Gebruiksaanwijzing /service van het product SV-iC5 Series van de fabrikant LG Electronics
Ga naar pagina of 141
Important User Information i SV-iC5 Thank you for purchasing LG V ariable Frequency Drives! SAFETY INSTRUCTIONS Always follow safety instructions to prevent accidents and potential hazards from occurring.
Important User Information ii SV-iC5 pinching. Otherwise, you may get an electric shock. CAUTION Inst all the inverter on a non-flammabl e surface. Do not place flam mable material nearby . Otherwise, fire could occur . Disconnect the input power if the inverter get s damaged.
Important User Information i i i SV-iC5 (2) Wiring Do not connect a power factor correction capacitor , surge suppressor , or RFI filter to the output of the inverter . The connection orientation of the output cables U, V , W to the motor wi ll affect the direction of rotation of the motor .
Manual outline iv SV-iC5 Import ant User Information The purpose o f this manual is to prov ide the user with the necessary info rmation to install, program, start up and maintain the SV -iC5 series inverter .
Table of Contents v SV-iC5 Table of Contents 1. Basic information and precautions ..................................................................... 1-1 1.1 Important prec autions ....................................................................
Table of Contents vi SV-iC5 8. Control block diagram ........................................................................................ 8-1 8.1 Frequency and Drive mode setting ....................................................................
Table of Contents v i i SV-iC5 12. Protective functions ...................................................................................... 12-1 12.1 Electronic Th ermal ..............................................................................
Table of Contents viii SV-iC5.
1. Basic information & precautions 1-1 SV-iC5 1. Basic information and precautions 1.1 Important precautions Unpacking and inspection Inspect the inverter for any damage that ma y have occurr ed during shipping.
1. Basic information & precautions 1-2 SV-iC5 1.2 Product Details 1.2.1 Appearance 1.2.2 View without the front cover R efer to Page 1-3 for front co ver removal. Front Cover: Rem o v e i t w he n wiring and changing parameter setting. Bottom Cover: Rem o v e i t w he n wiring input powe r and motor .
1. Basic information & precautions 1-3 SV-iC5 1.3 Removal and reinstallation 1.3.1 R emoval of the front cover To change paramete r setting: Press the patt ern with a fin ger slightly as 1) and push it downward as 2). Then 4-way button will appear.
1. Basic informati on & precautions 1-4 SV-iC5 Removal for wiring input power and termina ls: After removin g the front cover, lift the bottom cover up to disconnect. To access control terminals: after finishing power terminal wiring, reinstall t he bottom cover an d then start wiring control terminal s.
2. Installation 2-1 SV-iC5 2. Inst allation 2.1 Installation precautions CAUTION Handle t he inverter with care to prevent da mage to the pl astic compone nts. Do not hold the inverter by the front cover . It may fall off. Install the inverter in a pl ace where it is immune to vi brati on (5.
2. Install ation 2-2 SV-iC5 When t wo or more inverters are installed or a ventilation fan is mou nted in inverter panel, the inverters and ventilatio n fan must be installed in proper positions with extreme care taken to keep t he ambi ent temperatur e of the inv erters below the permissible va lue.
2. Installation 2-3 SV-iC5 2.2 Dimensions 0.4, 0.75 kW (1/2~1 HP) Dimension 004iC5-1 004iC5-1F 008iC5-1 008iC5-1F W 79 79 79 79 H 143 143 143 143 D 143 143 143 143 We i g h t (Kg) 0.
2. Install ation 2-4 SV-iC5 1.5, 2.2 kW (2~3HP) Dimension 015iC5-1 015iC5-1F 022iC5-1 022iC5-1F W 156 156 156 156 H 143 143 143 143 D 143 143 143 143 We i g h t (Kg) 1.
3. Wiring 3 - 1 SV-iC5 3. Wiring 3.1 T erminal wiring L1 L2 P P1 N U V W Single phase AC input 200V ~ 230V AC line voltage input Terminal for Inverter DC P/S Terminal for motor Common bar L1 L2 PP 1 N.
3. Wiring 3-2 SV-iC5 3.2 S pecifications for power terminal block wiring SV004iC5-1 SV008iC5-1 SV015iC5-1 SV022iC5-1 Input wire size 2mm 2 2mm 2 3.5mm 2 3.5mm 2 Output wire 2mm 2 2mm 2 3.5mm 2 3.5mm 2 Ground Wire 2mm 2 2mm 2 3.5mm 2 3.5mm 2 T erminal Lu g 2mm 2 ,3.
3. Wiring 3-3 SV-iC5 WA R N I N G Use the Type 3 gr ounding meth od (G ro und impeda nce: Below 100 ohm). Use the dedicated ground term inal to ground the invert er. Do not use the screw in the case or chassis, etc for gr ounding. ☞ Note : R emove front and bottom cover before starti ng grounding.
3. Wiring 3-4 SV-iC5 3.3 I/O terminal bl ock specification Terminal Terminal Description Wire size Torque (Nm) Note P1/P2/P3 P4/P5 Multi-function i nput T/M P1-P5 22 AWG, 0.3 mm 2 0.4 CM Common T erminal for P1-P5, AM, P24 22 AWG, 0.3 mm 2 0.4 VR 12V power supply for external potentiometer 22 AWG, 0.
3. Wiring 3-5 SV-iC5 3.4 PNP/NPN selection and co nnector for communication opti on ☞ Note: MODBUS R TU option card is available for SV -i C5. Refer to MODBUS R TU option card manual for more details. CM FX 24X 24I CM CM Resistor Resistor Resistor CPU S4 CM FX 24X 24I CM CM Resistor Resistor Resistor CPU S4 2.
3. Wiring 3-6 SV-iC5 Notes:.
4. Basic configuration 4 - 1 SV-iC5 4. Basic configuration 4.1 Connection of peripheral devices to the inv e rter The following devic es are required to o perate the inverter . Proper peripheral devices must be selected a nd correct connections made to ensure proper op eration.
4. Basic configuration 4-2 SV-iC5 4.2 Recommended MCCB, Earth leakage circuit break er (ELB) and Magnetic contactor specification Model MCCB/ ELB(LG) Magnetic Contactor Note 004iC5-1, 1F ABS33b, EBS333 GMC-12 008iC5-1, 1F ABS33b, EBS333 GMC-18 015iC5-1, 1F ABS33b, EBS333 GMC-25 022iC5-1, 1F ABS33b, EBS333 GMC-32 4.
5. Programming keypad 5 - 1 SV-iC5 5. Programming Keypad 5.1 Keypad features Display FWD Lit during forward run REV Lit during reverse run Blinks when a fault occurs 7-Segment (LED Displ ay) Displays .
5. Programming keypad 5-2 SV-iC5 5.2 Alpha-numeric vie w on the LED keypad 0 A K U 1 B L V 2 C M W 3 D N X 4 E O Y 5 F P Z 6 G Q 7 H R 8 I S 9 J T.
5. Programming keypad 5-3 SV-iC5 5.3 Moving to other groups There are 4 different parameter groups i n SV-iC5 se ries as shown below. Drive group Basic parameters necess ar y for the in verter to run. Parameters such as T arget frequency , Accel/Decel time are settable.
5. Programming keypad 5-4 SV-iC5 How to move to other groups at the 1 st code o f each group. 1 -. The 1 st code in Drive group “0.0” will be displayed when AC input power is applied. -. Press the right arrow ( X ) key once to go to Function group 1.
5. Programming keypad 5-5 SV-iC5 5.4 How to change the codes in a group Code change in Dri ve group 1 -. In the 1 st code in Drive group “0.0”, press the Up ( S ) key once. 2 -. The 2 nd code in Drive group “ACC” is displayed. -. Press the Up ( S ) key once.
5. Programming keypad 5-6 SV-iC5 For changing code from any co des other than F 0 When moving from F 1 to F 15 in Function gr oup 1. 1 -. In F 1, continue pressing the U p ( S ) key until F15 is displayed. 2 -. Moving to F15 has been complete. ♣ The same rule applies to F unction group 2 and I/O group.
5. Programming keypad 5-7 SV-iC5 5.5 Parameter setting method Changing parameter value in Drive group When changing ACC time from 5.0 sec to 16.0 Drive group 1 -. In the first code “0.0”, press the Up ( S ) key once to go to the second code. 2 -.
5. Programming keypad 5-8 SV-iC5 When changing run frequenc y to 30.05 Hz in Drive group Drive group 1 -. In “0.0”, press the Prog/Ent ( z ) key once. 2 -. The second 0 in 0. 0 is active. -. Press the Right ( X ) key once to move the cursor to the right.
5. Programming keypad 5-9 SV-iC5 Changing parameter values in Function 1, 2 an d I/O group When changing the parameter value of F 27 from 2 to 5 Function g rou p 1 1 -. In F0, press the Prog/Ent ( z ) key once. 2 -. Check the present code number .
5. Programming keypad 5-10 SV-iC5 5.6 Monitoring of operation status Monitoring output current in Drive group Drive group 1 -. In [0.0], continue pressing the Up ( S ) or Down ( T ) key until [Cur] is displayed. 2 -. Monitoring output current is provided in this parameter .
5. Programming keypad 5-11 SV-iC5 How to monitor Motor rpm in Drive group when the motor is rotating in 1730 rpm. Drive group 1 -. Present run frequency ca n be monitored in the first code of Functio n group 1. The preset frequency is 57.6Hz. -. Continue pressing the Up ( S ) /Down ( T ) key until rPM is displayed.
5. Programming keypad 5-12 SV-iC5 How to monitor fault condition in Drive grou p Drive group STOP/RST Frequency Current During Accel Over- current trip 1 -. This message appears when an Overcurrent fault occurs. -. Press the Prog/Ent ( z ) key once. 2 -.
5. Programming keypad 5-13 SV-iC5 Parameter initialize How to initialize parameters of all four groups in H93 Function group 2 1 -. In H0, press the Prog/Ent ( z ) key once. 2 -. Code number of H0 is displayed. -. Increase the value to 3 by pressing the Up ( S ) key .
5. Programming keypad 5-14 SV-iC5 Notes:.
6. Basic operation 6-1 SV-iC5 6. Basic operation 6.1 Frequency Setting and Bas ic Operatio n ☞ Caution : The following instructions are given based on the fact that all parameters are set to factory defaults. Results could be different if pa rameter values are changed.
6. Basic operation 6-2 SV-iC5 Frequency Setting via potentiomet er & operating via terminals 1 -. Apply AC input po wer to the inverter . 2 -. When 0.0 appears Press the Up ( S ) key four times. 3 -. Frq is displayed. Frequenc y setting mode is selectable.
6. Basic operation 6-3 SV-iC5 Frequency setting via potentiometer & operating via the Run key 1 -. Apply AC input po wer to the inverter . 2 -. When 0.0 is displayed, press the Up ( S ) key three times. 3 -. drv is displayed. Oper ating method is selectable.
6. Basic operation 6-4 SV-iC5 Notes:.
7. Function list 7-1 SV-iC5 7. Function list Drive Group LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page 0.0 [Frequency command] 0/400 [Hz] T his parameter sets the frequency that the inverter is commanded to output.
7. Function list 7-2 SV-iC5 Drive Group LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page CUr [Output current] This parameter displays the output current to the motor . - - 1 1-1 rPM [Motor RPM] This parameter displays the number of Motor RPM.
7. Function list 7-3 SV-iC5 Function group 1 LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page F 0 [Jump code] 0/60 This parameter sets the p arameter code number to jump.
7. Function list 7-4 SV-iC5 Function group 1 LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page F20 [Jog frequency] 0/400 [Hz] T his parameter sets the frequency for Jog operation. It cannot be set above F 21 – [ Max frequency].
7. Function list 7-5 SV-iC5 Function group 1 LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page F29 [T orque boost in reverse direction] T his parameter sets the amount of torque boost applied to a motor durin g reverse run.
7. Function list 7-6 SV-iC5 Function group 1 LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page F51 4) [Electronic thermal level for 1 minute] 50/200 [%] T his parameter set s max cur rent capable of flowing to the motor continuously for 1 minute.
7. Function list 7-7 SV-iC5 Function group 1 LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page T his parameter stops accelerating during acceleration, decelerating during co nstant speed run and stops decelerating durin g deceleration.
7. Function list 7-8 SV-iC5 Function group 2 LED display Parameter name Min/Max range De scription Factory default s Adjustable during run Page H 0 [Jump code] 1/95 This parameter sets the code number to jump.
7. Function list 7-9 SV-iC5 Function group 2 LED display Parameter name Min/Max range De scription Factory default s Adjustable during run Page H16 [Skip frequency high limit 3] 35.0 X H17 S-Curve accel/decel start side 1/100 [%] Set the speed referenc e value to form a curve at the start during accel/decel.
7. Function list 7-10 SV-iC5 Function group 2 LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page T his parameter is active to prevent any possible fault when the inverter outputs its voltage to the running motor .
7. Function list 7-11 SV-iC5 Function group 2 LED display Parameter Name Min/Max Range Description Factory default s Adjustable during run Page H26 [Number of Auto Restart try] 0/10 This parameter sets the number of restart tries after a fault occurs.
7. Function list 7-12 SV-iC5 Function group 2 LED display Parameter Name Min/Max Range Description Factory default s Adjustable during run Page Select one of the foll owing according to motor inertia.
7. Function list 7-13 SV-iC5 Function group 2 LED display Parameter Name Min/Max Range Description Factory default s Adjustable during run Page H51 [P gain for PID controller] 0/999.9 [%] 300.0 O 10-8 H52 [Integral time for PID controller (I gain)] 0.
7. Function list 7-14 SV-iC5 Function group 2 LED display Parameter Name Min/Max Range Description Factory default s Adjustable during run Page 5 Multi-S tep frequenc y 1 6 Multi-S tep frequenc y 2 7 .
7. Function list 7-15 SV-iC5 Function group 2 LED display Parameter Name Min/Max Range Description Factory default s Adjustable during run Page H86 [2 nd motor reverse torque boost] 5 X H87 [2 nd moto.
7. Function list 7-16 SV-iC5 I/O group LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page I 0 [Jump code] 0/63 This parameter sets the code number to jump 1 O 5-5 I 1 [Filter time constant for V0 input] 0/9999 This is used to adjust the anal og voltage input signal via keypad potentiometer .
7. Function list 7-17 SV-iC5 I/O group LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page I13 [Frequency corresponding to I 12] 0/400 [Hz] Set the inverter output minimum frequenc y at minimum current of I input.
7. Function list 7-18 SV-iC5 I/O group LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page 16 Frequency decrease command (DOWN) 17 3-wire operation 10-4 1.
7. Function list 7-19 SV-iC5 I/O group LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page I36 [Multi-Accel time 2] 4.0 I37 [Multi-Decel time 2] 4.0 I38 [Multi-Accel time 3] 5.0 I39 [Multi-Decel time 3] 5.
7. Function list 7-20 SV-iC5 I/O group LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page I52 [Frequency detection level] 30.
7. Function list 7-21 SV-iC5 I/O group LED display Parameter name Min/Max range Description Factory default s Adjustable during run Page 2 - 3 - 3 - 3 3 4 3 - - 5 3 - 3 6 3 3 - 7 3 3 3 I60 [Inverter station number] 1/32 This parameter is set when the inverter uses RS485 communication.
.
8. Control block diagram 8-1 SV-iC5 8. Control block diagram Frequency setting Drive mode Accel/Decel V/F control PWM Motor.
8. Control block diagram 8-2 SV-iC5 8.1 Freque ncy and Drive mode setting I/O group St1 St2 St3 I/O group I30 I31 I32 I33 Step 0 I/O group I20 ~ I24 Step 0-7 Step freq.
8. Control block diagram 8-3 SV-iC5 8.2 Accel/Decel setting and V/F control Reference freq. for Accel/Decel Accel/Decel time P1 P2 P3 P4 P5 Digital input filter Multi-Accel/Decel time select 5,6,7 P1 ~ P5 Max freq. 0 1 Accel/Decel pattern S-cu rve 1 Linear 0 Stop method select 0 1 2 DC brake FreeRun Stop DC brake freq.
.
9. Basic functions 9-1 SV-iC5 9. Basic Functions 9.1 Frequenc y mode Digital Frequenc y setting via Keypad 1 Group LED Display Parameter Name Set Va l u e Min/Max Range Factory Defaults Unit 0.0 [Frequency Command] - 0/400 0.0 Hz Drive group Frq [Fre quency mode] 0 0/8 0 Run freque ncy is settable in 0.
9. Basic functions 9-2 SV-iC5 Analog Fr eq uency setting via Potentiometer (V0) on the Ke ypad Used to prevent fluctuations in anal og i nput signals caused by noise Group LED Display Paramete r Na me Set Va l u e Min/Max Range Factory Defaults Unit 0.
9. Basic functions 9-3 SV-iC5 Analog Freq uency setting via V oltage analog input (0-1 0V) or potentiometer on the VR terminal Group LED Display Parameter Name Set Va l u e Min/Max Range Factory Defaults Unit 0.
9. Basic functions 9-4 SV-iC5 Frequenc y setting via Potentiometer on the keypad + Current Analog in p ut (0-20mA) Group LED Display Parameter Name Set Va l u e Min/Max Range Factory Defaults Unit 0.
9. Basic functions 9-5 SV-iC5 Frequenc y setting via Potentiometer on the keypad + 0-10V input Group LED Display Parameter Name Set Va l u e Min/Max Range Factory Defaults Unit 0.0 [Frequency Command] - - - Hz Drive group Frq [Frequency Mode] 7 0/8 0 Set Frq – [Freque ncy Mode] to 7 {Potentio meter on the keypad + 0-10V input}.
9. Basic functions 9-6 SV-iC5 9.2 Multi-S tep frequency setting Group L ED Display Paramete r Name Set Va l u e Min/Max Range Factory Defaults Unit 0.0 [Frequency command] 5.0 0/400 0.0 Hz Frq [Frq mode] 0 0/8 0 - St 1 [Multi-S tep frequenc y 1] - 10.
9. Basic functions 9-7 SV-iC5 9.3 Run Command setting Run via the Run and STOP/RST key Group LED Disp lay Parameter Name Set Va l u e Min/Max Range Facto ry Defaults Unit drv [Drive mode] (Run/Stop mode ) 0 0/3 1 Drive group drC [Direction of motor rotation select] - F/r F Set drv – [Drive mode] to 0.
9. Basic functions 9-8 SV-iC5 Run command setting 2 at FX and RX terminals Group LED Display Parameter Name Set Va l u e Min/Max Range Factory Defaults Unit Drive group drv [Drive mode] (Run/Stop .
9. Basic functions 9-9 SV-iC5 Power On S tart select Group LED Disp lay Parameter Name Set Va l u e Min/Max Range F actory Defaults Unit Drive group drv [Drive mode] (Run/Stop mode ) 1, 2 0/3 1 Function group 2 H20 [Power On St art select] 1 0/1 0 Set H20 to 1.
9. Basic functions 9-10 SV-iC5 9.4 Accel/Decel ti me and u nit setting Accel/Decel ti me setting bas ed on Max frequenc y Group LED Disp lay Parameter Name Set Va l u e Min/Max Range Factory Defaults Unit ACC [Accel time] - 0/600 0 5.0 sec Drive group dEC [Decel time] - 0/6000 10.
9. Basic functions 9-11 SV-iC5 More precise time unit can be set correspon ding to load characteristics as shown below . Code Parameter Name Setting range Set value Descripti on 0.01~600.00 0 Unit: 0.01 sec. 0.1~6000.0 1 Unit: 0.1 sec. H71 [Accel/Decel T ime setting unit] 1~60000 2 Unit: 1 sec.
9. Basic functions 9-12 SV-iC5 Multi-Accel/Decel time setting via Multi-function terminals Group LED Disp lay Parameter Name Set Va l u e Min/Max Range Factory Defaults Unit ACC [Accel time] - 0/6000 5.0 Sec Drive group dEC [Decel time] - 0/6000 10.
9. Basic functions 9-13 SV-iC5 Accel/Decel pattern setting Group LED display Parameter name Min/Max range Set value Unit F 2 [ Accel p attern] 0 Linear Function group 1 F 3 [Decel pattern] 1 S-curve 0 H17 S-Curve accel/decel st art side 40 % H18 S-Curve accel/decel end side 1~100 40 % Accel/Decel pattern is settable at F2 and F3.
9. Basic functions 9-14 SV-iC5 Note that setting Freque ncy R e f for Acce l/decel (H70) is set to Max Freq an d target freq is set belo w Max freq.
9. Basic functions 9-15 SV-iC5 9.5 V/F control Linear V/F ope ration Group LED Display Parameter Name Set Va l u e Min/Max Range Factory Defaults Unit F22 [Base frequency] - 30/400 60.0 Hz F23 [S tart frequency] - 0/10.0 0.5 Hz Function group 1 F30 [V/F pattern] 0 0/2 0 Set F30 to 0 {Linear}.
9. Basic functions 9-16 SV-iC5 User V/F pattern Group LED display Parametername Set valu e Min/Max range Factory default s Unit F30 [V/F p attern] 2 0/2 0 F31 [User V/F frequency 1] - 0/400 15.0 Hz ~ ~ Function group 1 F38 [User V/F voltage 4] - 0/100 100 % Select F30 to 2 {User V/F}.
9. Basic functions 9-17 SV-iC5 Manual T orque Boost Group LED display Parameter name Set Va l u e Min/Max range Factory default s Unit F27 [T orque boost select] 0 0/1 0 F28 [T orque boost in for ward direction] Function group 1 F29 [T orque boost in reverse direction] - 0/15 5 % Set F27 to 0 {Manu al torq ue boost}.
9. Basic functions 9-18 SV-iC5 9.6 S top mode sel ect Decel to stop Group LED Display Para mete r Name Set Va l u e Min/Max Range Factory Defaults Unit Function group 1 F4 [Stop mode select] 0 0/2 0 Set F30 to 0 {Decel to stop}. T he inverter de celerates to 0Hz for the preset time.
9. Basic functions 9-19 SV-iC5 9.7 Frequency lim it setting Freque nc y limit setting based on Ma x and start frequency Group LED display Paramete r name Set valu e Min/Max range Factory default s Unit F21 [Max fre quency] - 0/400 60.0 Hz Function group 1 F 23 [S tart frequency] - 0/10 0.
9. Basic functions 9-20 SV-iC5 Skip frequenc y Group LED display Paramete r name Set valu e Min/Max range Factory default s Unit H10 [Skip frequency select] 1 0/1 0 H1 1 [Skip frequency low lim it 1] - 0/400 10.0 Hz ~ ~ Function group 2 H16 [Skip frequency high limit 3] - 0/400 35.
10. Advanced functions 10-1 SV-iC5 10. Advanced functions 10.1 DC brake S top mode via DC brake Group LED Display Parameter Name Set valu e Min/Max Range Factory Defaults Unit F 4 [Stop mode select] 1 0/2 0 F 8 [DC Brake start frequency] - 0/60 5.
10. Advanced functions 10-2 SV-iC5 S tarting DC brake Group LED Display Para mete r Name Set valu e Min/Max Range Factory Defaults Unit F12 [DC Brake st art voltage] - 0/200 50 % Function group 1 F13 [DC Brake start time] - 0/60 0 sec F12 : It sets the level as a percent of H33 – [Motor rated current].
10. Advanced functions 10-3 SV-iC5 10.2 Jog operation Group LED display Parameter name Set valu e Min/Max range Factory default s Unit Function group 1 F20 Jog frequency - 0/400 10.0 Hz I/O group I22 [Multi-function input terminal P3 define] 4 0/24 2 Set the desir ed jog frequency in F20.
10. Advanced functions 10-4 SV-iC5 10.3 Up-Down operation Group LED display Parameter name Set valu e Min/Max range Factory default s Unit I20 [Multi-function input terminal P1 define] 0 2 ~ ~ I23 [Mu.
10. Advanced functions 10-5 SV-iC5 If both 3-Wire and Up-Down operation are se lected, the former will be ignored. The bandwidth of pulse (t) should be above 50msec. S peed search oper ation is valid even in the case of L V T (low voltage trip) following instant power failure.
10. Advanced functions 10-6 SV-iC5 Example Rated frequency = 60Hz Rated RPM = 1740rpm Number of motor poles= 4 Hz f s 2 120 4 1740 60 = × − = 10.6 Slip compensation Group LED Display Parameter Name Set valu e Min/Max Range Factory Defaults Unit H30 [Motor type select] - 0.
10. Advanced functions 10-7 SV-iC5 H32 : Enter the slip frequency base d on the f ollowing formula and motor namepl ate. × − = 120 P rpm f f r s Where, s f = Rated slip .
10. Advanced functions 10-8 SV-iC5 10.7 PID Control Group LED Disp lay Parameter Na me Set valu e Min/Max Range Factory Defaults Unit H40 [Control mode select] 2 0/3 0 - H50 [PID Feedback select] - 0/1 0 - H51 [P gain for PID controller] - 0/999.9 300.
10. Advanced functions 10-9 SV-iC5 PID control block diagram Control mode select Func. group2 H40 Keypad setting 2 V0:Potentiometer V1 : 0 ~ 10V I : 0 ~ 20mA Ref.
10. Advanced functions 10-10 SV-iC5 10.8 Auto tuning Group LED Disp lay Parameter Name Set valu e Min/Max Range Factory Defaults Unit H41 [Auto tuning] 1 0/1 0 - H42 [S tator resistance (Rs)] - 0/14.0 - Ω Function group 2 H44 [Leakage inductance (L σ )] - 0/300.
10. Advanced functions 10-11 SV-iC5 10.9 Sensor less vector control Group LED Disp lay Parameter Name Set valu e Min/Max Range Factory Defaults Unit H40 [Control mode select] 3 0/3 0 - H30 [Motor type select] - 0.2/2.2 - kW H32 [Rated slip frequency] - 0/10 - Hz H33 [Motor rated current] - 1.
10. Advanced functions 10-12 SV-iC5 F actory defaul t of motor parameters (Function group 2) H30-Motor rat i ng [kW] H32-Rated slip freq [Hz] H33-Current rat i ng [A] H34-No-load current [A] H42-Stator resistance [ Ω ] H44-Leaka ge inductance [mH] 0.
10. Advanced functions 10-13 SV-iC5 The following table shows 4 types of S peed search selection. S peed search during H20 – [Power ON start] S peed search during Instant Power Failure restart S.
10. Advanced functions 10-14 SV-iC5 EX) S peed search duri ng Instant Power Failure restart When the i nput power is cut off due to inst ant power failure, the inverter outputs Low voltage trip (L V) to hold t he outp ut.
10. Advanced functions 10-15 SV-iC5 10.12 Auto restart tr y Group LED Display Paramete r Name Set valu e Min/Max Range Factory Defaults Unit H26 [Number of Auto Rest art try] - 0/10 0 Function group 2 H27 [Auto Restart time] - 0/60 1.0 Sec T his parameter sets the number of times auto restart is activated in H26.
10. Advanced functions 10-16 SV-iC5 Carrier frequency select Group LED Disp lay Parameter Name Set valu e Min/Max Range Factory Defaults Unit Function group 2 H39 [Carrier frequ ency select] - 0/15 10 T his parameter affect s the sound of the inv erter during operation.
10. Advanced functions 10-17 SV-iC5 Used when an inverter operat es 2 motors connec ted to two different types of the loads. 2 nd motor operation do es no t run 2 motors at the same time.
10. Advanced functions 10-18 SV-iC5 Pass word Register Group LED Disp lay Parameter Name Set valu e Min/Max Range Factory Defaults Unit Function group 2 H94 [Passw o rd Register] - 0/FFF 0 H95 [Parameter lock] - 0/FFF 0 T his parameter creates password for H95 – [Parameter lock].
10. Advanced functions 10-19 SV-iC5 Parameter Lock Group LED Display Parameter Name Set valu e Min/Max Range Factory Defaults Unit H95 [Parameter lock] - 0/FFF 0 Function group 2 H94 [Password Regi ster] - 0/FFF 0 T his parameter is used to lock the user-set parameters using the password.
10. Advanced functions 10-20 SV-iC5 Notes:.
11. Monitoring 11-1 SV-iC5 11. Monitoring 11.1 Operatin g status monitoring Output current Group LED Display Description Set valu e Min/Max range Factory default Unit Drive group CUr Output current - Inverter output current can be monitored in Cur .
11. Monitoring 11-2 SV-iC5 User displa y s elect Group LED Display Para meter Name Set valu e Min/Max range Factory default Unit Drive group vOL [User display select] - Function group 2 H73 [Monitoring item select] - 0/2 0 T he selected item in H73- [Monitoring item select] can be monitored in vOL- [User display select].
11. Monitoring 11-3 SV-iC5 11.2 Monitoring the I/O terminal Input terminal status monitoring Group LED Display Parameter Name Set valu e Min/Max range Factory default Unit I/O group I25 [Input terminal status display] - Active input terminal status (ON/OFF) can be monitored in I25.
11. Monitoring 11-4 SV-iC5 11.3 Monitori ng fault condition Monitoring faul t display Group LED Display Para meter Name Set valu e Min/Max range Factory default Unit Drive group nOn [Fault Display] - T he kind of fault occurred during operation is displ ayed in nOn.
11. Monitoring 11-5 SV-iC5 11.4 Analog Output Group LED Display Parameter Name Set valu e Min/Max range Factory default Unit I50 [ Ana log output item select] - 0/3 0 I/O group I51 [Analog output leve l adjustment] - 10/200 100 % Output item and the leve l from the AM terminal are selectable and adjustable.
11. Monitoring 11-6 SV-iC5 11.5 Multi-function output te rminal (MO) and Relay (30AC) Group LED display Para meter Name Setting Factory default 0 FDT -1 I54 [Multi-function output terminal select] 1 F.
11. Monitoring 11-7 SV-iC5 I56: When 17 {Fault dis play} is selected in I 54 and I55, Multi-function out put terminal and relay will be activated with the value set in I56. 0 : FDT -1 Check whether the output frequenc y of the i nverter matches the user-setting frequency .
11. Monitoring 11-8 SV-iC5 2 : FDT -3 It activates when run frequency meets the following condition. Active condition: Absolute val ue (F DT level - run frequency) <= FDT Bandwidth/2 Group LED Display Para meter Name Set valu e Min/Max range Factory default Unit I52 [Frequency Detection level] - 30.
11. Monitoring 11-9 SV-iC5 4 : FDT -5 Activated as B contact contrast to FDT -4. Active condition Accel time: Run Frequency >= FDT Level Decel time: Run Frequenc y > (FDT Level – FDT Bandwid th/ 2) Group LED Display Para meter Name Set valu e Min/Max range Factory default Unit I/O group I52 [Frequency Detection Level] - 30.
11. Monitoring 11-10 SV-iC5 1 1: Command Loss Become active when frequenc y command is lost. 12: During run Become active when run command is g iven and the inverter generates out put voltage. 13: During stop Activated during stop. 14: During constant run Activated during nominal oper ation.
12. Protective functions 12-1 SV-iC5 12. Protective functions 12.1 Electronic T hermal Group LED display Parameter Name Set v alue Min/Max setting Factory default Unit F50 [Electronic therm al select].
12. Protective functions 12-2 SV-iC5 12.2 Overloa d W ar ning and trip Overload warning Group LED Display Parameter Name Set valu e Min/Max setting Factory default Unit F54 [Overload warning level.
12. Protective functions 12-3 SV-iC5 Overload trip Group LED Display Parameter Name Set valu e Min/Max setting Factory default Unit F56 [Overload trip select] 1 0/1 0 F57 [Overload trip level] - 30/200 180 % Function group 1 F58 [Overload trip time] - 0/60 60 sec Set F56 to 1.
12. Protective functions 12-4 SV-iC5 For example, set F59 to 3 to make stall preventio n active during Acceleration and constant run. When stall prevention is executed during acceler ati on or deceleration, Accel/Decel time may take longer than the user-setting time.
12. Protective functions 12-5 SV-iC5 12.4 Output phase loss protection Group LED display Parameter Name Set valu e Min/Max setting Factory default Unit Function group 2 H19 [Output phase lo ss protection select] 1 0/1 0 Set H19 value to 1.
12. Protective functions 12-6 SV-iC5 12.6 Inverter Overlo ad Inverter overload prevention functio n is activated when the current abov e inverter rated c urrent flows. Multi-function output terminal (MO) or Multi-function r elay (30AC) is used as the alarm signa l output during inverter overload trip.
12. Protective functions 12-7 SV-iC5 12.7 F requency command loss Group LED display Paramete r Na me Set valu e Min/Max setting Factory default Unit I16 [Criteria for analog input signal loss] 0 0/2 0 I62 [Drive mode select after loss of frequency command] - 0/2 0 I63 [Wait time af ter loss of frequency command] - 1.
12. Protective functions 12-8 SV-iC5 0 Continuous operation with the frequency before command loss occurs 1 Free run stop (output cut off) I62 [Drive mode select after loss of frequency command] 2 Dec.
13. Troubleshooting & Maintenance 13-1 SV-iC5 13. T roubleshooting & Maintenance 13.1 Protective functions When a fault occurs, the cause must be cor rected before the fa ult can be clear ed. If protective function keeps active, it could lead to reduction in product life an d da mage to the equipment.
13. Troubleshooting & Maintenance 13-2 SV-iC5 Keypad display Protective functions Descriptions Inverter hardware fault This fault message is displaye d when an error occurs i n the control circuitry of the inverter . Communication Error This fault message is displaye d when the inve rter cannot communicate with the keypad.
13. Troubleshooting & Maintenance 13-3 SV-iC5 13.2 Fault Remedy Protective functions Cause Remedy ☞ Caution: When an o vercurrent fault occurs, o peration must be started after the cause is remo ved to avoid damage to I GBT inside the inv erter .
13. Troubleshooting & Maintenance 13-4 SV-iC5 Protective functions Cause Remedy External fault A contact input External fault B contact input The terminal which is set to “18 (Exter nal fault-A)” or “19 (External fault-B)” in I20-I24 in I/O group is ON.
13. Troubleshooting & Maintenance 13-5 SV-iC5 13.3 Precauti ons for maintenance and inspection CAUTION Make sure to remove the input power whil e performing mainte nance. Make sure to perform mainte nance afte r checking the DC link capacitor has discharged.
13. Troubleshooting & Maintenance 13-6 SV-iC5 Notes:.
14. Specifications 14-1 SV-iC5 14. Specifications 14.1 T echnical data Input & output ratings Model : SV xxx iC5 – 2x 004 008 015 022 [HP] 0.
14. Specifications 14-2 SV-iC5 Multi-function relay terminal Fault output (N.O., N.C.) Analog output 0 ~ 10 Vdc : Frequency , Current, V oltage, DC link voltage selectable Protective functions Inv.
14. Specifications 14-3 SV-iC5 14.2 T emperature Derating Information Load current VS Carrier frequen c y ☞ Note : 1. The ab ove gr aph is a pplie d when inve rter is in use wi thin the permissible ambient temp.
.
i DECLARA TION OF CONFORMITY Council Directive(s) to which conformity is declared: CD 73/23/EEC and CD 89/336/EEC Units are certified for compliance with: EN 50178:1998 EN 50081-2:1993 EN 5501 1:1998+.
ii TECHNICAL ST ANDARDS APPLIED The standards applied in order to comply with the essent ial requirements of the Directives 73/23/EEC "Electrical material intended to be us ed with certain limits.
iii EMC INST ALLA TION GUIDE LG inverters are tested to meet Elec tromagnetic Compatibilit y (EMC) Directive 89/336/EEC and Low V oltage (L V) Directive 73/23/EEC using a techn ical construction file.
iv Revision History No. Revision Date Remarks 1 First Edition 2002. 12 S/W V ersion: 1.3 2 S/W version update 2003. 10 S/W V ersion: 1.5.
LG LG Industrial Systems Co., Lt d. LGIS constan tly endeavors to improve it s product so that information in this manual is subject to chang e witho ut notice.
Een belangrijk punt na aankoop van elk apparaat LG Electronics SV-iC5 Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen LG Electronics SV-iC5 Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens LG Electronics SV-iC5 Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding LG Electronics SV-iC5 Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over LG Electronics SV-iC5 Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van LG Electronics SV-iC5 Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de LG Electronics SV-iC5 Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met LG Electronics SV-iC5 Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.