Gebruiksaanwijzing /service van het product IM575 van de fabrikant Lincoln Electric
Ga naar pagina of 28
MAS TER LOAD 750 OPERA TORS MANUAL IM575 May, 2006 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation ... and thought- ful operation on your part.
i i FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii ii WELDING EQUIPMENT SAFETY ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87.
iii iii FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
iv WELDING EQUIPMENT SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instruc- tions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suivantes: Sûreté Pour Soudage A L’Arc 1.
v LOAD BANK SAFETY v The load bank is an industrial test unit designed to be used indoors or outdoors (sheltered from moisture). However, because the nature of the load bank’s func- tion is the dissipation of electrical energy, electrical energy is transformed into heat by the resistor ele- ments.
vi MASTER LOAD 750 vi Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
MASTER LOAD 750 vii T ABLE OF CONTENTS DESCRIPTION TECHNICAL SPECIFICATIONS .........................................................................................1 SAFETY PRECAUTIONS .................................................................
1 MASTER LOAD 750 1 82 dBA at 3 ft DESCRIPTION TECHNICAL SPECIFICA TIONS – MASTER LOAD 750 INPUT – POWER LOAD CAP ABILITY PROTECTION FUSES COOLING BLOWER Height Width Depth 34.
GENERAL DESCRIPTION The Master Load 750 Load Bank is designed for elec- trically loading and testing power sources. The unit is designed for production line and job site use. The total loading capability of the Master Load 750 is in fixed steps of 25, 25, 50, 50, 100, 250, 250 Amps @ 50V AC or DC, totaling 750 Amps.
3 INST ALLA TION MASTER LOAD 750 3 BEFORE INST ALLA TION Inspect the Load Bank for obvious damage such as broken wires, broken or dented panels, cracked ceramic insulators, or any other component breakage that may have occurred in shipment.
4 OPERA TION 4 PURPOSE AND USE OF CONTROLS 1. POWER ON/OFF switch - Turns on cooling fan and powers remainder of control circuit. Red light shows POWER ON. 2 . BLOWER FAIL indicator - The purpose of the BLOWER FAIL lamp is to warn the operator and remove the load to the load bank in case of an air failure or improper cooling of the load elements.
5 MAINTENANCE 5 SAFETY PRECAUTIONS Before servicing, read and observe all safety precautions throughout this manual. ELECTRIC SHOCK can kill. • Only qualified personnel should perform this maintenance. • Turn the input supply power OFF at the disconnect switch or fuse box before working on this equipment.
6 TROUBLESHOOTING & REP AIR 6 MASTER LOAD 750 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
7 TROUBLESHOOTING & REP AIR 7 MASTER LOAD 750 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
8 TROUBLESHOOTING & REP AIR 8 MASTER LOAD 750 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
9 TROUBLESHOOTING & REP AIR 9 MASTER LOAD 750 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed.
10 DIAGRAMS 10 MASTER LOAD 750 D26300 3-5-97 MASTERLOAD 750 - WIRING DIAGRAM.
11 DIAGRAMS MASTER LOAD 750 11 SB2561 2-22-96 MASTERLOAD 750 - DIMENSION PRINT.
P ARTS MASTER LOAD 750 D26244 SHT 1 & 2 3-6-97 MASTERLOAD 750 - GENERAL ASSEMBL Y.
1 Base, Load Bank M18720 1 X 2 Side Panel, (Left) M18720-1 1 X 3 Side Panel, (Right) M18720-2 1 X 4 Venturi, Fan M18720-3 1 X 5 Rail (For Relay K8 Mtg.) M18720-62 1 X 6 Pan, Relay M18720-5 1 X 7 Panel, Screened M18720-6 2 X 8 Cover. Load Bank M18720-7 1 X 9 Cover.
49 Bushing, Seal M18720-44 1 X 50 Spring M18720-45 42 X 51 Switch, Temp {S11} M18720-46 1 X 52 - - 53 Nut Assembled Washer M18720-47 84 X 54 Threadlocker M18720-48 AR X 55 Stud M18720-49 4 X 56 - - 57 - - 58 Semiconductor, Rectifier {CR1} M18720-52 1 X 59 - - 60 Shunt, 800A.
NOTES.
NOTES.
NOTES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TENÇÃO Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Een belangrijk punt na aankoop van elk apparaat Lincoln Electric IM575 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln Electric IM575 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln Electric IM575 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln Electric IM575 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln Electric IM575 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln Electric IM575 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln Electric IM575 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln Electric IM575 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.