USA & Canada (800) 421-1587 & (800) 392-0123 (760) 438-7000 - T oll Free FAX (800) 468-1340 www .linearcorp.com AE2000Plus T elephone Entr y & Access Control System PRINTER’S INSTRUCTIONS: INSTR,INSTL,AE2000Plus - LINEAR P/N: 227541 B - INK: BLACK - MA TERIAL: 20 LB.
2 Contents Introduction The Model AE2000Plus T elephone Entr y & Access Control System is designed for use as a primary access control device f or gated communities, parking garages, offi ce b uildings, apartments, dor mitories, hotels/motels, commercial b uildings and recreational facilities.
3 Har dwar e F eatur es ✓ BUILT -IN RADIO RECEIVER Variable gain, high-sensitivity receiver for wireless transmitters ✓ FOUR FORM “C” (N.O. & N.
4 Accessor y Over view PBUS Accessories Sev eral compatib le accessories are availab le to connect to the three 6-wire communications “PBUS” inputs. Up to six PBUS accessor ies can be used with each AE2000Plus unit. AM-RRR R emote Radio R ecei ver For wireless tr ansmitters, connect the Model AM-RRR high-gain superheterodyne UHF receiver .
5 Component Locations OPTIONAL CAME R A DI S PLAY LEFT CA B INET LOCK OPTIONAL PO S TAL LOCK S PEAKE R KEYPAD MIC R OPHONE R ELAY TE R MINAL S WIE G AND INPUT TE R MINAL S TAMPE R S WITCH R ECEIVE R R.
6 Wiring Diagram AE2000PLUS THIS WIRING EXAMPLE SHOWS: DOOR ACCESS WITH A DOOR STRIKE ON RELAY CHANNEL "A" DOOR ACCESS WITH A MAGNETIC LOCK ON RELAY CHANNEL "B" GATE ACCESS WITH A .
7 Impor tant Mounting Requir ements The AE2000Plus T elephone Entr y System can be installed for pub lic or private use. The mounting requirements will vary depending on the installation. Review the f ollowing inf ormation before beginning the installation.
8 Entr y Sys tem Mounting The AE2000Plus cabinet is designed to be mounted three wa ys: • The unit can be mounted directly to a wall or fl at surf ace. • The unit can be mounted recessed into the wall. • The unit can be mounted on a standard gooseneck pedestal.
9 Entr y Sys tem Mounting (Continued) Recessed Mounting The cabinet can be mounted recessed using the accessor y trim-ring (P/N ACP00914). The trim-ring mounts in the wall and the cabinet attaches to the trim-ring. 1. Identify the location of any studs in the wall.
10 Rela y Output Wiring Any of the f our relay outputs channels (A-D) can be used to control access devices on doors or gates . Door or Pedestrian Gate Control 1. Install a low v oltage electric door str ike or magnetic lock as a locking de vice for the door or pedestrian gate.
11 P ower, Bat ter y, & Gr ound Wiring Power Wiring ✦ NO TE: DO NO T APPL Y PO WE R UNTIL THE IN S T ALLA TION I S COMPLETE. TU R N MA S TE R PO WE R S WITCH OFF B EFO R E WI R IN G . 1. Route two wires between the AE2000Plus and the pow er transf or mer .
12 T elephone Wiring For telephone entry and programming, the AE2000Plus connects to a standard telephone line. Impor tant T elephone Wiring Tips • DO NO T ROUTE TELEPHONE AND AC WIRIN G INSIDE THE SAME CONDUIT . Route all telephone wires inside a dedicated conduit that is at least six inches aw ay from any A C line wiring.
13 Optional Color CC T V Camera Linear’ s Model CCM-1 (P/N A CP00904) CCTV camera can be installed inside the AE2000Plus Entr y System. The camera pro vides a video signal for vie wing the area in front of the entry system. The CAMERA connector is used to connect the camera to the AE2000Plus.
14 PBUS Accessories Up to six accessories (keypads , proximity readers , remote receivers) can be connected to the three PBUS input/output por ts. A typical application for a remote k eypad would be to control a second door or gate .
15 Optional Net w ork Connections Linear’ s AE1000Plus, AE2000Plus, & AM3Plus Access Control Systems can be connected together in a network. A network will allow sharing programming and user inf ormation between the systems. Program each unit to a different netw ork Node Address (see Page 19).
16 Optional Net w ork Connections (Continued) Network Confi guration for AccessBase2000 Programming If the system is going to be programmed using Linear’ s AccessBase2000 software, units comm unicate with each other on the network through RS-485 cable connections .
17 NET-A G ND NET- B NETWO R K UNIT " 3 " NET-A G ND NET- B NETWO R K UNIT "4" NET-A G ND NET- B NETWO R K MA S TE R UNIT "1" NET-A G ND NET- B NETWO R K UNIT "2&quo.
18 Sys tem A d jus tments The factory settings are suffi cient f or most installations. The system can be adjusted to customize the installation. System V olume Adjustment The sound lev el of the synthesized voice and ke y beep can be adjusted. 1. Locate the SYSTEM V OLUME adjustment on the CPU circuit board.
19 Internal Contr ols On-board Pushbuttons Sev en pushbuttons are on the main circuit board. Refer to the fi gure for the location of each pushbutton. • UP button adds one to the value on the ST A TUS/PROGRAM displa y . • DOWN b utton subtracts one from value on the ST A TUS/PROGRAM displa y .
20 AE2000Plus Operation Resident Access with an Entr y Code • Residents hav e up to 40 seconds to ke y in their entr y code. • Up to eight seconds are allow ed between each keystrok e. • If the code is entered wrong, press the ke y to reset the ke ypad and re-enter the correct entr y code.
21 17-3/8" 21-1/8" 4" OPTIONAL TRIM RING 15-1/4" 19" 4" AE2000PLUS Dimension Drawing Specifi cations MECHANICAL Case dimensions: 15-1/4” W x 19” H x 4” D ELECTRICA.
22 T r oubleshooting System completely dead 1. No power from tr ansformer . Check v oltage at transf or mer terminals. 2. Check v oltage at AE2000Plus power terminal strip. Buzz on speaker 1. Check f or 24 volt A C power shorted to wiring conduit. 2. Check f or telephone line shor ted to ground.
23 Linear Limited W ar rant y This Linear product is warranted against def ects in material and workmanship for tw enty-four (24) months. This warranty e xtends only to wholesale customers who buy direct from Linear or through Linear’ s normal distr ibution channels.
Copyright © 2008 Linear LLC 227541 B.
Een belangrijk punt na aankoop van elk apparaat Linear AE2000PLUS (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Linear AE2000PLUS heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Linear AE2000PLUS vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Linear AE2000PLUS leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Linear AE2000PLUS krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Linear AE2000PLUS bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Linear AE2000PLUS kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Linear AE2000PLUS . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.