1450DomExptSvc REV: 9/25/08 SER VICE MANUAL (DOMESTIC AND INTERNATIONAL) IMPINGER CONVEYOR OVENS MODEL 1400 SERIES ADV ANT AGE Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Phone : (800) 374-3004 U.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 2 T ABLE OF CONTENTS TABLE OF CONTENTS ...........................................................................................................................................
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 3 SEQUENCE OF OPERATION MODEL 1450 / 120 VAC / 60 HZ / NATURAL GAS MODEL 1451 / 120 VAC / 60 HZ / LP GAS MODEL 1480 / 120 VAC / 60 HZ / TOWN GAS POWER SUPPLY Electrical power is supplied to the oven by a three-co nductor cordset.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 4 energized, the normally open cont act s cl ose, energizing the main fan motor and coolin g fan. Closing the main fan switch also su pp lies po wer to the conveyor control and the centrifugal switch of the main fan motor.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 5 SEQUENCE OF OPERATIONS MODEL 1456 / 220-240 VAC / 50 HZ / NATURAL G AS MODEL 1457 / 220-240 VAC / 50 HZ / L.P. GAS MODEL 1474 / 220-240 VAC / 50 HZ / NATURAL G AS MODEL 1475 / 220-240 VAC / 50 HZ / L.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 6 SCHEMATIC 1450 / 1451 / 1480.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 7 SCHEMATIC 1452 / 1453.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 8 SCHEMATIC 1454 / 1455.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 9 SCHEMATIC 1456 / 1457.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 10 SCHEMATIC 1474 / 1475 / 1476.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 11 TROUBLESHOOTING GUIDE GAS OVENS IMPINGER ADVANTAGE SERIES SYMPTOM POSSIBLE CAUSE EVALUATION Incoming Power Supply Check breakers, reset if required. Call P owe r Co. if needed (Export Ovens) For some export ovens , there is a control circuit step- down transformer.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 12 Centrifugal Switch of Burner Blower Motor Check for 24 VAC output from seconda ry of transformer. If voltage is present, check for 24 VAC at pin 6 and ground on ignition control.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 13 Thermocouple Probe Remove thermocouple lea ds from the te mperature control board, and measure the millivolt output of these leads. Refer to charts on pa ge 25 in the adjustment section for proper readings.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 14 DC Motor Control Board Check for 120 VAC input to the control board at terminals L1 and L2. If not present, check the oven fan switch and wiring ba ck to 3 amp fuse and then back to power source if ne ce ssary.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 15 Gas Pressure Switch This switch is located inside the gas valv e and sh ould close when gas pressure is prese nt. WITH POWE R OFF: remove 3 prong plug (on gas valve ) and measure continuity between terminals 2 and 3.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 16 Flame Sensor To check for flame se nsor operation, co nnect a digital multimeter (capable of meas uring D.C. micro amps) between the flame sensor wi re a nd Ignition Control. Sensor current from sensor control is 3 micro amp s minimum.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 17 Thermocouple Probe Remove thermocouple lea ds from the te mperature control board and measure the millivolt output of these leads. Refer to chart on Page 25 for pr oper readings.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 18 TROUBLESHOOTING GUIDE ELECTRIC OVENS IMPINGER ADVANTAGE SERIES SYMPTOM POSSIBLE CAUSE EVALUATION Incoming Power Supply Check breakers/Reset if required. Call Power Co. if needed.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 19 Temperature Control Board Check for 12 0 VAC input to temperature control board. If not present, check wiring from Hi-Limit to temperature control board. Turn the tem peratu re adjustment dial to the maximum temperature position .
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 20 Conveyor Gear Motor If DC voltage is present A+ and A- and the motor does not run, first check the mini breaker and then the conveyor. Refer to the nex t possible cause. Ch eck motor brushes for excessive or abnorm al wear, replace as needed.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 21 REMOVAL INSTALLATION & ADJUSTM ENTS IMPINGER ADVANTAGE SERIES CAUTION! BEFORE REMOVING OR INSTALLING ANY COMPONENT IN THE IMPINGER OVEN BE SURE TO DISCONNECT ELECTRICAL POWER AND GAS SUPPLY MOTOR, MAIN FAN 1.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 22 CAPACITOR, MOTOR 1. Shut off power at main breaker. 2. Remove motor cover from back of oven. 3. Discharge capacitor. 4. Remove and replace. RELAY, D.P.S.T. 1. Shut off power at main breaker.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 23 B URNER BLOWER MOTOR - REPLACEMENT 1. Shut off power at main breaker. 2. Remove control panel top and fro nt cover. 3. Unplug motor connector. 4. Remove three (3) screws from blo wer tube at burner housing.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 24 FRONT VIEW MANIFOLD ADJUSTMENT SCREW LOCATED UNDER COVER SCREW TOP VIEW PILOT LINE CONNECTION MANIFOLD PRESSURE ADJUSTMENT CONNECTION MANIFOLD ADJUSTMENT SCREW LOCATED UNDE R COVER SCREW MANIFOLD PRESSURE - ADJUSTMENT 1.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 25 BURNER IGNITOR 1. Shut off power at main breaker. 2. Remove control panel top and fro nt cover. 3. Remove burner assemb ly. (SEE "BURNER ASSY.") 4. Remove pilot shield and pilot shield extensio n.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 26 BURNER CONTROL TRANSFORMER -REPLACE MENT 1. Shut power off at main breaker. 2. Remove control panel top and fro nt cover. 3. Remove two (2) wire s on primar y side, note color and location.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 27 HALL EFFECT SENSOR - REPLACEMENT 1. Shut off power at main breaker. 2. Remove control box cover. 3. Remove three- (3) wire co nnector from hall effect sensor board. 4. Remove two (2) screws fro m conveyor drive motor.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 28 THE FOLLOWING ITEMS ARE USED IN THE MODE L 1456, 1457, 1474, 147 5, 1476 IMPINGER OVENS AIR PRESSURE SWITCHES - REPL ACEMENT AND ADJUSTMENT 1. Remove control panel top. 2. Disconnect wires from switch ma king note of wire number and location for reinstallation.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 29 IGNITION CONTROL - REPLACEMENT 1. Remove control panel top and fro nt cover. 2. Depress two (2) locking clips on front cover of relay. 3. Remove control portion of relay by pulling straight out (rocking motion).
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 30 GENERAL – 1450 SERIES LETTER PART # DESCRIPTION A 369003 Door Hinge B 369110 Access Window Assy. C 369337 Retainer (Old Style) 369929 Retainer (New Style) D 369828 Handle, Spacer E 369209 Latch & Strike F 369310 Screw 6-32 x 3/16” G 369308 Access Window Assy.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 31 GENERAL - 1450 SERIES BLOW-UP.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 32 CONTROL BOX – 1450, 1451, 1480 LETTER PART # DESCRIPTION A 369012 Fuse Holder B 369014 Fuse, 1 0 AMP C 369013 Fuse, 3 AMP D 369872 Instruction Plate E 369805 Switch, On/Off F 369809 Conveyor Control Pot.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 33 CONTROL BOX – 1450, 1451, 1480 BLOW-UP.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 34 CONTROL BOX – 1452, 1453 LETTER PART # DESCRIPTION A 369129 Fuse Holder B 369166 Fuse, 1 0 AMP C 369013 Fuse, 3 AMP D 3690.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 35 CONTROL BOX – 1452, 1453 BLOW-UP.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 36 CONTOL BOX – 1454, 1455 LETTER PART # DESCRIPTION A 357107 Fuse Holder B 369014 Fuse, 10 AMP C 369013 Fuse, 3 AMP D 370137.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 37 CONTROL BOX – 1454, 1455 BLOW-UP.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 38 CONTROL BOX – 1456, 1457, 1474, 1475, 1476 LETTER PART # DESCRIPTION A 369378 Cooling Fan B 369809 Conveyo r Control Pot.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 39 CONTROL BOX – 1456, 1457, 1474, 1475, 1476 BLOW-UP.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 40 OVEN BACK, GAS – ELECTRIC LETTER PART # DESCRIPTION A 369808 Cover, Moto r (Gas Ovens) 370140 Cover, Motor (Electri c Ove ns) B 369800 Motor, Main Fan (60 Hz) 369214 Motor, Main Fan (50 Hz) C 369033 Motor Clamp D 369215 Motor Support Assy.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 41 OVEN BACK, GAS – ELECTRIC BLOW-UP.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 42 CONVEYOR – 1450 SERIES LETTER PART # DESCRIPTION 369830 Complete Conveyor A 369816 Conveyor Belting 370092 Conveyor Beltin.
Impinger I – 1400 Series Advantage Service Manu al – Dom & Int’l 43 CONVEYOR 1450 SERIES BLOW-UP.
Impinger I – 1400 Series Advantage Service Manu al - Dom & Int’l 44 Lincoln Foodservice Products, LLC 1111 North Hadley Road Fort Wayne, Indiana 46804 United States of America Telephone: (260) 459-8200 U.S. Facsimile: (888) 790-8193 Int’l Facsimile: (260) 436-0735 Technical Service Hotline: (800) 678-9511 www.
Een belangrijk punt na aankoop van elk apparaat Lincoln 1400 Series (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln 1400 Series heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln 1400 Series vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln 1400 Series leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln 1400 Series krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln 1400 Series bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln 1400 Series kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln 1400 Series . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.