Gebruiksaanwijzing /service van het product 32530 van de fabrikant Lindy
Ga naar pagina of 40
© LINDY ELECTRONICS LIMITED & LINDY-ELEKTRONIK GMBH - FIRST EDITION (NOV 2007) U8/16-Mo dular KV M Switch with modu les: Cat.5 Ext ender an d IP Acce ss Modules User Manual English LINDY No.
2 Contents Section 1 .................................................................................. 3 1.1 About the U 8/16 concept ................................................................... 4 1.2 U8/16-Modu lar IP Access module: U8/16-IP .
Section 1 Introducing the U8/16-IP 4 1.1. About the U8/16 concept The U8/16 series KVM switch supports traditional PS/2 mouse and keyboard connections as well as modern USB connections. The U8/16 series supports the following computer platforms, PC, Mac and SUN.
Section 1 Introducing the U8/16-IP 6 1.5. Product Features 8/16 port KVM switch in a 1U, 19” rackmount size design Built-in daisy chain port allows daisy chaining of up to 8 LINDY KVM switches U or P series to be connected to support up to 128 computers Local console operation plus optional KVM over IP or KVM over Cat.
8 Section 2 Hardware Installation Section 2 Hardware Installation 9 2.1. Product Information & Connection Guide Make your connections to the switch as detailed below. Ensure all devices are switched of f before connecting. Once all connections have been made, power on the switch, your monitor, and then the connected computers in that order.
Section 2 Hardware Installation 10 2.2. Rackmount Installation Before you start installation please verify that all parts are included according to the package contents. If you want to install the KVM Switch in a 19” server rack please attach the enclosed 19” rackmount brackets using the screws provided.
12 Section 3 KVM Switch Operation Section 3 KVM Switch Operation 13 3.1. KVM Switch Operation 3.1.1. Password Security When you power on the U8/16 it will ask you for a user name and a password. The default user name and default password for both is eight zeros –“00000000” .
Section 3 KVM Switch Operation 14 3.1.3. Computer / Port Selecti on You can select the computer you want to access in one of three different ways: Front panel push button selection Keyboard hotkey selection On screen display menu selection 3.
Section 3 KVM Switch Operation 16 KVM Switch / Bank Selection: The U8/16 supports daisy chaining of up to 8 KVM Switches (Banks). Therefore, when using direct hotkey port selection you must include th.
Section 3 KVM Switch Operation 18 The OSD Menu displays further OSD configuration menus when selecting F1 from the main OSD menu. From the F1 Menu further submenus can be selected to configure the switch settings.
Section 4 CAT. 5 Extender Access & Operation 20 4.1. Cat.5 KVM Extender Features The modular KVM switch U8/16 offers the option to use it with or without a remote console access module. This module may either be a Cat.5 Extender or IP Access solution.
22 Section 5 IP Access Configuration & Operation Section 5 IP Access Configuration & Operation 23 5.0.1. KVM over IP Access Features The IP access module provides remote KVM over IP access to the KVM switch U8/16. It converts all keyboard video and mouse signals and sends them as TCP/IP signals over your LAN/WAN connection.
Section 5 IP Access Configuration & Operation 24 5.1. Configuration The U8/16-IP’s comm unication interfaces are all based on TCP/IP. The switch comes pre-configured with the following IP config.
Section 5 IP Access Configuration & Operation 26 Authentication To adjust the authentication settings, enter your login as a super user and change your password. Super user login Enter the login name of the super user . The initial value is "super" .
Section 5 IP Access Configuration & Operation 28 Host System Mouse Settings The host' s operating system obtains various settings from the mouse driver. Special Mouse Driver There are mouse drivers which influence the synchronization process and lead to desynchronized m ouse point ers.
Section 5 IP Access Configuration & Operation 30 5.4. Usage Prerequisites The U8/16-IP f eatures an embedded operating system offering a variety of standardized interfaces. This section wi ll describe t hese interfaces, and the way to use them in a more detailed manner.
Section 5 IP Access Configuration & Operation 32 5.6. Navigation Once logged into the U8/16-IP successfully, the main page appears. This page consists of three parts; each of them contains specific information. The buttons in the upper ar ea allow you to navigate within the front end.
Section 5 IP Access Configuration & Operation 34 Note: Your local keyboard changes its keyboard layout according to the remote host system. If you use a German administration system and your host system uses a US English k eyboard layout for instance, some special keys on the German keyboard will not work as expected.
Section 5 IP Access Configuration & Operation 36 Video Settings through the remote console: Brightness Controls the brightness of the picture Contrast Controls the contrast of the picture Clock Defines the horizontal frequency for a video line and depend s on the vi deo mode.
Section 5 IP Access Configuration & Operation 38 Remote Console Status Line Status line Shows both console and the connection st ate. The size of the remote screen is displayed. The example below was taken from a Remote Console with a resolution of 1024 x 768 pixels.
Section 5 IP Access Configuration & Operation 40 Telnet Console The U8/16-IP firmware features a Telnet server that enables a user to connect via a standard Telnet client .
Section 5 IP Access Configuration & Operation 42 5.7.2 . Virtual Media One of the computers connected to the U8/16-IP can also be set up for rem ote mass storage via a USB connection. Files can be uploaded t o the switch, which the host computer ‘sees’ as virtual drives.
Section 5 IP Access Configuration & Operation 44 Create a CD-ROM/ISO Image Follow t he procedure below to create a CD-ROM image which can be accessed by the host system via the U8/16-IP. The image file must be an ISO file format! First, on your client PC you must create an image of your CD which can be accessed by the host system.
Section 5 IP Access Configuration & Operation 46 7. You will see the dialog below detailing the active image: 8. Click Reactivate . Access the console window and you will see that another CD drive has been installed on the host computer. This is the virtual drive you have just set up.
Section 5 IP Access Configuration & Operation 48 2. Click on the Search for new devices icon - The U8/16-IP will be detected as an Unconfigured device and its MAC address will be displayed in the left panel. Double click on the MAC address to launch the Device Configuration Wizard .
Section 5 IP Access Configuration & Operation 50 5.7.3. User Management Change Password To change your password, enter the new password in the upper entry field.
Section 5 IP Access Configuration & Operation 52 5.7.4. KVM Settings User Console The following settings are user specific. This means the sup er user can customize these settings for individual users separately. Changing the settings for one user does not affect the settings for the other users.
Section 5 IP Access Configuration & Operation 54 Sun Microsystems Java Browser Plug-in Instructs the web browser of your administration system to use Sun’s JVM. The JVM in the browser is used to run the code for t he Remote Console window which is actually a Java Applet.
Section 5 IP Access Configuration & Operation 56 USB Mouse Type Enables USB mouse type. Choose between MS Windows 2000 or new er for MS Windows 2000 or Windows XP, or Other Operating Systems for MS Windows NT, Linux, or OS X. In MS Windows 2000 or newer mod e the remote mouse is always synchronized with the local mouse.
Section 5 IP Access Configuration & Operation 58 IP auto configuration With this option you can control if the U8/16-IP should obtain its network settings from a DHCP or BOOTP ser ver. For DHCP, select dhcp , and for BOOTP select bootp . If you choose none then IP auto configuration is disabled.
Section 5 IP Access Configuration & Operation 60 Note: The U8/16-IP has its own independent real time clock. Make sure the time setting of the U8/16-IP switch is correct. (See the Section called Date and Time on page 63) Enable Dynamic DNS Enables the Dynamic DNS service.
Section 5 IP Access Configuration & Operation 62 Certificate The U8/16-I P uses the Secure Socket Layer (SSL) protocol for any encrypted network traffic between itself and a connected client. During the conn ection establishment the U8/16-IP has to expose its identity to a client using a cryptographic certificate.
Section 5 IP Access Configuration & Operation 64 Confirm Challenge Password Confirmation of the Challenge Password Email The email address of a contact person that is responsible for the U8/16-IP and its security. Key length This is the length of t he generat ed key in bits.
Section 5 IP Access Configuration & Operation 66 Modem Init String The initialization string used by the U8/16-I P to initialize the modem. The default value will work with all modern standard modems directly connected to a t elephone line.
Section 5 IP Access Configuration & Operation 68 Event Log Important events like a login failure or a firmware update are logged to a selection o f logging destinations. Each of those events belongs to an event group, which can be activated separately.
Section 5 IP Access Configuration & Operation 70 5.7.6. Maintenance Device Information This section contains a summary showing various information about the U8/16-IP and its current firmware. It also allows you to reset the unit. View the data file for support Allows you to download the U8/16-IP data file with sp ecific support inform ation.
Section 5 IP Access Configuration & Operation 72 A new firmware update is a binary file w hich can be sent to you by email o r which you can download from our website www.lindy.com . Updating the firmware is a four stage process: 1. The new firmware file is uploaded to the U8/16-IP.
Troubleshooting 74 Troubleshooting If none of the LED displays on the KVM Switch are illuminated, please check that the power adapter is connected and switched on at the mains.
Technical Information 76 Key Codes This table shows the key codes used to defines k eystrokes or hotkeys for several functions. Please note that these key codes do not nec essarily re present key characters that are used on international keyboards. They name a key on a standard 104 key PC keyboard with US English language mapping.
Technical Information 78 Video Modes The table below lists the video modes that t he U8/16-IP remote console s upports. Please do not use any other custom video settings; the U8/16-IP may not be able to detect them.
Een belangrijk punt na aankoop van elk apparaat Lindy 32530 (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lindy 32530 heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lindy 32530 vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lindy 32530 leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lindy 32530 krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lindy 32530 bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lindy 32530 kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lindy 32530 . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.