Gebruiksaanwijzing /service van het product IM819-B van de fabrikant Lincoln Electric
Ga naar pagina of 37
RANGER ™ 10,000 OPERA TOR’S MANUAL For Machines with Code Number 11041, 11095, 11151, 11253 IM819-B September, 2006 Safety Depends on You Lincoln arc welding and cutting equipment is designed and built with safety in mind. However, your overall safety can be increased by proper installation .
FOR ENGINE powered equipment. 1.a. Turn the engine off before troubleshooting and maintenance work unless the maintenance work requires it to be running. ____________________________________________________ 1.b. Operate engines in open, well-ventilated areas or vent the engine exhaust fumes outdoors.
ii SAFETY ii ARC RA YS can burn. 4.a. Use a shield with the proper filter and cover plates to protect your eyes from sparks and the rays of the arc when welding or observing open arc welding. Headshield and filter lens should conform to ANSI Z87. I standards.
FOR ELECTRICALL Y powered equipment. 8.a. Turn off input power using the disconnect switch at the fuse box before working on the equipment. 8.b. Install equipment in accordance with the U.S. National Electrical Code, all local codes and the manufacturer’s recommendations.
Mar. ‘93 iv SAFETY iv PRÉCAUTIONS DE SÛRETÉ Pour votre propre protection lire et observer toutes les instructions et les précautions de sûreté specifiques qui parraissent dans ce manuel aussi bien que les précautions de sûreté générales suiv- antes: Sûreté Pour Soudage A L’Arc 1.
v v Thank You for selecting a QUALITY product by Lincoln Electric. We want you to take pride in operating this Lincoln Electric Company product ••• as much pride as we have in bringing this product to you! Read this Operators Manual completely before attempting to use this equipment.
vi vi T ABLE OF CONTENTS Page Installation ................................................................................................................... ....Section A Technical Specifications .....................................................
A-1 INST ALLA TION RANGER 10,000 A-1 TECHNICAL SPECIFICA TIONS - Ranger 10,000 (K1419-4 ), (K2160-3 ) and (K2468-1) INPUT - GASOLINE ENGINE RA TED OUTPUT @ 104°F (40°C)- WELDER HEIGHT WIDTH DEPTH WEIGHT 30.3 in. 19.1 in. 42.0 in. 502 lbs. (228kg) K1419-4 770 mm 485 mm 1067 mm 505 lbs.
A-2 INST ALLA TION RANGER 10,000 A-2 SAFETY PRECAUTIONS MACHINE GROUNDING Because this portable engine driven welder or genera- tor creates it’s own power, it is not necessary to con- nect it’s frame to an earth ground, unless the machine is connected to premises wiring (your home, shop, etc.
FUEL Fill the fuel tank with clean, fresh, lead-free gasoline. Observe fuel gauge while filling to prevent overfilling. OIL The Ranger 10,000 is shipped with the engine crankcase filled with SAE 10W-30 oil. Check the oil level before starting the engine.
A-4 INST ALLA TION RANGER 10,000 A-4 WELDING OUTPUT CABLES With the engine off, connect the electrode and work cables to the studs provided. These connections should be checked periodically and tightened if neces- sary. Loose connections will result in overheating of the output studs.
A-5 INST ALLA TION RANGER 10,000 A-5 LOCA TION / VENTILA TION The welder should be located to provide an unrestrict- ed flow of clean, cool air to the cooling air inlets and to avoid heated air coming out of the welder recirculating back to the cooling air inlet.
A-6 INST ALLA TION RANGER 10,000 A-6 120 V DUPLEX RECEPTACLES The 120V auxiliary power receptacles should only be used with three wire grounded type plugs or approved double insulated tools with two wire plugs. The current rating of any plug used with the system must be at least equal to the current load through the associated receptacle.
A-7 INST ALLA TION RANGER 10,000 A-7 TABLE lll ELECTRICAL DEVICE USE WITH THE RANGER 10,000. Type Common Electrical Devices Possible Concerns Resistive Heaters, toasters, incandescent NONE light bulbs, electric range, hot pan, skillet, coffee maker.
A-8 INST ALLA TION RANGER 10,000 A-8 STANDBY POWER CONNECTIONS The RANGER 10,000 is suitable for temporary, stand- by, or emergency power using the engine manufactur- er ’ s recommended maintenance schedule. The RANGER 10,000 can be permanently installed as a standby power unit for 240V-3 wire, single phase 38 ampere service.
240 Volt 60 Hz. 3-Wire Service POWER COMPANY METER 240 VOLT 120 VOLT 120 VOLT LOAD N NEUTRAL BUS GROUND PREMISES DISCONNECT AND SERVICE OVERCURRENT PROTECTION GND N NOTE: No. 6 COPPER CONDUCTOR CABLE SEE NATIONAL ELECTRICAL CODE FOR ALTERNATE WIRE SIZE RECOMMENDATIONS.
WELDER CONTROLS - FUNCTION AND OPERA TION ENGINE SWITCH The engine switch is used to Start the Engine, Select High Idle or Auto Idle while the engine is running, and stop the Engine. When placed in the “ OFF ” position, the ignition circuit is de-energized to shut down the engine.
“ RANGE ” SWITCH The “ Range ” switch is used to select one of three amperage ranges with generous overlap for Stick/TIG welding, or one Wire Feed welding range. Never change the “ RANGE ” Switch setting while welding. This will damage the switch.
B-3 OPERA TION B-3 ST ARTING/SHUTDOWN INSTRUCTIONS STARTING THE ENGINE Be sure all Pre-Operation Maintenance has been per- formed. Also, read the Engine Owner ’ s Manual before starting for the first time. Remove all loads connected to the AC power recepta- cles.
B-4 OPERA TION B-4 WELDING PROCESS For any electrodes the procedures should be kept within the rating of the machine. For electrode infor- mation see the appropriate Lincoln publication. STICK (CONSTANT CURRENT) WELDING Connect welding cables to the "TO WORK ” and "ELECTRODE ” studs.
B-5 OPERA TION B-5 RANGER 10,000 SUMMARY OF WELDING PROCESSES CONTROL ELECTRODE CABLE IDLE WHEN NOT TO START PROCESS USED MODE WELDING WELDING STICK No AUTO Hot Touch electrode to work. Welding starts immediately and engine goes to high idle. WIRE FEED, LN-25 WITH No AUTO Cold Press gun trigger, LN-25 INTERNAL CONTACTOR contactor closes.
C-1 ACCESSORIES C-1 RANGER 10,000 OPTIONAL EQUIPMENT (Field Installed) K957-1 HEAVY DUTY, TWO WHEEL TRAILER FOR SMALL WELDERS - For road, off-road and in-plant and yard towing. (For highway use, consult applicable federal, state and local laws regarding requirements for brakes, lights, fenders, etc.
C-2 ACCESSORIES C-2 RANGER 10,000 RECOMMENDED EQUIPMENT STICK K704 Accessory Kit - For Stick Welding. Includes 35 ft (10.7m). • 2/0 AWG electrode cable, 30 ft. (9.1m) • 2/0 AWG work cable with lugs, headshield, filter plate, work clamp, and electrode holder.
Have qualified personnel do the maintenance work. Turn the engine off before working inside the machine. In some cases, it may be necessary to remove safety guards to perform required maintenance. Remove guards only when necessary and replace them when the mainte- nance requiring their removal is complete.
D-2 MAINTENANCE D-2 Use 4-stroke motor oil that meets or exceeds the requirements for API service classification SG or SH. Always check the API SERVICE label on the oil con- tainer to be sure it includes the letters SG or SH. SAE 10W-30 is recommended for general, all-tempera- ture use, -5 F to 104 F (-20 C to 40 C).
D-3 MAINTENANCE D-3 ENGINE ADJUSTMENTS OVERSPEED IS HAZARDOUS The maximum allowable high idle speed for this machine is 3750 RPM, no load. Do NOT tamper with governor components or setting or make any other adjustments to increase the maximum speed. Severe personal injury and damage to the machine can result if operated at speeds above maximum.
E-1 TROUBLESHOOTING E-1 RANGER 10,000 If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-2 TROUBLESHOOTING E-2 RANGER 10,000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
E-3 TROUBLESHOOTING E-3 RANGER 10,000 Observe all Safety Guidelines detailed throughout this manual If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
STARTER CR1 STARTER SOLENOID 12 VOLT IDLER SOLENOID BATTERY AC AC B+ SWITCH REGULATOR FLYWHEEL ALTERNATO R B- HOUR METER 5E 5D 224 ENGINE COMPONENTS 224A 1 2 3 CONNECTOR PIN NU MBERS: 7 6 12 1 2 3 4 J1 N.A. B J2 SOLENOID FUEL SHUTOFF OIL PRESSURE TERMINAL BLOCK (SEE CONN.
F-2 DIAGRAMS F-2 RANGER 10,000 IDLER SOLENOID HOUR METER 5E 5D 224 1 2 3 CONNECTOR PIN NU MBERS: 7 6 12 1 2 3 4 J1 J2 209A M20301 215 + ELECTRIC AL SYMBOL S PER E1537 STATOR REACTOR S1 WO RK ELECTRODE.
F-3 DIAGRAMS F-3 RANGER 10,000 CR1 STARTER SOLENOID AC AC B+ REGULATOR FLYWHEEL ALTERNATOR B- 5E 5D 224 ENGINE COMPONENTS 224A 1 2 3 CONNECTOR PIN NUMBERS: 7 6 12 1 2 3 4 J1 J2 209A 209A 224C 210 GENE.
F-4 DIAGRAMS F-4 RANGER 10,000 RANGER 10,000 RANGER 10,000 / / L L N -15 AND LN-25 ACROSS T AND LN-25 ACROSS T H E ARC CONNECT E ARC CONNECT IO N DI N DI AG RA M ELECTRIC SHOCK can kill Do not operate with panels open. Disconnect NEGATIVE (-) Battery lead before servicing.
F-5 DIAGRAMS F-5 RANGER 10,000 M2 02 67 A. A. 0 1 26.5 9 30.2 7 9.09 9.09 17.0 0 21.2 2 8.80 30.0 0 42.0 0 22.1 5 10.3 3 CE NTER OF GR AVITY WITH O IL IN ENG INE AN D FULL FU EL T AN K 9.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic READ AND UNDERST AND THE MANUF ACTURER’S INSTRUCTION FOR THIS EQUIPMENT AND THE CONSUMABLES TO BE USED AND FOLLOW YOUR EMPLOYER’S SAFETY PRACTICES.
W ARNING A VISO DE PRECAUCION A TTENTION W ARNUNG A TEN ÇÃ O Spanish French German Portuguese Japanese Chinese Korean Arabic LEIA E COMPREENDA AS INSTRUÇÕES DO F ABRICANTE PARA ESTE EQUIP AMENTO E AS P ARTES DE USO, E SIGA AS PRÁTICAS DE SEGURANÇA DO EMPREGADOR.
• Sales and Service through Subsidiaries and Distributors Worldwide • Cleveland, Ohio 44117-1199 U.S.A. TEL: 216.481.8100 FAX: 216.486.1751 WEB SITE: www.
Een belangrijk punt na aankoop van elk apparaat Lincoln Electric IM819-B (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lincoln Electric IM819-B heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lincoln Electric IM819-B vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lincoln Electric IM819-B leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lincoln Electric IM819-B krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lincoln Electric IM819-B bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lincoln Electric IM819-B kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lincoln Electric IM819-B . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.