LRA Linear Residential Actuator Installation Guide PRINTER’S INSTRUCTIONS: INSTR,INSTL,LRA - LINEAR P/N: 228158 X12 - INK: BLACK - MA TERIAL: 20 LB. MEAD BOND - SIZE: 8.
LRA Linear Residential Actuator Installation Guide - 2 - 228158 Revision X13 2-3-2009 T able of Contents Pre-installation Information .................................. 1 B e f o r e Y o u B e g i n . . . ...................................... 1 Alwa ys Check the Gate’ s Action .
LRA Linear Residential Actuator Installation Guide - 1 - 228158 Revision X13 2-3-2009 Pre-installation Information Before Y ou Begin... Bef ore unpac king, inspect the carton for e xterior damage. If you find damage, advise the deliv er y carrier of a potential claim.
LRA Linear Residential Actuator Installation Guide - 2 - 228158 Revision X13 2-3-2009 Linear Actuator Operator Overview The Model LRA Residential Linear Actuator is designed to open and close a light-duty residential s wing gate. The operator can be used in left-hand or right-hand swing gate installations on gates weighing up to 600 pounds .
LRA Linear Residential Actuator Installation Guide - 3 - 228158 Revision X13 2-3-2009 Gate Lay out Illustration ENTR Y GATE FULLY CLOSED GATE FULLY OPEN LEAVE SLAC K IN CABLE TO ALLOW F O R GATE SWIN .
LRA Linear Residential Actuator Installation Guide - 4 - 228158 Revision X13 2-3-2009 Mounting Brack et Installation Examine Figure 2 f or details of the required mounting locations f or the two brack ets.
LRA Linear Residential Actuator Installation Guide - 5 - 228158 Revision X13 2-3-2009 Operator Setup Operator Mounting The operator mounts on the post brack et pin and into the gate brac ket b ushing. Refer to Figure 5. With the gate closed, carefully position the operator over the mounting 1.
LRA Linear Residential Actuator Installation Guide - 6 - 228158 Revision X13 2-3-2009 Operator Setup (Continued) Limit Switch Adjustment The open and close limit switches are adjustable by sliding them on the operator’ s frame . Sliding either s witch closer to the center of the operator decreases the gate tra vel.
LRA Linear Residential Actuator Installation Guide - 7 - 228158 Revision X13 2-3-2009 Controller Features SHADOW/RESET PROGRAMMING BUTTONS POWE R INDICATORS DISPLAY WHIP ANTENNA OPERATION BUTTONS OPER.
LRA Linear Residential Actuator Installation Guide - 8 - 228158 Revision X13 2-3-2009 Indicator Descriptions INDICA T OR DEFINITION INDICA TION WHEN LIT DURING NORMAL OPERA TION INDICA TION WHEN LIT D.
LRA Linear Residential Actuator Installation Guide - 9 - 228158 Revision X13 2-3-2009 T erminal Descriptions TERMINAL GROUP FUNCTION A C N 24 VOL T INPUT F ACT OR Y CONNECTED TO 24 V AC FR OM TRANSFORMER OR 24 VDC FROM CONTINUOUS DUTY DC SUPPL Y . AC DC - A CCESSOR Y POWER PRO VIDES 24 VOL T DC POWER FOR A CCESSORIES.
LRA Linear Residential Actuator Installation Guide - 10 - 228158 Revision X13 2-3-2009 Operator Accessor y Connections 3-BUTTON ST ATIO N KEYSWITC H FIRE ACCESS SWITCH SINGLE-CHAN NEL RADIO RECEIVER W.
LRA Linear Residential Actuator Installation Guide - 11 - 228158 Revision X13 2-3-2009 Basic Controller Programming Progr amming Overview The Controller can be programmed with v arious options for the operator . The programming fields are defined as “functions” that hav e “options”.
LRA Linear Residential Actuator Installation Guide - 12 - 228158 Revision X13 2-3-2009 Basic Controller Programming (Cont.) Run Alarm and Pre-start Alarm The f actor y def ault is Run Alarm on and a 3-second Pre-star t Alarm. The operator’ s beeper will sound 3 seconds before the operator star ts.
LRA Linear Residential Actuator Installation Guide - 13 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming Entering Advanced Progr amming Mode T o access and program the Advanced Programming functions, f or each programming session, Adv anced Programming must be enab led.
LRA Linear Residential Actuator Installation Guide - 14 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming (Cont.) Auxiliary Relay Mode The Auxiliary Relay has nor mally open and nor mally closed contacts. The f actor y setting disables the A uxiliar y Relay .
LRA Linear Residential Actuator Installation Guide - 15 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming (Cont.) Soft Start/Stop Duration This function causes the operator to star t and stop the DC motor slowly reducing gate wear and tear (at the full open or closed positions only).
LRA Linear Residential Actuator Installation Guide - 16 - 228158 Revision X13 2-3-2009 Advanced Controller Progr amming (Cont.) Radio Enable The Controller contains a built-in MegaCode ® radio receiver to allow activation from up to 40 access control transmitters and two Model MGT (gate edge) transmitters.
LRA Linear Residential Actuator Installation Guide - 17 - 228158 Revision X13 2-3-2009 Loop Lay out Illustration 2" 3/8" 4 FT. MINIMU M USE RELIEF CUT S AT CORNER S TWIST WIRE FROM END OF LOOPS BACK TO OPERATOR AT LEAST SIX TIMES PE R FOOT 2" MAX.
LRA Linear Residential Actuator Installation Guide - 18 - 228158 Revision X13 2-3-2009 Safety Edge Lay out Illustration RECEIVER FOR GATE EDGE TRANS MITTER BUILT INTO CONTROLLER GATE EDGE TRANSMITTER #1 SEPARATE PEDESTRIAN GATE REQUIRED 7FT.
LRA Linear Residential Actuator Installation Guide - 19 - 228158 Revision X13 2-3-2009 Photoey e Installation Illustration SEPARATE PEDESTRIAN GATE REQ UIRED 7 FT.
LRA Linear Residential Actuator Installation Guide - 20 - 228158 Revision X13 2-3-2009 Dual Gate Installations T wo oper ato rs can be used in du al gat e inst all ati ons . T he ope ra tor s communicate with each other through the 3-wire COMM LINK terminals.
LRA Linear Residential Actuator Installation Guide - 21 - 228158 Revision X13 2-3-2009 Operation Indications During nor mal oper ation, the Controller’ s displa ys will indicate current operating conditions and status .
LRA Linear Residential Actuator Installation Guide - 22 - 228158 Revision X13 2-3-2009 T roubleshooting Contacting T echnical Support F or technical questions regarding Linear gate operators, contact the T echnical Ser vices Depar tment at: 1-800-421-1587 from 6:30 AM to 4:30 PM P acific time Operator fails to start A.
LRA Linear Residential Actuator Installation Guide - 23 - 228158 Revision X13 2-3-2009 Model LRA Replacement P arts HARDWARE KI T POST BRACKET KI T GATE BRACKE T KI LIMIT SWITCH KIT T WORM DRIVE CA P .
LRA Linear Residential Actuator Installation Guide - 24 - 228158 Revision X13 2-3-2009 Prev entative Maintenance General Linear gate operators are designed for many y ears of trouble-free operation and, under recommended operating conditions, will require only minimal maintenance.
LRA Linear Residential Actuator Installation Guide - 25 - 228158 Revision X13 2-3-2009.
LRA Linear Residential Actuator Installation Guide - 26 - 228158 Revision X13 2-3-2009 Gate Operator Installation Checklist ❑ ❑ 1. The gate has been chec ked to make sure it is le vel and mov es freely in both directions.
Een belangrijk punt na aankoop van elk apparaat Linear LRA (of zelfs voordat je het koopt) is om de handleiding te lezen. Dit moeten wij doen vanwege een paar simpele redenen:
Als u nog geen Linear LRA heb gekocht dan nu is een goed moment om kennis te maken met de basisgegevens van het product. Eerst kijk dan naar de eerste pagina\'s van de handleiding, die je hierboven vindt. Je moet daar de belangrijkste technische gegevens Linear LRA vinden. Op dit manier kan je controleren of het apparaat aan jouw behoeften voldoet. Op de volgende pagina's van de handleiding Linear LRA leer je over alle kenmerken van het product en krijg je informatie over de werking. De informatie die je over Linear LRA krijgt, zal je zeker helpen om een besluit over de aankoop te nemen.
In een situatie waarin je al een beziter van Linear LRA bent, maar toch heb je de instructies niet gelezen, moet je het doen voor de hierboven beschreven redenen. Je zult dan weten of je goed de alle beschikbare functies heb gebruikt, en of je fouten heb gemaakt die het leven van de Linear LRA kunnen verkorten.
Maar de belangrijkste taak van de handleiding is om de gebruiker bij het oplossen van problemen te helpen met Linear LRA . Bijna altijd, zal je daar het vinden Troubleshooting met de meest voorkomende storingen en defecten #MANUAl# samen met de instructies over hun opplosinge. Zelfs als je zelf niet kan om het probleem op te lossen, zal de instructie je de weg wijzen naar verdere andere procedure, bijv. door contact met de klantenservice of het dichtstbijzijnde servicecentrum.