Gebruiksaanwijzing /service van het product LF300CP(LP-C303R20), LF480CE(LP-C483TA0) van de fabrikant LG
Ga naar pagina of 47
Floor Standing T ype Air Conditioner SER VICE MANU AL MODEL: LF300CP(LP-C303R20) LF480CE(LP-C483T A0).
Contents –2– Safety Precautions ..................................................................................................................3 Functions .........................................................................................
–3– Safety Precautions T o prev ent injur y to the user or other people and proper ty damage, the f ollowing instructions must be f ollow ed. ■ Incorrect operation due to ignoring instruction will cause har m or damage. The seriousness is classified by the f ollowing indications.
–4– ■ Operational Do not install, remove, or re- install the unit by y ourself (customer). • There is risk of fire, electric shock, e xplosion, or injur y . Be cautious when unpacking and installing the product. • Shar p edges could cause injury .
–5– ■ Installation Do not open the inlet grill of the product during operation. (Do not touch the electr ostatic filter , if the unit is so equipped.) • There is risk of physical injury , electric shock, or product f ailure. Be cautious that water could not enter the product.
–6– Keep le vel even when installing the pr oduct. • T o av oid vibration or w ater leakage. Use two or more people to lift and transport the product. • A v oid personal injur y . Use a soft cloth to c lean. Do not use har sh detergents, solvents, etc.
– 7 – Indoor Unit P ower Switc h ON/OFF Operation Mode Control Indoor Fan Speed Contr ol Room T emperature control Sensing Heat Exchanger T emperature Soft Dry Operation Mode Time Delay Saf ety Co.
– 8 – • Intermittent operation of fan at lo w speed. • Used to circulate room air without cooling. • OFF Timer (1, 2, 3,......7 hour) • Airflow direction A uto-swing and Manual Contol. • Up: up to 30 ° C(86.0 ° F) • Down: do wn to 16 ° C(60.
– 9 – Outdoor Unit Deice Control Outdoor Fan Speed Contr ol Sensing Heat Exchanger T emperature • De-ice PCB (Heating Model Only) • One speed • Heat e xchanger temperature sensor (Thermistor.
Pr oduct Specifications – 10 – PO WER SOURCE ( ø , V , Hz) COOLING CAP ACITY BTU/h W INPUT W CURRENT A HEA TING CAP ACITY BTU/h W INPUT W CURRENT A MAKER TYPE COMPRESSOR MODEL CAP ACITY BTU/h CUR.
– 11 – Cool air outlet(2 sides) by Manual operation Cool air outlet(front side) Top/Bottom Airflow Controller Left/Right Airflow Controller Sliding Clean Door Display Panel Antibiotic Filter Air I.
Indoor Unit Outdoor Unit – 12 – 800mm(31.5inch) 180mm(7.1inch) 101mm(4.0inch) 370mm(14.6) 340mm(13.4inch) 95mm 870mm(34.3inch) 320mm(12.6inch) 546mm(21.5inch) 5 3 1 2 4 1820mm(71.7inch) 570mm(22.4inch) 311mm(12.2inch) 180mm(7.1inch) 101mm(4.0inch) No .
Air Intake Vent (Rear) Air Outlet Vent Piping Air Outlet Vent Remote Signal Receptor Air Intake Vent – 13 – Indoor Unit : LPNC483T A0 (LF480CE) door Unit : LPUC483T A0 (LF480CE).
– 14 – Indoor Unit Outdoor Unit 370mm(14.6inch) 125mm(4.9inch) 210mm(8.3inch) 210mm(8.3inch) 290mm(11.4inch) 290mm(11.4inch) 1220mm(48.0inch) 460mm(18.1inch) 460mm(18.1inch) 505mm(19.9inch) 505mm(19.9inch) 90mm(3.5inch) 130mm(5.1inch) 130mm(5.1inch) 640mm(25.
Wiring Diagram 1. LF300CP(LP-C303R20) Outdoor – 15 –.
– 16 – 2. LF480CE(LP-C483T A0) Outdoor.
– 17 – 1. Time Delay Saf ety Control 3min The compressor is ceased f or 3 minutes to balance the pressure in the refrigeration cycle. (Protection of compressor) 3sec The indoor f an is ceased for 3 seconds to pre vent rela y noise. (Protection of f an relay and micro chip) 30sec The 4-wa y v alve is ceased f or 30 sec.
– 18 – 5. Heating Mode Operation The unit will operate according to the setting b y the remote controller and the operation diagram is sho wn as f ollowing. Intake Air T emp. Setting T emp. (Compressor ON) Setting T emp. -1 ° C(1.8 ° F) Indoor F an Speed Compressor ON OFF ON OFF OFF Hot Star t minimum 10sec.
– 19 – 6. Hot-Start Control • The indoor f an stops until the ev aporator piping temperature will be reached to 28 ° C(82.4 ° F). • During heating operation, if piping temperatures f all below 26 ° C(78.8 ° F) f an stops. • The operation diagr am is as follo wing.
– 20 – 11. Child Lock function This function is to operate Air conditioner only b y Remocon. The procedure is as the f ollowing 1st : Press the 2 b uttons of the temperature control simultaneously , to raise-to lower on the Displa y Panel of the product f or more 3 seconds.
12. Alarm mode display / onl y displa yed while operating. CO : The sensor f or sensing room temperature is open or shor t. C1 : The sensor f or sensing piping temperature is open or shor t. 13. Energy Sa ving ➀ If setting temperature of star ting energy sa ving operation is under 22 ° C(71.
3. Setting the set temperature when heating operation. Room temperature < Set temperature: to be set to the pre vious set temperature. Room temperature ≥ Set temperature a) Room temperature ≤ 20 ° C(68.0 ° F)(: to be set to 23 ° C(73.4 ° F) b) 21 ° C(69.
– 23 – 1. Selection of the best location 1) Indoor unit • There should not be any heat source or steam near the unit. • There should not be any obstacles to pre vent the air circulation. • A place where air circulation in the room will be good.
–24– 2. Indoor Unit installation The mounting floor should be strong and solid enough to pre vent it from vibr ation. Drill the piping hole with 2.8 inch diameter hole- core drill at either the r ight or the left of indoor unit. The hole should be sightly slant to the outdoor side.
– 25 – 1. PRECA UTIONS IN TEST RU N • The initial po wer supply must provide at least 90% of the r ated voltage . Otherwise, the air conditioner should not be operated.
– 26 – CA UTION After the confir mation of the abo ve conditions , prepare the wiring as follo ws: 1) Never fail to have an individual po wer specialized for the air conditioner . As for the method of wiring, be guided by the cir cuit diagram pasted on the inside of contr ol bo x cover .
T r oubleshooting Guide – 27 – Failures to Start Check of circuit break er and fuse. Check control s witch. F an only fails to star t Improper wiring Def ect of fan motor capacitor . Irregular motor resistance ( Ω ) Irregular motor insulation ( Ω ) Replacement of f an motor .
– 28 – P A CKA GE AIR CONDITIONER V OL T A GE LIMITS No cooling and heating operation perf ormed NAME PLA TE RA TING MINIMUM MAXIMUM 380 V 342 V 418 V 220 V 198 V 242 V 380 - 415 V 342 V 456 V 2) .
– 29 – 3) Only outdoor fan does not w ork WHA T TROUBLED COMPLAINTS HO W T O CHECK REMED Y Motor Electric Wir ing Over-heated La yer shor t Open wire on operation Shor t circuited on operation Check ho w it is insulated. Check it with a tester . Repair or replace it.
– 30 – Note: Use an appropriate measuring instr ument f or readjustment. *1: Check the High-pressure s witch indication. *2: Check the Lo w- pressure s witch indication. WHA T TROUBLED COMPLAINTS HO W T O CHECK REMED Y Other par ts than the unit Outdoor coil In-condensable gas blended.
– 31 – The unit is w orking, but not cooling and heating sufficientl y (Both blo wer and compressor are working) WHA T TROUBLED COMPLAINTS HO W T O CHECK REMED Y Load Air flow Shor t air volume Refrigerant Air passage Air filter Much heat load Obstacle disturbs Intake of unif or m wind.
– 32 – WHA T TROUBLED COMPLAINTS HO W TO CHECK REMED Y Electric troubles (Magnetic contactor) Others Def ective contact. Def ective contact point. Rusting and f aults in the iron core contact f ace. Def ectiv e contact of the operating s witch. Improper installation Checking Checking Repair and clean or replace it.
– 33 – Fault Cause Check/Correcitve Action Internal Thermostat Cut-Off Ov ercurrent R el ay fo r Compressor Cut-Off Overcurrent Rela y for F an Motor Cut-Off Fuse Blown Disconnection and F aulty Contact Discharge pressure is lower than standard. Single or three phases running.
– 34 – 1) No cooling operation performed. YES YES NO NO NO NO NO NO YES YES YES YES Is the A C220V (A C 240 V) between Connector(CN- outunit) Pin 1 and Pin 3 of Main P .C .B ON/OFF S/W ON Is the unit operating? Is the input power A C220V (AC240V) at COMP Magnetic coil? Check the magnetic contactor of outdoor unit.
– 35 – 2-1) Indoor fan does not operate YES YES YES YES YES YES YES YES YES YES NO NO NO NO NO NO NO NO NO NO Is the unit operating? Is the DC5V at 20pin of (MICOM)? Is the DC5V at 21pin of (MICOM.
– 36 – 3) Airflow Direction does not operate. YES NO YES NO YES NO YES NO YES NO Is the unit operating? Is the Auto Swing S/W "ON"? Is the DC5V at 16 terminal? (MICOM) Is the DC12V at each ter minal? (R Y -Sync COIL) Check the synchronous motor winding.
– 37 – 4) Remote control does not operate. YES NO YES NO YES NO YES NO Is the batter y of remote controller nor mal? Check the connector . CN-Disp1 Is the CN-Disp1 connector nor mal? Does the oper.
– 38 – 5) The unit does not operate. YES NO YES NO YES NO YES NO 6) Timer control does not operate. Replacement Micom Is the A C220V (240V) at T rans input terminal? Is the A C12-18V at T rans (2nd)? Is the connector of Main/Displa y correct? Is the DC5V between PIN64 and PIN 32 of MICOM? Replacement Main PCB ASM 1.
– 39 – 7) No heating operation works YES YES NO NO NO NO NO NO NO NO NO NO NO YES YES YES YES YES YES YES YES YES ON/OFF S/W ON Is the AC220V (A C 240 V) between connector (CN-outunit) Pin 1 and Pin 3 of Main P .
– 40 – 8) No heater operation works YES NO YES NO YES NO YES NO YES NO YES NO Is the heating operating? Is the Compressor operating? Is the Heat S/W of Main PCB "ON"? Heat S/W "ON&q.
Exploded Vie w and Replacement P ar ts List – 41 – 267110 237201 135313-1 135313-2 235811-2 235811-1 137211 132100 235512 249941 268711-1 249951 159830 W0CZZ 268711-2 1.
– 42 – 130911 35211C 354210 W4811-1 567480-3 Eva-out 336610 W4810-1 730700 346810 359012 W1NF 140570 W1WE 349480 567480-1 Inlet-air 159830-1 337000 266000 352150 336600 W4810-2 W4811-2 135515 W521.
– 43 – 268711-3 268711-1 567480-1 Inlet-air 567480-3 Eva-out W4810-2 137211 237202 35211A 35211C 152302 135313 330870 146812 W4810-1 354210 552111 W4811 267110 135080-2 135310 146811 135080-1 1350.
– 44 – 359012 346810 150170 130400 349480 135317 135500 268711-2 249941 249951 W4810 W0CZZ 336610 135515 130911 349600.
2. Outdoor Unit • Model : LF300CP(LP-C303R20) –45– 435512 437210 349480-1 447910 559010 546810 349600 W0CZZ-2 W0CZZ-1 W6920 W5210D 552113 552201 554160-1 554160-2 552200 661400 649950 554030 137213-1 435300 137213-2 435511 552203-1 552203-2 430410 435301 268711-4 548490 567480-4 552112 Air Accum.
– 46 – • Model : LF480CE(LP-C483T A0) 437212 435512 435301 437210 559010 137213 435511 546810 447900 554031 552203-2 552203-1 430411 349600-1 W5210D 554160 552112 552201 552200 661400 552113 649950 W0CZZ-1 268711-4 567480-4 Air Accum.
P/No.: 3828A20156T December, 2006 Printed in Korea.
Een belangrijk punt na aankoop van elk apparaat LG LF300CP(LP-C303R20), LF480CE(LP-C483TA0) (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen LG LF300CP(LP-C303R20), LF480CE(LP-C483TA0) heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens LG LF300CP(LP-C303R20), LF480CE(LP-C483TA0) vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding LG LF300CP(LP-C303R20), LF480CE(LP-C483TA0) leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over LG LF300CP(LP-C303R20), LF480CE(LP-C483TA0) krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van LG LF300CP(LP-C303R20), LF480CE(LP-C483TA0) bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de LG LF300CP(LP-C303R20), LF480CE(LP-C483TA0) kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met LG LF300CP(LP-C303R20), LF480CE(LP-C483TA0) . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.