LINDY CPU Switch Smart ENGLISH Quick In stallatio n and Operat ion G uide QUICK I NST ALLAT ION Pow er off all your com puters and connect them to the LIGHT GRE EN ports on the rear of the LINDY CPU Sw itch Sm art. LINDY 3-in-1 keyboard/vi deo/m ouse com binati on cables are recom m ended for conveni ence.
LINDY CPU Switch Smart GERMA N Kurzhandbuc h, E inführung FEAT URES Der L INDY CPU Switch SMART u nter st ü tzt M oni toraufl ö sungen bi s 1900x 1440 bis 75Hz sowie DDC Monitorerkennung. Der L I NDY CPU Sw i tch be n ö tigt bei Kabel l ä ngen unter 5m kei n Netztei l.
LINDY CPU Switch Smart GERMA N SPEZIELL E EIGENSCHA F T EN Der LINDY CPU Sw i tch SM ART ist Flash-uprgradable. Di e Firm ware ist dam it an zuk ü nftige neue Hardware prinzipi ell anpassbar.
LINDY CPU Switch Smart SPANI SH Gu í a r á pida de in stalaci ó n y funcionamiento INS T AL AC I Ó N R Á PIDA Desc onecte todos los ordenadores y con é ctelos a los puertos VERDE C LARO en la parte poster ior del LI NDY CPU Switc h Smart. Par a mayor comodidad s e recom iendan cables combi nados 3-en- 1 teclado/v í deo/rat ó n.
LINDY CPU Switch Smart FRENCH Guide d ’ installation r a pide et mode d ’ e mploi INST ALLAT ION RA PIDE Mettez tous vos ordinateurs hors tension et raccordez-l es aux ports VERT CLA IR à l'arri è re du LINDY C PU Sw itch Sm art. Les c â bles cl avie r/vi d é o/souri s Adder 3- in-1 sont recom m and é s pour des rai sons pratiques.
LINDY CPU Switch Smart ITALIA N Guida di installa zione rapida e funzionamento INST A L LAZIONE RAPI DA Spegnere tutti i computer e collegarl i al le porte VERDE CHIAR O sul retro del LI ND Y CP U Sw it ch S m a rt. Pe r f ac ilit à c ons iglia m o i ca vi L IN DY co m b ina ti 3- in- 1 tastiera/vi deo/m ouse.
LINDY CPU Switch Smart ITALIA N pres a a muro..
LI NDY C PU Switch Sm art I nstallation an d Use Page 1 A bout this manual LINDY CPU Sw itch Sm art - Installati on and Use Third edi tion (June 2001) (c) 2001 LINDY Electroni cs Ltd. Part No. LY 0039/3 www. l i n d y . c o m Part No. 32298 LINDY CPU Sw itch Sm art 2 Port Part No.
LI NDY C PU Switch Sm art I nstallation an d Use Page 2.
LI NDY C PU Switch Sm art I nstallation an d Use Page 3 Warran ty LINDY E lectroni cs Ltd warrants that this product shall be free from defects i n w orkm anship and materials for a peri od of one year from the date of ori ginal purchase.
LI NDY C PU Switch Sm art I nstallation an d Use Page 4 Radio Fre quency Ener gy Shiel ded cabl es m ust be used with this equipment to m ain tai n com pli ance with radio frequency energy em i ssi on regul ati ons and ensure a sui tably hi gh l evel of i mm unity to electrom agneti c disturbances.
LI NDY C PU Switch Sm art I nstallation an d Use Page 5 Contents 1. Introduction .................................................................................... 6 1.1 Key features ..................................................................
LI NDY C PU Switch Sm art I nstallation an d Use Page 6 appli cations .......................................................................................... 25 4. LINDY CPU Switch Smar t config uration option s ........................ 27 4.1 Screen saver time delay .
LI NDY C PU Switch Sm art I nstallation an d Use Page 7 1. Intr oduction Thank you for purchasing the LINDY CP U Sw itch Sm art. Your LINDY CPU S witch Sm art i s a high perform ance keyboard, m onitor and m ouse shari ng device which supports a w i de range of PC hardware and softw are pl atform s.
LI NDY C PU Switch Sm art I nstallation an d Use Page 8 Includes screen saver, auto-scan and vari able hotkey opti ons. Supports M i crosoft Inte lliM ou se , I nte lliM ou se E x plor er and other com m on wheel mi c e . Mouse restoration functions to enabl e ‘ hot pluggi ng ’ of certain systems.
LI NDY C PU Switch Sm art I nstallation an d Use Page 9 1.4 Pr oduct infor mation Figu re 1 - LI NDY CPU Switch Sm art fr ont v iew Figu re 2 - LI NDY CPU Switch Sm art rear v iew (4 port m odel) Figu.
LI NDY C PU Switch Sm art I nstallation an d Use Page 10 2. Installation 2.1 What y ou will need Cables to connect the LINDY CP U Sw itch Sm art to each of your PC keyboard, video and m ouse ports. Cabl e speci ficati ons are given i n appendix A. (Y ou do not need to connect a m ouse cabl e i f you are not usi ng the m ouse).
LI NDY C PU Switch Sm art I nstallation an d Use Page 11 2.2 M ounting the LIND Y CPU Switch S mar t The LINDY CPU Sw i tch Sm art has been designed for use on a desktop or shel f i n close proxim i ty to the user ’ s m oni tor and peripheral s.
LI NDY C PU Switch Sm art I nstallation an d Use Page 12 connected com puters. Fai l u re to switch the LINDY CP U Sw itch Sm art and com puters on i n the correct order can l ead to the mouse and/or keyboard not being recognised by the com puters when they are sw i tched on.
LI NDY C PU Switch Sm art I nstallation an d Use Page 13 keyboard cable and so w ill p ow er it se lf o n w hen the attached PC is switched on or w hen the opti onal power adapter is connected. Do not release the key unti l the LINDY CPU Switch Smart di spl ays ’ C ’ to show that i t has entered configure mode.
LI NDY C PU Switch Sm art I nstallation an d Use Page 14.
LI NDY C PU Switch Sm art I nstallation an d Use Page 15 L7 - Cascade query code = A D (default) L8 - Cascade query code = E F T1 - 2 seconds autoscan del ay tim e before switching to next port (defau.
LI NDY C PU Switch Sm art I nstallation an d Use Page 16 F1 - Displ ay firm ware first digi t (Note: F1 i s ) fol l o wed by NOT O ) F2 - Display fi rm w are second di git F3 - Displ ay firm ware .
LI NDY C PU Switch Sm art I nstallation an d Use Page 17 system which al l ows you to disconnect and re-connect the shared m ouse without pow eri ng dow n the system (although thi s is general ly not advisabl e) - see section 2.
LI NDY C PU Switch Sm art I nstallation an d Use Page 18 On m any PC s, m ous e m ove m ent w ill be lo st if th e P S/ 2 m ou se is unplugged and plugged back i n w hi lst the PC is runni ng. Mouse m ovem ent can then only be restored by rebooting the PC.
LI NDY C PU Switch Sm art I nstallation an d Use Page 19 ) I 4) Exit from confi gure m ode by typi ng ( I 5) Test the m ouse m ovem ent by m ovi ng the m ouse a short di stance. F5 - Restore PS /2 m ouse function F6 - R est ore In te lliMo us e f un ct ion 2.
LI NDY C PU Switch Sm art I nstallation an d Use Page 20 you m a y reset the LINDY CPU Sw i tch Sm art by powering off all the attached com puters and removing the optional pow er adapter. Step 4 - E nsur e that th e LI NDY C PU Switch Sm art is powered on Ensure that the LINDY CPU S witch Sm art is powered on.
LI NDY C PU Switch Sm art I nstallation an d Use Page 21 You m ay check the new firm ware version by enteri ng configure m ode and usi ng the firm ware version query function.
LI NDY C PU Switch Sm art I nstallation an d Use Page 22 Some u seful issues to bear in mi nd when perform ing flash upgr ades The upgrade program rewrites the LINDY CP U Sw i tch Sm art ’ s firm ware code. If the upgrade process is i nterrupted then the LINDY CPU S witch Sm art w ill h av e inv alid code and w ill not be a ble t o operate.
LI NDY C PU Switch Sm art I nstallation an d Use Page 23 3. Using the LINDY CPU Sw itch Smart This secti on ex pl ains the general operation of the LINDY CP U Sw itch Sm art. W e recom mend that you read this section before starti ng to use the product.
LI NDY C PU Switch Sm art I nstallation an d Use Page 24 3.3 Status display The status displ ay usuall y show s the currentl y selected port. If autoscan m ode i s se lec te d, the se gm en ts w ill illum inat e in s equence in a clockwise di recti on interspersed with a di spl ay of the currentl y sel ected channel.
LI NDY C PU Switch Sm art I nstallation an d Use Page 25 3.4 Key board hotkey contr ol LINDY C PU Sw i tch Sm art can be conveni ently control led by sel ecting channel , autoscan m ode or securi ty l o cki ng from the keyboard. All of the hotkey control com mands are invoked by holdi ng dow n the two hotkeys and then pressing a com mand key.
LI NDY C PU Switch Sm art I nstallation an d Use Page 26 Ex am ples of com m on hotkey sequences (assum i ng CTRL + A LT hotkey opti on): To select channel 2: press ED rel ease ED To ’ tab through’ channels: press ED Y rel ease Y press Y release Y press Y release YED 3.
LI NDY C PU Switch Sm art I nstallation an d Use Page 27 3.6 RS232 contr ol LINDY CPU Sw i tch Sm art can be control led by a rem ote RS232 device. To select a channel the data rate of the sendi ng device m ust be set to 1200 baud, 8 bi ts, no parity and 1 stop bi t.
LI NDY C PU Switch Sm art I nstallation an d Use Page 28 A typical cascade of two LINDY CPU Sw i tch Sm arts 3.8 Sy nchronising LINDY CPU Switch Sm arts for m ultiple v ideo head applications Multipl e LINDY C PU Sw i tch Sm arts m ay be connected together so that they operate in a synchroni sed m anner.
LI NDY C PU Switch Sm art I nstallation an d Use Page 29 channel i f it recei ves the sam e comm and on its seri al i nterface. Consequently, by li nking the seri al i nterfaces a m aster uni t may be m ade to autom atical ly switch a da isy ch ain of s lav ed unit s as sh ow n in t he dia gra m belo w .
LI NDY C PU Switch Sm art I nstallation an d Use Page 30 4. LINDY CP U S w itch Smar t configuration options All the opti ons described i n thi s secti on are entered in LINDY CPU Sw i tch Sm art configure m ode - see secti on 2.6 for instructi ons on entering confi gure m ode.
LI NDY C PU Switch Sm art I nstallation an d Use Page 31 L1 - CPU S witch Sm art onl y locks on to acti ve ports during autoscanni ng (default) L2 - CPU Sw i tch Sm art l o cks on to every port i n tu.
LI NDY C PU Switch Sm art I nstallation an d Use Page 32 The LINDY CPU Sw i tch Sm art supports ‘ Internet Mice ’ that are com pati ble with the M icr os oft In te lliM ous e. Th es e a re f itt ed w ith a w heel or other scroll control and som e ti m es have addi ti onal buttons.
LI NDY C PU Switch Sm art I nstallation an d Use Page 33 again). The fol lowing keyboard hotkey com bi nati ons can be sel ected. These hotkey com bi nati ons are used together with the com m and keys to trigger the requi red CPU Sw itch functi on.
LI NDY C PU Switch Sm art I nstallation an d Use Page 34 connections..
LI NDY C PU Switch Sm art I nstallation an d Use Page 35 F1 - Di spl ay fi rm ware first di git (Note: F1 i s ) fol l owed by NOT O ) F2 - Displ ay firm ware second digit F3 - Di spl ay fi rmw are.
LI NDY C PU Switch Sm art I nstallation an d Use Page 36 4.8 Cascade quer y code The LINDY C PU Sw i tch Sm arts use a speci al ‘ query code ’ to detect whether or not they are connected to another LINDY C PU Sw i tch Sm art. By default your LINDY CPU S w i tch Sm art uses query code AD.
LI NDY C PU Switch Sm art I nstallation an d Use Page 37.
LI NDY C PU Switch Sm art I nstallation an d Use Page 38 4.10 Exit configur e mode W hen you have fini shed configuri ng any specia l opti ons, si m pl y type ‘ E ’ fol l owed by (return) to ex i t configure m ode and return to norm al operati on m ode.
LI NDY C PU Switch Sm art I nstallation an d Use Page 39 A ppendix A . Cable a nd connector specificat ions IMPORTANT NOT E T he m aximu m cable len gths suppor ted va ry widely between devices an d cables.
LI NDY C PU Switch Sm art I nstallation an d Use Page 40 have these DDC li nes connected. Key board an d PS/2 m ice - 6 pin m i ni-DIN m al e connector to 6 pin mini-DIN m al e connector w i th all li nes connected straight through (1-1,2-2 etc.
LI NDY C PU Switch Sm art I nstallation an d Use Page 41 Recom mended cables: 3-in-1 key board, video an d mou se combination cable - For conveni ence, neatness and high vi deo quali ty w e recom m end the LINDY brand 3-in-1 com bi nati on cables.
LI NDY C PU Switch Sm art I nstallation an d Use Page 42 A.4 Flash upgrade cable connection The cable connecti ons show n bel ow are to connect either COM1 or COM 2 of a PC to the LINDY C PU Sw i tch Sm art to al low flash upgrades.
LI NDY C PU Switch Sm art I nstallation an d Use Page 43 A ppendix B. Proble m Solving Problem: Poor vi deo quality with s mear ing fuzziness or ri pple. A c tion: Use sc reened coax ial vi deo cables to connect your devices . Problem: M ouse does not mov e cursor on scr een.
LI NDY C PU Switch Sm art I nstallation an d Use Page 44 A c tion: Change the mous e driv er to a M icros of t mous e driver or take the ac tion recom mended i n section 4.
Een belangrijk punt na aankoop van elk apparaat Lindy LF1TBELRG (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Lindy LF1TBELRG heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Lindy LF1TBELRG vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Lindy LF1TBELRG leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Lindy LF1TBELRG krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Lindy LF1TBELRG bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Lindy LF1TBELRG kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Lindy LF1TBELRG . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.