE OR OPTI O N A L S MA R T S LO T A CCESS O RY CA RDS . F UNC TI ON F ACTORY D EFAUL T U SER S ELE CT ABL E C HO ICE S D .
7 4: S TORA G E , M AINT E N AN C E , AND T RAN SPORTIN G Storage Sto r e t he U PS co ve red a nd p os itione d as fo r pro pe r f unc tio ning , i n a co o l, dry locatio n, w ith t he b a t- ter i es full y ch ar g ed. At - 1 5 t o + 3 0 ° C ( +5 to + 8 6 ° F ), ch ar ge th e UPS bat t ery ever y six m on th s.
8 1500VA Model Step 3 Pu ll t h e b atte r y mo dule ou t of th e co mpa rtmen t un t il th e ba ck of th e modu l e i s f l u sh with th e out er ed g es of t h e UPS .
9 R EPLACI NG THE B ATTERY M ODULE To r epla ce th e batt er y m odu l e, rever s e th e dir ect i on s above f or Remo ving the Front Be z e l and Battery Mo dule . Disconnec ting th e Batter y for Tr ansport 1. Sh ut down and d is conn ect an y eq ui p men t att a ched t o th e UPS.
10 5: T ROUBLES HOOT IN G Use t h e char t belo w to sol ve min or Smar t- UPS in s ta lla ti on an d oper at i on pr oblem s. Refer t o th e AP C We b s ite, www. a p c . c om , for a s si stan ce wi th com pl ex UPS pr oblem s. P ROBLE M AND P OSSI BL E C AU S E S OLU T ION UPS WILL NOT TURN ON Battery not co nnected prop- erly .
11 P ROBLE M AND P OSSI BL E C AU S E S OLU T ION T HE O V ERL OAD LED IS LIT A ND THE UPS EMI T S A SU S T AIN E D AL AR M TO N E Th e U PS i s ove r l oa d e d. The co nnected equi pmen t exceed s the spec ifi ed “max i mum load” as defi ned i n Spe cificat i o ns at th e APC w e b si te , www.
12 P ROBLE M AND P OSSI BL E C AU S E S OLUTI O N UTILITY CIRCUIT BREAKER TRI PS Util it y c i r cui t bre a ker trip s dur ing no r mal o pera t ion. Reduc e the load o n t he U PS by unplug ging equipmen t and rese t ting t he circ ui t b reaker (on t he bac k of UPS ) by pressing the plung er in.
13 Ser vice If the uni t req ui res se r v ice , do no t retu rn it to t he de ale r . F o llow th es e s tep s: 1. Re vi e w t h e Troubleshoo ting se c tion o f the man ual to elim ina te c ommo n pro b lems . 2. If the prob lem persists, co ntact AP C Custo mer Suppo rt throu gh the APC We b site, www.
14 6: R AD I O F REQ UENCY W AR N I NG S AND W AR R ANT Y This de v ice comp lies w ith FCC Par t 15 Clas s A r eq ui reme nt s. Op e r atio n is sub j ect to the fo llow in g tw o conditio ns: ( 1) t.
15 REME DY FOR ANY BRE ACH OF SUCH W ARRANTIES. APC WARRANTIE S RUN ONLY TO PURCHASER AND ARE NOT EXTENDED TO ANY T H IRD PARTIES. IN NO EV EN T SH AL L AP C, IT S OF F ICE RS, D I RE CT O RS, A FF IL.
12/20 09 990- 3828.
Een belangrijk punt na aankoop van elk apparaat APC SUA1000-BR (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen APC SUA1000-BR heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens APC SUA1000-BR vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding APC SUA1000-BR leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over APC SUA1000-BR krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van APC SUA1000-BR bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de APC SUA1000-BR kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met APC SUA1000-BR . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.