NL
Lightolier logo
Officiële handleiding

Lightolier C7E170HW

2 pagina's·123 KB·Werklamp·PDF·EN
Lightolier C7E170HW
Inhoudsopgave 8 secties Calculite ® HID Downlight C7E170HW · Reflector Trim Frame-In Kit Lamp (Coated, Ceramic MH) · Electrical(cont.) · Job Information Type: · … TonenVerbergen
Page 1 of the Lightolier C7E170HW user manual — Job Information Type:
Pagina 1 · klik om te vergroten
Pagina 1

Calculite ® HID Downlight C7E170HW

Page 1 of 2 7" Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam

20" (508 mm) to 30" (762 mm) 9-3/4" (248 mm)

8 1 5 3 9 7 2 6 4 8

Top View (Magnetic Ballast)

Vertical Adjustment5/8" (16 mm) to 2 7/8" (73 mm)

20" (508 mm) to 30" (762 mm)

11" (280 mm) (100/150W)

Top View (Electronic Ballast)

2" (50 mm) max. Ceiling Thickness 7-3/8" (187 mm) Dia.

8-5/8" (200 mm) Dia.

Ceiling Cutout: 8" (203 mm) Dia.

Reflector Trim Frame-In Kit Lamp (Coated, Ceramic MH)

C7E17OHW CLW Specular Clear, White Painted Flange. C770MHOE1 Electronic 120V C770MHOE2 Electronic 277V 70W E17, ED17, BD17, (Open Rated) CLP Specular Clear, Matching Flange. C710MHOE1 Electronic 120V C710MHOE2 Electronic 277V 100W E17, ED17, BD17, (Open Rated) CCDW Comfort Clear Diffuse, White Painted Flange. C715MHOE1 Electronic 120V C715MHOE2 Electronic 277V 150W E17, ED17, BD17, (Open Rated) CCDP Comfort Clear Diffuse, Matching Flange. C770MHOU Magnetic 120V/277V 70W E17, ED17, BD17, (Open Rated) CCZW Champagne Bronze, White Painted Flange. C710MHOU Magnetic 120V/277V 100W E17, ED17, BD17, (Open Rated) CCZP Champagne Bronze, Matching Flange. C715MHOU Magnetic 120V/277V 150W E17, ED17, BD17, Open Rated)

Features 1. Reflector: Clear anodized aluminum, 0.040" (16-ga.). Provides wide beam distribution. Provides 50° visual cut-off to lamp and lamp image; self-flange in painted white or aperture-matching polished flange. Consult factory for other finishes. 2. Socket Housing: Galvanized steel, pre-wired with medium base pulse rated socket. Snaps onto upper reflector for secure attachment without tools; unitized construction assures proper lamp alignment to optics for consistent performance. 3. Mounting Frame: 0.048" (18-ga.) galvanized steel includes pre-installed mounting bars. 4. Mounting Ring: 0.048" (18-ga.) galvanized steel. Designed for vertical adjustment from above or below for ceilings from 0" to 2" thick. Center-line notches allow consistent alignment of multiple fixtures. 5. Retention Springs: Rust resistant springs secure cone in place for quick, tool-less installation. 6. Frame Vertical Adjustment Mechanism: Vertical adjustment mechanism accommodates mounting to virtually any ceiling system using pre-installed mounting bars, or 1/2" EMT tubing (by others). Single locking feature secures all adjustments. Alignment holes and markings allow fixture to be pre-set prior to installation. 7. Mounting Bars: 0.048" (18-ga.) Pre-installed, telescoping bars extend to 30" long and lock securely into position. Built-in locking tabs provide positive attachment to common T-bar systems. Self-centering feature simplifies installation in 24" O.C. grid systems. Attaches to steel or wood joists without accessories. 8. Ballast: Electronic 120V or 277V. Magnetic dual voltage (120V & 277V). Accessible from below for inspection and/or replacement without tools. 9. Junction Box: 0.048" (18-ga.) galvanized steel. UL listed for 8 No. 12 AWG, 90°C through branch circuit conductors; allows inspection from below. 10.Thermal Protector: (Not Shown) Meets NEC and UL requirements. Do not install insulation above nor within 3" (76mm) of any part of the luminaire.

Electrical(cont.)

Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M139 120/277 0.67/0.29 78 100W MH M90/M140 120/277 0.90/0.43 110 150W MH M102 120/277 1.40/0.61 167 Magnetic Ballast: 120/277V dual voltage, 60 Hz., encased and potted, HX-HPF

circuit type, high power factor, sound rating "B", -20°F minimum starting temperature, Type 1 Outdoor rating. Ballast ANSI Code Voltage Max. Amps Input Watts 70W MH M98/M143 120/277 1.90/0.80 94 100W MH M90/M140 120/277 2.40/1.10 125 150W MH M102 120/277 3.70/1.60 180 Options and Accessories Auxiliary: Add suffix A to Frame-In Kit and Reflector Trim. c ”A“. Emergency Lamp: Add suffix E to Reflector Trim and Frame-In Kit. See Spec. Sheet “A/E”. Slope Ceiling Adapters: See Specification Sheet SCA. Chicago Plenum: Consult Factory. Fuse: (Magnetic Ballast): Add suffix F1 or F2 to Frame in Kit (F1=120V, F2=277V).

Labels UL (Suitable for Damp Locations), CSA, I.B.E.W. For 150W, install fixtures with minimum spacing: 3 feet from center-to-center of adjacent luminaries; 3 inch from top of luminaire to overhead building member;1 1/2 feet from luminaire center to side building member.

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Electrical Electronic Ballast: 120V or 277V, 50/60 Hz., encased, high-power factor, T.H.D.

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • A0504
Show 9 more labels / short text on this page
(276 mm · 8-1/4" (210 mm) · 10-1/2" (267 mm) · 18-5/8" (473 mm) · 10-7/8" (276 mm) · 8-1/2" (216 mm) · 9-3/4" (248 mm) · 11-1/2" (292 mm) · 10-7/8" (276 mm)
Page 2 of the Lightolier C7E170HW user manual — Job Information Type:
Pagina 2 · klik om te vergroten
Pagina 2

8 Calculite ® HID Downlight C7E170HW

Page 2 of 2 7" Aperture, ED17 (Open Rated), Ceramic Metal Halide, Wide Beam

LUMINANCE SUMMARY - CD. / SQ. M.

Coefficients of Utilization

ANGLE 0 Deg. 45 Deg. 90 Deg. 45 11611 17393 23922 55 306 466 466 65 0 71 57 75 0 23 0 85 0 0 0

CEILING 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance = 20%

RCR

0 .72 .70 .70 .67 .67 .64 .64 .60 1 .68 .67 .66 .64 .66 .63 .63 .61 .61 .59 .57 2 .65 .63 .61 .59 .62 .58 .60 .57 .58 .56 .54 3 .62 .59 .56 .54 .58 .54 .57 .53 .55 .52 .50 4 .60 .56 .52 .50 .55 .50 .54 .49 .52 .49 .47 5 .57 .52 .49 .46 .51 .46 .50 .46 .49 .45 .44 6 .54 .49 .46 .43 .48 .43 .48 .43 .47 .42 .41 7 .51 .46 .42 .40 .45 .40 .45 .40 .44 .39 .38 8 .48 .43 .39 .37 .42 .37 .42 .37 .41 .36 .36 9 .46 .40 .36 .34 .40 .34 .39 .34 .39 .34 .33 10 .43 .37 .34 .31 .37 .31 .36 .31 .36 .31 .30 LUMINAIRE INPUT WATTS = 78.0

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 2050 35.98 59.89 0-40 3062 53.73 89.44 0-60 3423 60.05 99.96 0-90 3424 60.08 100 40-90 361 6.34 10.56 60-90 1 0.02 0.04 90-180-180 3424 60.08 100

** EFFICIENCY = 60.1% ** CERTIFIED TEST REPORT NO. 2418FR, DATE: FEB 10, 2004 SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**

LUMINANCE SUMMARY - CD. / SQ. M. ANGLE 0 Deg. 45 Deg. 90 Deg. 45 24858 30607 28891 55 1140 1179 1075 65 422 611 376 75 153 153 0 85 0 0 0

Coefficients of Utilization

CEILING 80% 70% 50% 30%

70 50 30 1050 1050 1050 10 Zonal Cavity Method- Effective Floor Cavity Reflectance = 20%

RCR

0 .74 .72 .72 .69 .69 .66 .66 .62 1 .71 .69 .68 .67 .68 .66 .65 .64 .63 .62 .59 2 .68 .65 .63 .61 .64 .60 .62 .59 .60 .58 .56 3 .65 .61 .58 .56 .60 .56 .59 .55 .57 .54 .52 4 .62 .58 .55 .52 .57 .52 .56 .51 .55 .51 .49 5 .59 .54 .51 .48 .54 .48 .53 .48 .52 .47 .46 6 .56 .51 .48 .45 .51 .45 .50 .45 .49 .45 .43 7 .53 .48 .45 .42 .48 .42 .47 .42 .46 .41 .40 8 .51 .45 .42 .39 .45 .39 .44 .39 .43 .39 .38 9 .48 .42 .39 .36 .42 .36 .41 .36 .41 .36 .35 10 .45 .40 .36 .34 .39 .34 .39 .33 .38 .33 .32 LUMINAIRE INPUT WATTS = 110

ZONAL LUMENS AND PERCENTAGES ZONE LUMENS % LAMP %LUMINAIRE 0-30 3282 38.62 62.14 0-40 4720 55.54 89.35 0-60 5275 62.07 99.86 0-90 5283 62.15 100 40-90 562 6.62 10.65 60-90 7 0.08 0.14 90-180-180 5283 62.15 100

** EFFICIENCY = 62.2% ** CERTIFIED TEST REPORT NO. 2267FR , DATE: JUN 23, 2003 SC = 1.1 COMPUTED BY LSI PROGRAM **TEST-LITE**

Job Information Type:

  • Lightolier a Genlyte Thomas Company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2004 Genlyte Thomas Group LLC (Lightolier Division)
  • A0504
Show 12 more labels / short text on this page
60° · 1,500 · 2,250 · 3,000 · 30° · 1,250 · 60° · 2,500 · 3,750 · 45° · 5,000 · 30°
Bronnen

Referenties en links

Pagina's waarnaar wordt verwezen in deze handleiding — fabrikant, ondersteuning en downloads.

Vraag stellen over de Lightolier C7E170HW

Eigenaren en ons team reageren doorgaans binnen een dag — en uw vraag helpt ook de volgende persoon.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Nog geen vragen over de Lightolier C7E170HW

Stel als eerste een vraag — andere eigenaren of ons team geven antwoord.

Origineel document

Lightolier C7E170HW handleiding-pdf

2 pagina's·123 KB·Werklamp·PDF
Klik op een bovenstaande pagina om deze hier te openen
Pagina 1 / …
100%
Pagina's laden…