Gebruiksaanwijzing /service van het product LWJ0561ACG van de fabrikant LG
Ga naar pagina of 23
Room Air Conditioner SER VICE MANU AL MODEL: L WJ0561A CG L WJ0561 A CP /AAG CA UTION - BEFORE SER VICING THE UNIT , READ THE "SAFETY PRECA UTIONS" IN THIS MANU AL. - ONL Y FOR A UTHORIZED SER VICE PERSONNEL. WEBSITE http://biz.LGservice.com E-MAIL http://www .
—2— CONTENTS 1. PREF A CE .................................................................................................................................................. 3 1.1 FEA TURES ..........................................................
—3— 1. PREF A CE This ser vice manual provides v arious ser vice information, including the mechanical and electrical par ts , etc. This room air conditioner was man ufactured and assemb led under a strict quality control system. The refrigerant is charged at the f actor y .
—4— 1.3 LOCA TIONS OF CONTROLS 1.4 SAFETY PRECA UTIONS 1. When ser vicing, set the RO T AR Y SWITCH to Off ( 0 ) and unplug the power cord. 2. Obser ve the original lead dress. If a shor t circuit is found, replace all parts which hav e been ov erheated or damaged by the short cir- cuit.
— 5 — 2. DISASSEMBL Y INSTR UCTIONS 2.1 MECHANICAL P ARTS 2.1.1 FRONT GRILLE 1. Disconnect the unit from the power source . 2. Remov e the two knobs b y pulling them off. Using a screwdriv er , remov e the screw that secures the front grille to control board.
— 6 — 2.2 AIR HANDLING P ARTS 2.2.1 AIR GUIDE UPPER 1. Disconnect the unit from the power source . 2. Remov e the front grille. (Ref er to Section 2.1.1) 3. Remov e the cabinet. (Ref er to Section 2.1.2) 4. Remov e the control board. (Ref er to Section 2.
— 7 — 2.2.3 MO T OR 1. Disconnect the unit from the pow er source. 2. Remov e the front grille. (Ref er to Section 2.1.1) 3. Remov e the cabinet. (Ref er to Section 2.1.2) 4. Remov e the control board. (Ref er to Section 2.1.3) 5. Remov e the air guide upper .
— 8 — 2.3.3 CAP A CITOR 1. Remov e the cabinet. (Ref er to Section 2.1.2) 2. Remov e the control board. (Ref er to Section 2.1.3) 3. Discharge the capacitor by placing a 20 K Ω resistor across the capacitor ter minals. 4. Remov e the screw which f astens the capacitor clamp .
2.4.2 EV APORA T OR 1. Remov e the cabinet. (Ref er to section 2.1.2) 2. Discharge the refrigerant by using a refrigerant recov er y system. 3. Remov e the air guide upper . (Ref er to Section 2.2.1) 4. After discharging the refrigerant completely , unbraze the interconnecting tube at the e vaporator connections.
— 10 — Equipment needed: V acuum pump , charging cylinder , manifold gauge , brazing equipment, pinch-off tool capab le of making a vapor proof seal, leak detector , tubing cutter , hand tools to remove components and service valv e.
— 11 — 3. INST ALLA TION This air conditioner is designed with a button- down chassis so that it can be installed simply in a window . 3-1. SELECT THE BEST LOCA TION 1. T o pre vent vibr ation and noise, mak e sure the unit is installed securely and firmly .
— 12 — 3.4 HO W T O INST ALL • WHEN USING GASKET 2 1 2 F E C 3 G A B RIGHT SIDE HORIZONTAL LINE D 1. WINDO W (A - WIDTH ,B-H EIGHT) 2. GASKET 3. W ALL AB C D E F G 487mm 324mm 30mm 0~25mm O VER .
— 13 — 4.2 PIPING SYSTEM F ollowing is a brief descr iption of the impor tant components and their function in what is called the refrigeration system. Ref erence should be made to Figure 26 to follo w the refrigerating cycle and the flow of the refrigerant in the cooling cycle.
— 14 — 4.3 TR OUBLESHOO TING GUIDE In general, possib le trouble is classified in two kinds . The one is called Starting Failure which is caused from an electrical defect. The other is Ineff ective Air Conditioning caused from a def ect in the refrigeration circuit and improper application.
— 15 — Fails to Start Improper thermostat setting Loose terminal connection Improper wiring Check of po wer source. Drop of power voltage . Capacitor check. Replacement. Check of control s witch setting. Compressor f ails only to star t. Def ect of compressor capacitor .
— 16 — ROOM AIR CONDITIONER V OL T A GE LIMITS NAME PLA TE RA TING MINIMUM MAXIMUM 220V~240V 198V 264V COMPLAINT CA USE REMED Y F an motor will not run. No power Check v oltage at outlet. Correct if none. P ow er supply cord Check v oltage to rotar y s witch.
— 17 — COMPLAINT CA USE REMED Y F an motor noise. F an If crac ked, out of balance, or partially missing, replace it. Blower If crac ked, out of balance, or partially missing, replace it. Loose set screw Tighten it. W or n bear ings If knocking sounds contin ue when running or loose, replace the motor .
— 18 — COMPLAINT CA USE REMED Y Compressor cycles on F an motor If not r unning, deter mine the cause. Replace if ov erload required. Condenser air flow Remov e the cabinet, inspect the interior surface restriction of the condenser . If restricted, clean carefully with a vacuum cleaner (do not damage fins) or brush.
5. SCHEMA TIC DIA GRAM — 19 — 5-1. CIRCUIT DIA GRAM • MODEL : L WJ0561A CG MOTOR C F H 7 8 6 4 2 1 5 3 H L M POWER INPUT ROTARY SWITCH THERMOSTAT BR BK RD BK RD OR(BR) YL BK(BR) (Plain) WH(BL) (Ribbed) GN(GN/YL) COMP.
— 20 — • MODEL : L WJ0561A CP/AA G DESCRIPTION & NAME P O W E RC O R DA S S Y FA N M OT O R COMPRESSOR ROT ARY SWI T C H THERMOST A T CAP A CIT OR O VERLO AD PRO TECT OR Q'TY 1 1 1 1 1 1 1 REF .
— 21 — 6. EXPLODED VIEW 152302 135313 352390 159900-2 145200 159900-1 130410 359012 W48602 135312 149410 354210 349480 352380 149980 559011 346811 554030 266003 264110 269310 W0CZZ 249950 135510 5.
— 22 — 7. SER VICE P AR TS LIST 130410 BASE ASSEMBL Y , SINGLE 3041A10011G 3041A10011G 3041A10011G R 130910 CABINET ASSEMBL Y , SINGLE 3091A10020B 3091A10020B 3091A10020B R 135312 GRILLE ASSEMBL Y.
P/NO:3828A20118B April, 2002 Printed in Korea.
Een belangrijk punt na aankoop van elk apparaat LG LWJ0561ACG (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen LG LWJ0561ACG heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens LG LWJ0561ACG vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding LG LWJ0561ACG leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over LG LWJ0561ACG krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van LG LWJ0561ACG bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de LG LWJ0561ACG kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met LG LWJ0561ACG . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.