INSTALLATION AND OPERATION MANUAL THIS APPLIANCE MUST BE INSTALLED BY A QUALIFIED INSTALLER. READ ENTIRE MANUAL THOROUGH LY BEFORE INSTALLATION. P MODEL 1400HT P/N 775000M, Rev.
IMPORTANT WARNINGS CAUTION: PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL AND USE YOUR NEW ROOM HEATER. FOR YOUR SAFETY, FOLLOW THE INST ALLATION, OPERATION AND MAINTENANCE INSTRUC- TIONS EXACTLY, WITHOUT DEVIATION. FAILURE TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.
TABLE OF CONTENTS PAGE 3 Important Warn ings ................................................ 2 Testing/Listing, EPA, Using this Manual .................. 3 Planning Your Inst allation ..................................... 4-6 Manufactured (Mobile) Ho me Requirements .
PLANNING YOUR INSTALLATION PAGE 4 QUESTIONS TO ASK LOCAL BUILDING OFFICIAL A correct installation is critical and imperative for reduc- ing fire hazards and perilous conditions that can arise when wood burning appliances are improperly installed. The installer must follow all of the manufacturer’s in- structions.
PLANNING YOUR INSTALLATION PAGE 5 COMBUSTIBLE WALL CLEARANCE WARNING: IT IS VERY IMPORTANT THAT YOU OB- SERVE THE MINIMUM CLEARANCES. There are listed clearances for your stove which were determined in a Laboratory test using various "classes" of stove pipe or chimney.
PLANNING YOUR INSTALLATION PAGE 6 REDUCED MASONRY ST RUCTURE CLEARANCE (ALCOVE) Your Earth Stove can be installed in a masonry struc- ture with reduced clearances if the structure was built to National Building Code for fireplaces and chimneys (UBC 37).
INSTALLATION PAGE 7 MANUFACTURED (MOBILE) HOME REQUIREMENTS This stove is certified as a Room Heater, Solid Fuel Type and may be used in Manufactured Housing providing the following requirements are followed: • An outside air inlet must be provided for combustion and be unrestricted while unit is in use.
INSTALLATION PAGE 8 TYPES OF CHIMNEYS The chimney is a vital part of your stove installation. A properly built masonry chimney or a properly installed factory built chimney will assu re a consistent draft under a variety of weather conditions (a smoking stove is usu- ally caused by a chimney pr oblem).
INSTALLATION PAGE 9 CHIMNEY HEIGHT REQUIREMENTS The chimney must extend 3 f eet (914 mm) above the level of roof penetration and a minimum of 2 feet (610 mm) higher than any roof surface within 10 feet (305 cm) (see below). Check with your local building officials for any ad- ditional requirements for your area.
INSTALLATION PAGE 10 DRAFT REQUIREMENTS The appliance is merely one component of a larger sys- tem. The other equally import ant component is the vent- ing system which is necessa ry for achieving the re- quired flow of combustion air to the fire chamber and for safely removing unwanted combustion byproducts from the appliance.
INSTALLATION See Pipe Manufacturers Instructions For Installation Requirements Of Venting Components And Vent Clearances. PAGE 11 RESIDENTIAL STANDARD Using 6” (152 mm) Diameter Single Wall Con- nector Pipe. Not Approved For Manufactured (Mobile) Homes.
INSTALLATION - Combustible Wall Chimney Connector Pass-Throughs PAGE 12 NOTES: 1. Connectors to a masonry chimney , excepting method B, shall extend in one continuous section through the w all pass-through system and the chimney w all, to but not past the inner flue liner face.
PRODUCT FEATURES AND CONTROLS CARE AND OPERATI0N PAGE 13 PRIMARY AIR CONTROL The primary combustion air delivery is controlled by the Primary Air Control Assembly (The control handle is lo- cated below the fuel door).
CARE AND OPERATION PAGE 14 PRIMARY AIR CONTROL This appliance is equipped with a control for the combustion air, lo- cated on the lower right side (front) of the stove. Sliding the control to the right increases the burn rate, to the left decreases the burn rate.
FUEL MAINTENANCE PAGE 15 BURN RECOMMENDED FUEL This appliance is approved for use with untreated natural dry wood only (see Important Warnings , page 2, #8). Do not burn particleboard scraps or pressed logs using bonding agents because they can produce conditions which will deteriorate metal.
MAINTENANCE PAGE 16 DOOR AND GLASS GASKETS A 3/4" (19 mm) spun fiberglass rope gasket provides the seal around the fuel door and a 1/8” x 1” (3 mm x 25.4 mm) flat woven gasket glass provides the seal around the glass. Should these gaskets become frayed or damaged they should be replaced with the same size and type as the original gasket.
TROUBLESHOOTING PAGE 17 SMOKES OUT FUEL DOOR WHEN OPEN (see ✸ ) 1. The primary air control is closed. 2. The chimney is too cool. Set the primary air control on "HIGH" for a few minutes before opening the fuel door. 3. Excess creosote will not only re strict your draft but it will create a risk of a creosote fire.
TROUBLESHOOTING PAGE 18 OVERFIRING DAMAGE If the heater or chimney connec tor glows, you are overfir- ing. Other symptoms may include: Cracking, warping or burning out of components, stove glass may develop a haze, which will not come off with cleaning.
SPECIFICATIONS : Model 1400HT PAGE 19 Approx. heat capacity ~1500 Sq. Ft.* ~450 sq. M. Outside air provision Yes Log length 20’’ (508 mm) Flue position Top Flue collar size 6’’ (152 mm) Width 27’’ (686 mm) Depth 21 1/2" (546 mm) Height (to flue) 28” (711 mm) Height 26” (660 mm) Approx.
REPLACEMENT PARTS – Model 1400HT PAGE 20 PART NO. / CAT. NO. DESCRIPTION Door Parts 10500 Door Assembly, Cast Black (handle included) 27M67 Clip Set, Glass 86-128 Door Gasket Kit, 3/4" Rope (in.
REPLACEMENT PARTS – Model 1400HT PAGE 21 FIREBRICK DIAGRAM DOOR ASSEMBLY HANDLE ASSEMBLY (P/N LB-102214) PRIMARY AIR DRAFT MODULE FB-1 FB-1 FB-1 FB-1 FB-1 FB11 FB-1 FB-2 FB-2 FB-2 FB-2 FB-2 FB-2 Must Chip Approximately 1” x 1” Notches to Fit FB-2 FB-2 FB-2 FB5 FB-2 * Baffle Brick 5 ea.
OPTIONAL ACCESSORIES – Model 1400HT Note: Install and use accessories per instructions provided with the accessory kit. PAGE 22 Catalog # Description(Model) Notes 14M66 Outside Air Floor Duct (OAFD-.
SAFETY/LISTING LABEL PAGE 23.
EPA LABEL PAGE 24.
Page 25 OWNERSHIP RECORDS Dealer’s Name: Dealer’s Address: City: State: Zip Code: Serial Number: Date of Purchase: Date Installed: Notes: SERVICE AND MAINTENANCE LOG Service Service Service Date T.
1110 West Taft Avenue Orange, CA 92865.
Een belangrijk punt na aankoop van elk apparaat LG Electronics 1400HT (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen LG Electronics 1400HT heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens LG Electronics 1400HT vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding LG Electronics 1400HT leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over LG Electronics 1400HT krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van LG Electronics 1400HT bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de LG Electronics 1400HT kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met LG Electronics 1400HT . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.